844 matches found
PT-2025-1103 · Microsoft · Windows App Package Installer +1
Name of the Vulnerable Software and Affected Versions: Windows App Package Installer affected versions not specified Description: The issue is related to weaknesses in the authorization procedure of the Windows App Package Installer, allowing an attacker to elevate their privileges. This can be...
PT-2025-1172 · Microsoft · Windows Digital Media +1
Name of the Vulnerable Software and Affected Versions: Windows Digital Media affected versions not specified Description: The issue is related to a component of the Windows operating system, specifically Digital Media, and involves a memory reading error beyond the allowed range. This can...
PT-2025-1162 · Microsoft · Windows Digital Media +1
Name of the Vulnerable Software and Affected Versions: Windows Digital Media affected versions not specified Description: The issue is related to a component of the Windows operating system, specifically Digital Media, and involves a memory reading error beyond the allowed range. This can...
PT-2025-1169 · Microsoft · Windows Digital Media +1
Name of the Vulnerable Software and Affected Versions: Windows Digital Media affected versions not specified Description: The issue is related to a component of the Windows operating system, specifically Digital Media, and involves a memory reading error beyond the allowed range. This can be...
PT-2025-1386 · Opsview · Opsview Monitor Agent
Name of the Vulnerable Software and Affected Versions: Opsview Monitor Agent version 6.8 Description: A problem was discovered in Opsview Monitor Agent where an unauthenticated remote attacker can call check nrpe against affected targets, specifying known NRPE plugins. In default installations,...
CVE-2024-52869
Certain Teradata account-handling code through 2024-11-04, used with SUSE Enterprise Linux Server, mismanages groups. Specifically, when there is an operating system move from SUSE Enterprise Linux Server SLES 12 Service Pack SP 2 or 3 to SLES 15 SP2 on Teradata Database systems, some...
CVE-2024-9154
A code injection vulnerability in HMS Networks Ewon Flexy 205 allows executing commands on system level on the device. This issue affects Ewon Flexy 205: through 14.8s0 2633...
The vulnerability of the EVGA Precision X1 system’s software relates to the unsafe use of privileges, allowing a violator to increase their privileges.
The vulnerability of the EVGA Precision X1 system’s software relates to insecure handling of privileges. Exploiting this vulnerability could allow an attacker to elevate their privileges to “NT AUTHORITY\SYSTEM” by associating \Device\PhysicalMemory with the calling process...
CVE-2024-11947
GFI Archiver Core Service Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of GFI Archiver. Authentication is required to exploit this vulnerability. The specific flaw exists withi...
The vulnerability of the Windows Common Log File System (CLFS) driver in Windows operating systems allows a hacker to elevate their privileges to the SYSTEM level.
The vulnerability of the Windows Common Log File System CLFS driver in Windows operating systems is related to buffer overflows in dynamic memory. Exploiting this vulnerability can allow an attacker to elevate their privileges to the SYSTEM level...
CVE-2024-55544
Missing input validation in the ORing IAP-420 web-interface allows authenticated Command Injections on OS level.This issue affects IAP-420 version 2.01e and below...
CVE-2024-11220
A local low-level user on the server machine with credentials to the running OAS services can create and execute a report with an rdlx file on the server system itself. Any code within the rdlx file of the report executes with SYSTEM privileges, resulting in privilege escalation...
CVE-2024-7240
F-Secure Total Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of F-Secure Total. User interaction on the part of an administrator is required to exploit this vulnerability. The specific flaw exist...
CVE-2024-6260
Malwarebytes Antimalware Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Malwarebytes Antimalware. An attacker must first obtain the ability to execute low-privileged code on the target system i...
CVE-2023-20036
A vulnerability in the web UI of Cisco IND could allow an authenticated, remote attacker to execute arbitrary commands with administrative privileges on the underlying operating system of an affected device. This vulnerability is due to improper input validation when uploading a Device Pack. An...
CVE-2024-20119
In mms, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS09062301; Issue ID: MSV-1620...
CVE-2024-20110
In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS09065887; Issue ID: MSV-1762...
The vulnerability of the CLFS driver for Microsoft Windows operating systems allows a hacker to gain increased privileges.
The vulnerability of the CLFS driver in Microsoft Windows operating systems is related to errors in privilege management. Exploiting this vulnerability can allow an attacker to elevate their privileges to the SYSTEM level using a specially crafted blk-file...
CVE-2024-47902
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber All versions V8.2.12, InterMesh 7707 Fire Subscriber All versions V7.2.12 only if the IP interface is enabled which is not the default configuration. The web server of affected devices does not authenticate GET requests...
CVE-2024-47902
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber All versions V8.2.12, InterMesh 7707 Fire Subscriber All versions V7.2.12 only if the IP interface is enabled which is not the default configuration. The web server of affected devices does not authenticate GET requests...