Lucene search
+L

6833 matches found

Packet Storm
Packet Storm
•added 2013/08/16 12:00 a.m.•53 views

IBM 1754 GCM16 1.18.0.22011 Command Execution

I. Product description The IBM 1754 GCM family provides KVM over IP and serial console management technology in a single appliance. II. Vulnerability information Impact: Command execution Remotely exploitable: yes CVE: 2013-0526 CVS Score: 8.5 III. Vulnerability details GCM16 v.1.18.0.22011 and...

8.5CVSS0.06069EPSS
SaveExploits3
Tenable Nessus
Tenable Nessus
•added 2013/08/13 12:00 a.m.•227 views

HP Switch Identification

The remote host is an HP switch. It is possible to read the model, serial number, and/or software version by connecting to the switch via SSH or by using SNMP. TRUSTED...

5.5AI score
SaveExploits0
Prion
Prion
•added 2013/06/20 3:55 p.m.•27 views

Heap overflow

The HTTP module in the 1 Branch Intelligent Management System BIMS and 2 web management components on Huawei AR routers and S2000, S3000, S3500, S3900, S5100, S5600, S7800, and S8500 switches does not check whether HTTP data is longer than the value of the Content-Length field, which allows remot...

10CVSS8.5AI score0.0167EPSS
SaveExploits0References1Affected Software18
Prion
Prion
•added 2013/06/20 3:55 p.m.•20 views

Information disclosure

The firewall module on the Huawei Quidway Service Process Unit SPU board S7700, S9300, and S9700 on Huawei Campus Switch devices allows remote authenticated users to obtain sensitive information from the high-priority security zone by leveraging access to the low-priority security zone...

3.5CVSS6.4AI score0.00622EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
•added 2013/06/20 3:00 p.m.•32 views

CVE-2013-4628

The firewall module on the Huawei Quidway Service Process Unit SPU board S7700, S9300, and S9700 on Huawei Campus Switch devices allows remote authenticated users to obtain sensitive information from the high-priority security zone by leveraging access to the low-priority security zone...

5.9AI score0.00622EPSS
SaveExploits0References1
CVE
CVE
•added 2013/06/20 3:00 p.m.•64 views

CVE-2013-4628

The CVE-2013-4628 entry describes an information-disclosure flaw in Huawei Campus Switch devices (Quidway SPU boards S7700, S9300, S9700). The firewall module can allow remote authenticated users to access sensitive information in the high-priority security zone by leveraging access to the low-pr...

3.5CVSS6.1AI score0.00622EPSS
SaveExploits0References1Affected Software3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/06/20 12:00 a.m.•11 views

CVE-2013-4628: Exposure of Sensitive Information to an Unauthorized Actor

The firewall module on the Huawei Quidway Service Process Unit SPU board S7700, S9300, and S9700 on Huawei Campus Switch devices allows remote authenticated users to obtain sensitive information from the high-priority security zone by leveraging access to the low-priority security zone...

3.5CVSS5.8AI score0.00622EPSS
SaveExploits0References2
OpenVAS
OpenVAS
•added 2013/06/18 12:00 a.m.•32 views

Debian Security Advisory DSA 2628-1 (nss-pam-ldapd - buffer overflow)

Garth Mollett discovered that a file descriptor overflow issue in the use of FDSET in nss-pam-ldapd, which provides NSS and PAM modules for using LDAP as a naming service, can lead to a stack-based buffer overflow. An attacker could, under some circumstances, use this flaw to cause a process that...

6.8CVSS0.5AI score0.03582EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2013/05/24 8:00 p.m.•40 views

CVE-2013-3633

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The user privileges for the web interface are only...

6.6AI score0.01197EPSS
SaveExploits0References1
CVE
CVE
•added 2013/05/24 8:00 p.m.•71 views

CVE-2013-3633

Siemens SCALANCE X-200 and X-200IRT switches are affected by two related vulnerabilities (CVE-2013-3633 and CVE-2013-3634). The root cause is that web interface user privileges are enforced only on the client side and not properly verified on the server side (privilege escalation), and the SNMPv3...

8CVSS6.8AI score0.01197EPSS
SaveExploits0References1Affected Software7
Cvelist
Cvelist
•added 2013/05/23 3:00 p.m.•40 views

CVE-2012-6554

functions/htmltotext.php in the Chat module before 1.5.2 for activeCollab allows remote authenticated users to execute arbitrary PHP code via the messagemessagetext parameter to chat/addmessag, which is not properly handled when executing the pregreplace function with the eval switch...

7.3AI score0.16701EPSS
SaveExploits3References6
Veeam
Veeam
•added 2013/05/21 12:00 a.m.•29 views

No network data available for ESX(i) hosts

Challenge SCOM shows the following alert: VP510 No metrics obtained for ESX hosts, failed to process performance or configuration data for hosts Under SCOM Monitoring - Veeam for Vmware- vSphere Host- Performance views, performance counters for hosts actually exist and show all data except for th...

6.8AI score
SaveExploits0
Huawei
Huawei
•added 2013/05/16 12:00 a.m.•31 views

Security Advisory-The Firewall Module of SPU Board Information Leakage Vulnerability of Huawei Campus Switch

The Service Process Unit SPU is the value-added service card of the Switch. SPU provides services such as load balancing, firewall, Network Address Translation NAT, IP Security IPSec, and NetStream. It mainly be deployed in network of carrier and enterprise customers, and provides network securit...

6.3AI score
SaveExploits0Affected Software3
Zero Day Initiative
Zero Day Initiative
•added 2013/04/09 12:00 a.m.•127 views

Cisco IOS Smart Install Configuration File Upload Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Cisco IOS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Smart Install client. A specially crafted packet can be sent to the SMI IBC server to...

7.8CVSS3.1AI score0.01328EPSS
SaveExploits0References1
CVE
CVE
•added 2013/03/28 11:00 p.m.•63 views

CVE-2012-5216

HP ProCurve 1700 series switches (1700-8 J9079A and 1700-24 J9080A) are affected by a cross-site request forgery (CSRF) vulnerability. The issue allows an attacker to hijack the authenticated session of a user who views a malicious page while logged in, potentially changing product settings. Publ...

6.8CVSS7.3AI score0.01485EPSS
SaveExploits0References2Affected Software3
Cvelist
Cvelist
•added 2013/03/07 8:00 p.m.•34 views

CVE-2013-1154

The Cisco Small Business 200 Series Smart Switch 1.2.7.76 and earlier, Small Business 300 Series Managed Switch 1.2.7.76 and earlier, and Small Business 500 Series Stackable Managed Switch 1.2.7.76 and earlier allow remote attackers to cause a denial of service SSL/TLS layer outage via malformed ...

6.7AI score0.01553EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2013/03/07 12:00 a.m.•4 views

PT-2013-2922

Name of the Vulnerable Software and Affected Versions Cisco Small Business 200 Series Smart Switch versions 1.2.7.76 and earlier Cisco Small Business 300 Series Managed Switch versions 1.2.7.76 and earlier Cisco Small Business 500 Series Stackable Managed Switch versions 1.2.7.76 and earlier...

5CVSS0.01553EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/03/07 12:00 a.m.•5 views

CVE-2013-1154: Undefined Security Weakness

The Cisco Small Business 200 Series Smart Switch 1.2.7.76 and earlier, Small Business 300 Series Managed Switch 1.2.7.76 and earlier, and Small Business 500 Series Stackable Managed Switch 1.2.7.76 and earlier allow remote attackers to cause a denial of service SSL/TLS layer outage via malformed ...

5CVSS5.8AI score0.01553EPSS
SaveExploits0References2
CVE
CVE
•added 2013/02/01 11:00 a.m.•226 views

CVE-2012-3268

CVE-2012-3268 describes an SNMP information-disclosure vulnerability in HP/H3C/Huawei networking gear where protected h3c-user.mib/hh3c-user.mib objects can be queried via a read-only SNMP community, allowing remote authenticated users to enumerate usernames, passwords or password hashes in UserI...

3.5CVSS5.9AI score0.02263EPSS
SaveExploits0References9Affected Software664
Positive Technologies
Positive Technologies
•added 2013/02/01 12:00 a.m.•8 views

PT-2013-1583

Name of the Vulnerable Software and Affected Versions HP Access Controller versions affected versions not specified HP Fabric Module versions affected versions not specified HP Firewall versions affected versions not specified HP Router versions affected versions not specified HP Switch versions...

3.5CVSS0.02263EPSS
SaveExploits0References10
Rows per page
Query Builder