Lucene search
+L

20976 matches found

ATTACKERKB
ATTACKERKB
added 2026/01/26 5:49 p.m.11 views

CVE-2026-24435

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 implement an insecure Cross-Origin Resource Sharing CORS policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: in combination with Access-Control-Allow-Credentials: true, allowing...

7.1CVSS5.9AI score0.00219EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2026/01/26 5:49 p.m.51 views

CVE-2026-24435 Tenda W30E V2 Permissive CORS Allows Cross-origin Data Access

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 implement an insecure Cross-Origin Resource Sharing CORS policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: in combination with Access-Control-Allow-Credentials: true, allowing...

7.1CVSS0.00219EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/01/26 5:48 p.m.8 views

CVE-2026-24439

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...

2.1CVSS5.9AI score0.00175EPSS
SaveExploits0References3
CVE
CVE
added 2026/01/26 5:48 p.m.23 views

CVE-2026-24439

The CVE-2026-24439 entry concerns Shenzhen Tenda W30E V2 firmware up to and including V16.01.0.19(5037) that lacks the X-Content-Type-Options: nosniff header on web management interfaces. This omission can allow browsers that perform MIME sniffing to misinterpret attacker-influenced responses as ...

6.5CVSS5.9AI score0.00175EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2026/01/26 5:48 p.m.48 views

CVE-2026-24439 Tenda W30E V2 Lacks X-Content-Type-Options Header

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...

2.1CVSS0.00175EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/01/26 5:48 p.m.10 views

CVE-2026-24439 Tenda W30E V2 Lacks X-Content-Type-Options Header

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...

2.1CVSS5.9AI score0.00175EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/01/26 5:48 p.m.11 views

EUVD-2026-4674

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...

2.1CVSS5.9AI score0.00175EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/01/26 5:46 p.m.6 views

CVE-2026-24432 Tenda W30E V2 Missing CSRF Protections for Administrative Actions

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 lack cross-site request forgery CSRF protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered b...

5.1CVSS5.9AI score0.00112EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/01/26 5:46 p.m.12 views

EUVD-2026-4672

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 lack cross-site request forgery CSRF protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered b...

5.1CVSS5.9AI score0.00112EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2026/01/26 5:46 p.m.46 views

CVE-2026-24432 Tenda W30E V2 Missing CSRF Protections for Administrative Actions

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 lack cross-site request forgery CSRF protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered b...

5.1CVSS0.00112EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/01/26 5:46 p.m.6 views

CVE-2026-24432

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 lack cross-site request forgery CSRF protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered b...

5.1CVSS5.9AI score0.00112EPSS
SaveExploits0References3
CVE
CVE
added 2026/01/26 5:46 p.m.28 views

CVE-2026-24432

Shenzhen Tenda W30E V2 firmware up to 16.01.0.19(5037) lacks CSRF protections on administrative endpoints, including password changes. An attacker could craft requests that, when triggered by an authenticated user’s browser, modify admin passwords and other settings. Root cause: missing CSRF prot...

5.1CVSS5.9AI score0.00112EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2026/01/26 5:40 p.m.49 views

CVE-2026-24433 Tenda W30E V2 Stored XSS via Username Field

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users...

5.1CVSS0.00191EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/01/26 5:40 p.m.16 views

EUVD-2026-4662

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users...

5.1CVSS5.8AI score0.00191EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/01/26 5:40 p.m.5 views

CVE-2026-24433

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users...

5.1CVSS5.8AI score0.00191EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
added 2026/01/26 5:40 p.m.4 views

CVE-2026-24433 Tenda W30E V2 Stored XSS via Username Field

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users...

5.1CVSS5.8AI score0.00191EPSS
SaveExploits0References2
CVE
CVE
added 2026/01/26 5:40 p.m.40 views

CVE-2026-24433

CVE-2026-24433 affects Shenzhen Tenda W30E V2 firmware

5.4CVSS5.8AI score0.00191EPSS
SaveExploits0References2Affected Software1
ATTACKERKB
ATTACKERKB
added 2026/01/26 5:40 p.m.5 views

CVE-2026-24431

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials...

7.1CVSS5.9AI score0.00197EPSS
SaveExploits0References3
CVE
CVE
added 2026/01/26 5:40 p.m.32 views

CVE-2026-24431

The CVE-2026-24431 entry concerns Shenzhen Tenda W30E V2 devices. Concrete details from connected sources show that firmware versions up to and including V16.01.0.19(5037) store user account passwords in plaintext in the administrative web interface, allowing any user with access to affected mana...

7.1CVSS5.9AI score0.00197EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2026/01/26 5:40 p.m.42 views

CVE-2026-24431 Tenda W30E V2 Web UI Reveals Passwords in Cleartext

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials...

7.1CVSS0.00197EPSS
SaveExploits0References2
Rows per page
Query Builder