Lucene search
+L

57 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2021-23740

Malware in sbrugna...

9.8CVSS8.2AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.9 views

EUVD-2021-23736

Malware in sbrugna...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2021-23734

Malware in sbrugna...

9.8CVSS9.4AI score0.08227EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2021-23738

Malware in sbrugna...

9.8CVSS9.2AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2021-23741

Malware in sbrugna...

10CVSS9.4AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2021-23735

Malware in sbrugna...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.7 views

EUVD-2021-23739

Malware in sbrugna...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2021-23737

Malware in sbrugna...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References6
RedhatCVE
RedhatCVE
added 2025/05/22 6:40 p.m.9 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS7.9AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.32 views

Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62180)

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability can be exploited to override the internal queue data structure, allowing for remote code execution...

9.8CVSS5AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.70 views

HMI3 Control Panel Trust Management Issue Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...

7.5CVSS2.1AI score0.01439EPSS
SaveExploits0Affected Software1
CNVD
CNVD
added 2021/08/04 12:0 a.m.55 views

Nexus Control Panel Elevation of Privilege Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An elevation of privilege vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to gain root access to the device, which would allow access to all device...

10CVSS5.1AI score0.01737EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.25 views

Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62179)

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...

9.8CVSS9.8AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.32 views

Nexus Control Panel Licensing Issue Vulnerability

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability stems from an improper method used to bind a local service to a port on the device interface. An attacker could use this...

7.8CVSS2.8AI score0.02062EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.82 views

Nexus Control Panel Out-of-Bounds Writing Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An out-of-bounds write vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to cause a stack buffer overflow...

9.8CVSS4AI score0.03396EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.54 views

Nexus Control Panel Buffer Overflow Vulnerability

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, is vulnerable to an integer underflow vulnerability in versions prior to Nexus Control Panel 7.2.5.7. An attacker could use this vulnerability to override the internal queue data structure, which could enable remote code...

9.8CVSS4.6AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.39 views

Nexus Control Panel Code Issue Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A code download without integrity check vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. The vulnerability stems from no file validation during the upload of an update. No details of the...

9.8CVSS9.5AI score0.08227EPSS
SaveExploits0References1
hivepro
hivepro
added 2021/08/03 1:5 p.m.40 views

Major Hospitals affected by PwnedPiper Vulnerabilities

THREAT LEVEL: White. For a detailed advisory, download the pdf file here. Multiple Zero-day vulnerabilities PwnedPiper have been found affecting the HMI-3 Control Panel of Swisslog Healthcare’s TransLogic Pneumatic Tube Systems PTS. PTS is a specialized system that uses compressor to transport...

7.5CVSS9.8AI score0.03396EPSS
SaveExploits0
CISA
CISA
added 2021/08/03 12:0 a.m.15 views

CISA Releases Security Advisory for Swisslog Healthcare

CISA has released an Industrial Control Systems ICS advisory detailing multiple vulnerabilities in Swisslog Healthcare Translogic Pneumatic Tube Systems PTS. An attacker could exploit some of these vulnerabilities to take control of an affected system. CISA encourages users and administrators to...

7.1AI score
SaveExploits0References1
ICS
ICS
added 2021/08/03 12:0 a.m.63 views

Swisslog Healthcare Translogic PTS

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Swisslog Healthcare Equipment: Translogic PTS Pneumatic Tube Systems Vulnerabilities: Use of Hard-coded Password, Execution with Unnecessary Privileges, Improper Authentication, Download of Code without...

10CVSS10AI score0.08227EPSS
SaveExploits0References5
Rows per page