Positive Technologies
Positive Technologies
added 2026/02/08 12:00 a.m.19 views

PT-2026-7012

Name of the Vulnerable Software and Affected Versions Tenda RX3 version 16.03.13.11 Description A stack-based buffer overflow exists in Tenda RX3 version 16.03.13.11. The issue is located in the file /goform/fast setting wifi set. Manipulation of the ssid 5g argument can trigger the overflow. Thi...

9CVSS8.5AI score0.00573EPSS
SaveExploits1References7
CNNVD
CNNVD
added 2026/02/08 12:00 a.m.17 views

Tenda RX3 安全漏洞

The Tenda RX3 is a dual-band WiFi 6 home router produced by the Chinese company Tenda. It is used for network coverage in households and supports high-speed wireless connections. The version 16.03.13.11 of the Tenda RX3 contains a security vulnerability. This vulnerability stems from incorrect...

9CVSS7.7AI score0.00573EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
added 2026/02/08 12:00 a.m.11 views

PT-2026-6964

Name of the Vulnerable Software and Affected Versions Tenda TX9 versions up to 22.03.02.10 multi Description A flaw exists in Tenda TX9 devices up to version 22.03.02.10 multi. The issue is due to a buffer overflow in the sub 42D03C function within the /goform/SetStaticRouteCfg file when handling...

9CVSS5.8AI score0.00762EPSS
SaveExploits1References12
Positive Technologies
Positive Technologies
added 2026/02/08 12:00 a.m.32 views

PT-2026-6985

Name of the Vulnerable Software and Affected Versions Tenda AC8 version 16.03.33.05 Description A buffer overflow issue exists in the fromSetWifiGusetBasic function within the /goform/WifiGuestSet file of the httpd component. The shareSpeed argument can be manipulated to trigger this issue,...

9CVSS5.8AI score0.00646EPSS
SaveExploits1References8
Positive Technologies
Positive Technologies
added 2026/02/08 12:00 a.m.20 views

PT-2026-6986

Name of the Vulnerable Software and Affected Versions Tenda AC8 version 16.03.33.05 Description A buffer overflow issue exists in the Embedded Httpd Service component of Tenda AC8. The flaw is located in the file '/goform/fast setting wifi set' and is triggered by manipulating the timeZone...

9CVSS5.5AI score0.00646EPSS
SaveExploits1References8
Positive Technologies
Positive Technologies
added 2026/02/08 12:00 a.m.21 views

PT-2026-6967

Name of the Vulnerable Software and Affected Versions Tenda TX9 versions up to 22.03.02.10 multi Description A flaw exists in the Tenda TX9 device, specifically within the sub 4223E0 function located in the /goform/setMacFilterCfg file. Manipulation of the deviceList argument can trigger a buffer...

9CVSS6AI score0.00762EPSS
SaveExploits1References13
NVD
NVD
added 2026/02/07 10:16 p.m.15 views

CVE-2026-25857

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality formSetWanDiag. The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without...

8.8CVSS0.02929EPSS
SaveExploits1References3
OSV
OSV
added 2026/02/07 10:16 p.m.14 views

CVE-2026-25857

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality formSetWanDiag. The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without...

8.8CVSS6.2AI score0.02929EPSS
SaveExploits1References3
Vulnrichment
Vulnrichment
added 2026/02/07 9:41 p.m.6 views

CVE-2026-25857 Tenda G300-F Command Injection via formSetWanDiag

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality formSetWanDiag. The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without...

8.6CVSS6.2AI score0.02929EPSS
SaveExploits1References3
Cvelist
Cvelist
added 2026/02/07 9:41 p.m.46 views

CVE-2026-25857 Tenda G300-F Command Injection via formSetWanDiag

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality formSetWanDiag. The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without...

8.6CVSS0.02929EPSS
SaveExploits1References3
CVE
CVE
added 2026/02/07 9:41 p.m.52 views

CVE-2026-25857

CVE-2026-25857 affects the Tenda G300-F router. Affected firmware: versions prior to 16.01.14.2. The issue lies in the WAN diagnostic function formSetWanDiag, which builds a shell command invoking curl and injects attacker-controlled input without proper sanitization. This allows a remote attacke...

8.8CVSS6.2AI score0.02929EPSS
SaveExploits1References3Affected Software1
ATTACKERKB
ATTACKERKB
added 2026/02/07 9:41 p.m.7 views

CVE-2026-25857

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality formSetWanDiag. The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without...

8.6CVSS6.2AI score0.02929EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
added 2026/02/07 12:00 a.m.15 views

PT-2026-6932

Name of the Vulnerable Software and Affected Versions Tenda G300-F router firmware versions prior to 16.01.14.2 Description The Tenda G300-F router firmware contains an OS command injection issue in the WAN diagnostic functionality, specifically within the formSetWanDiag function. The software...

8.6CVSS6AI score0.02929EPSS
SaveExploits1References6
CNNVD
CNNVD
added 2026/02/07 12:00 a.m.19 views

Tenda G300-F 操作系统命令注入漏洞

The Tenda G300-F is a VPN router produced by the Chinese company Tenda. Versions of the Tenda G300-F starting from 16.01.14.2 and earlier have a vulnerability related to operating system command injection. This vulnerability stems from the presence of OS command injection in the WAN diagnostic...

8.8CVSS6.1AI score0.02929EPSS
SaveExploits1References4
CNVD
CNVD
added 2026/02/05 12:00 a.m.11 views

Tenda D301 and Tenda D151 Access Control Error Vulnerabilities

Tenda D301 is a wireless router.Tenda D151 is a wireless router. An access control error vulnerability exists in the Tenda D301 and Tenda D151 that stems from the presence of an unauthenticated configuration download on the /goform/getimage endpoint, which can be exploited by an attacker to cause...

8.7CVSS6AI score0.0065EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2026/02/04 7:27 p.m.13 views

CVE-2026-24434

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrat...

6.5CVSS5.5AI score0.00152EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2026/02/04 7:27 p.m.10 views

CVE-2026-24426

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser...

6.1CVSS5.6AI score0.00195EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2026/02/04 7:27 p.m.11 views

CVE-2026-24427

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack...

6.8CVSS5.4AI score0.00123EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2026/02/04 7:27 p.m.15 views

CVE-2026-24441

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material...

8.2CVSS5.5AI score0.00215EPSS
SaveExploits0References1
NVD
NVD
added 2026/02/03 8:15 p.m.11 views

CVE-2026-24441

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material...