Lucene search
+L

6115 matches found

Microsoft CVE
Microsoft CVE
•added 2018/09/11 7:00 a.m.•48 views

Windows Hyper-V Denial of Service Vulnerability

A denial of service vulnerability exists when Microsoft Hyper-V Network Switch on a host server fails to properly validate input from a privileged user on a guest operating system. An attacker who successfully exploited the vulnerability could cause the host server to crash. To exploit the...

6.8CVSS3.3AI score0.07165EPSS
SaveExploits0
Microsoft CVE
Microsoft CVE
•added 2018/09/11 7:00 a.m.•32 views

Windows Hyper-V Denial of Service Vulnerability

A denial of service vulnerability exists when Microsoft Hyper-V Network Switch on a host server fails to properly validate input from a privileged user on a guest operating system. An attacker who successfully exploited the vulnerability could cause the host server to crash. To exploit the...

6.2CVSS3.3AI score0.02052EPSS
SaveExploits0
BDU FSTEC
BDU FSTEC
•added 2018/09/07 12:00 a.m.•12 views

The vulnerability of FL SWITCH microprogrammed software for controlled switches arises from operations that go beyond the buffer boundaries in memory. This allows attackers to access device operating system files and execute arbitrary code.

The vulnerability of the microprogrammed software for controlled switches from FL SWITCH from Phoenix Contact arises from an operation that goes beyond the buffer boundaries in memory. Exploiting this vulnerability can allow a malicious actor to gain unauthorized access to the device’s operating...

9.3CVSS6.1AI score0.02696EPSS
SaveExploits0References6Affected Software29
BDU FSTEC
BDU FSTEC
•added 2018/09/07 12:00 a.m.•16 views

The vulnerability of CGI applications of microprogramming software for controlled switches from FL SWITCH allows a hacker to access the contents of configuration files.

The vulnerability of CGI applications of microprogramming software for controlled switches from FL SWITCH Phoenix Contact is related to security mechanisms that are flawed. Exploiting this vulnerability can allow an attacker, operating remotely, to gain access to configuration files’ contents...

5.3CVSS5.5AI score0.01862EPSS
SaveExploits0References6Affected Software29
BDU FSTEC
BDU FSTEC
•added 2018/09/07 12:00 a.m.•14 views

The vulnerability of the config_transfer.cgi and software_update.cgi components of FL SWITCH software for controlling switches allows a hacker to execute arbitrary commands.

The vulnerability of the configtransfer.cgi and softwareupdate.cgi components of the FL SWITCH software for controlling switches from Phoenix Contact is related to the absence of a mechanism to neutralize special elements in the input commands of the operating system. Exploiting this vulnerabilit...

9.1CVSS5.8AI score0.04501EPSS
SaveExploits0References6Affected Software29
NVD
NVD
•added 2018/08/30 5:29 p.m.•29 views

CVE-2018-15478

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based o...

8.1CVSS8.2AI score0.00859EPSS
SaveExploits0References1
OSV
OSV
•added 2018/08/30 5:29 p.m.•17 views

CVE-2018-15477

myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...

9.8CVSS5.8AI score0.01592EPSS
SaveExploits0References1
NVD
NVD
•added 2018/08/30 5:29 p.m.•28 views

CVE-2018-15477

myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...

10CVSS9.6AI score0.01592EPSS
SaveExploits0References1
Prion
Prion
•added 2018/08/30 5:29 p.m.•27 views

Design/Logic Flaw

myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...

10CVSS9.4AI score0.01592EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2018/08/30 5:00 p.m.•53 views

CVE-2018-15477

The CVE set concerns myStrom WiFi Switch family with multiple issues in 2018. CVE-2018-15477 (and related CVEs 15476–15480) describe: a command-injection and OS-command execution risk in MyStrom devices where an unsanitized cloud parameter could be used to run commands on the device; affected: my...

10CVSS9.4AI score0.01592EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2018/08/30 5:00 p.m.•30 views

CVE-2018-15477

myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...

9.6AI score0.01592EPSS
SaveExploits0References1
CVE
CVE
•added 2018/08/30 5:00 p.m.•60 views

CVE-2018-15476

CVE-2018-15476 affects myStrom WiFi Switch family (V1 before 2.66, V2 before 3.80, EU before 3.80; related WiFi Bulb/LED Strip/Button versions). Root cause: the SSL/TLS server certificate used in device-to-cloud communication is not verified, enabling MITM attackers on the device network path to ...

9.3CVSS8AI score0.00756EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2018/08/30 5:00 p.m.•38 views

CVE-2018-15478

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based o...

8.2AI score0.00859EPSS
SaveExploits0References1
CVE
CVE
•added 2018/08/30 5:00 p.m.•57 views

CVE-2018-15480

CVE-2018-15480 affects multiple myStrom devices (WiFi Switch V1 <2.66, V2 <3.80, EU <3.80, Bulb <2.58, LED Strip <3.80, Button <2.73, Button Plus

8.8CVSS8.5AI score0.01024EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2018/08/30 5:00 p.m.•62 views

CVE-2018-15478

CVE-2018-15478 affects myStrom WiFi Switch and related devices (V1 < 2.66, V2 < 3.80, EU < 3.80, Bulb < 2.58, LED Strip < 3.80, Button < 2.73, Button Plus

8.1CVSS8.1AI score0.00859EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/30 12:00 a.m.•1 views

CVE-2018-15478: Improper Authentication

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based o...

8.1CVSS7.5AI score0.00859EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/30 12:00 a.m.•3 views

CVE-2018-15479: Improper Authentication

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to...

6.5CVSS6.8AI score0.00787EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/30 12:00 a.m.•1 views

CVE-2018-15476: Improper Certificate Validation

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication...

9.3CVSS7AI score0.00756EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/30 12:00 a.m.•2 views

CVE-2018-15477: Improper Neutralization of Special Elements used in an OS Command

myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...

10CVSS8.1AI score0.01592EPSS
SaveExploits0References2
OpenVAS
OpenVAS
•added 2018/08/30 12:00 a.m.•10 views

HPE OfficeConnect Switch Detection (SNMP)

SNMP based detection of HPE OfficeConnect switches. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.1AI score
SaveExploits0
Rows per page
Query Builder