44 matches found
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-26872)
RDMA/srpt: use-after-free Write in srptrefreshport. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503489; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-27047)
Vulnerablity in Linux kernel: net: phy: phygetinternaldelay accessing an empty array The phygetinternaldelay function could try to access to an empty array in the case that the driver is calling phygetinternaldelay without defining delayvalues and rx-internal- delay-ps or tx-internal-delay-ps is...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-27437)
In the Linux kernel, the following vulnerability has been resolved: vfio/pci: Disable auto-enable of exclusive INTx IRQ Currently for devices requiring masking at the irqchip for INTx, ie. devices without DisINTx support, the IRQ is enabled in requestirq and subsequently disabled as necessary to...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-43890)
tracing: vulnerability due to an overflow in getfreeelt, which could lead to infinite loops and CPU hangs when the tracing map becomes full. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC Devices Use After Free (CVE-2024-23848)
In the Linux kernel through 6.7.1, there is a use-after-free in cecqueuemsgfh, related to drivers/media/cec/core/cec-adap.c and drivers/media/cec/core/cec-api.c. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
Siemens SIMATIC Devices Use After Free (CVE-2024-27395)
In the Linux kernel, the following vulnerability has been resolved: net: openvswitch: Fix Use-After-Free in ovsctexit Since kfreercu, which is called in the hlistforeachentryrcu traversal of ovsctlimitexit, is not part of the RCU read critical section, it is possible that the RCU grace period wil...
Siemens SIMATIC Devices Integer Overflow or Wraparound (CVE-2024-58017)
printk: Fix signed integer overflow when defining LOGBUFLENMAX This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503397; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-42281)
In the Linux kernel, the following vulnerability has been resolved: bpf: Fix a segment issue when downgrading gsosize Linearize the skb when downgrading gsosize because it may trigger a BUGON later when the skb is segmented as described in 1,2. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC Devices Use After Free (CVE-2024-35955)
kprobes: Fix possible use-after-free issue on kprobe registration This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503699; scriptversion"1.2";...
Siemens SIMATIC Devices NULL Pointer Dereference (CVE-2025-21844)
smb: client: Add check for nextbuffer in receiveencryptedstandard This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503639; scriptversion"1.2";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-46744)
In the Linux kernel, the following vulnerability has been resolved: Squashfs: sanity check symbolic link size. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens SIMATIC Devices Improper Input Validation (CVE-2025-21704)
usb: cdc-acm: Check control transfer buffer size before access This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503558; scriptversion"1.2";...
Siemens SIMATIC Devices NULL Pointer Dereference (CVE-2024-36902)
Vulnerability in Linux kernel: ipv6: fib6rules: avoid possible NULL dereference in fib6ruleaction syzbot is able to trigger the following crash 1, caused by unsafe ip6dstidev use. Indeed ip6dstidev can return NULL, and must always be checked. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC Devices Incorrect Calculation of Buffer Size (CVE-2024-42259)
In the Linux kernel, the following vulnerability has been resolved: drm/i915/gem: Fix Virtual Memory mapping boundaries calculation Calculating the size of the mapped area as the lesser value between the requested size and the actual size does not consider the partial mapping offset. This can cau...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-26642)
In the Linux kernel, the following vulnerability has been resolved: netfilter: nftables: disallow anonymous set with timeout flag This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC Devices Improper Validation of Array Index (CVE-2024-35905)
In the Linux kernel, the following vulnerability has been resolved: bpf: Protect against int overflow for stack access size This patch re-introduces protection against the size of access to stack memory being negative; the access size can appear negative as a result of overflowing its signed int...
Siemens SIMATIC Devices Out-of-bounds Write (CVE-2024-36916)
In the Linux kernel, the following vulnerability has been resolved: blk-iocost: avoid out of bounds shift UBSAN catches undefined behavior in blk-iocost, where sometimes iocg-delay is shifted right by a number that is too large, resulting in undefined behavior on some architectures. 186.556576...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Uncontrolled Resource Consumption (CVE-2024-47710)
sockmap: vulnerability result of adding a condresched in sockhashfree to prevent CPU soft lockups when destroying maps with a large number of buckets. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens SIMATIC Devices Improper Input Validation (CVE-2025-21653)
netsched: clsflow: validate TCAFLOWRSHIFT attribute This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503380; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2025-21826)
netfilter: nftables: reject mismatching sum of fieldlen with set key length. The field length description provides the length of each separated key field in the concatenation, each field gets rounded up to 32-bits to calculate the pipapo rule width from pipapoinit. The set key length provides the...