5667 matches found
CVE-2021-22803: Unrestricted Upload of File with Dangerous Type
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24310
CVE-2022-24310 affects Schneider Electric IGSS Data Server (v15.0.0.22020 and prior). Root cause: CWE-190 integer overflow/wraparound that can cause a heap-based buffer overflow, enabling denial of service and potentially remote code execution when processing multiple specially crafted messages. ...
CVE-2022-24317: Missing Authorization
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316: Improper Initialization
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24315: Out-of-bounds Read
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24314: Out-of-bounds Read
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24311: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...
CVE-2022-24313: Buffer Copy without Checking Size of Input
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...
CVE-2022-24312: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
PT-2022-16601
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions prior to 15.0.0.22020 Description A Missing Authorization issue exists that could cause information exposure when an attacker sends a specific message. Recommendations For versions prior ...
PT-2022-16600
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A CWE-665: Improper Initialization issue exists, potentially causing information exposure when an attacker sends a specially crafted message...
Interactive Graphic SCADA System Data Server Buffer Error Vulnerability
The Schneider Electric Interactive Graphical Scada System is a Scada system for monitoring industrial processes from Schneider Electric, France. An out-of-bounds read vulnerability exists in the Schneider Electric Interactive Graphical Scada System, which can be exploited by an attacker to cause ...
CVE-2022-24310: Integer Overflow or Wraparound
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...
PT-2022-2281
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by adding to the end of the file or create a new file in the context of the Da...
PT-2022-1815
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by inserting at the beginning of the file or create a new file in the context ...
PT-2022-2282
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is caused by an integer overflow or wraparound, leading to a heap-based buffer overflow. This could allow a remote attacker to cause a denial...