10 matches found
CVE-2026-86749 snipe-it before 8.7.0 Data Loss via Failed Image Write
Snipe-IT versions put... call still caused the application to delete the previous image via deleteExistingImage and to reassign and persist the model's image reference to the new filename, destroying the existing image and leaving the database row pointing at a file that was never written. A mirr...
CVE-2026-86739 Snipe-IT before 8.7.0 Acceptance Finalization Without Stored Evidence
Snipe-IT 8.6.3 and earlier do not check the return value of Storage::put when writing the signature PNG and the generated acceptance PDF in Account\AcceptanceController::store. On filesystem drivers that return false instead of throwing on a write failure for example the local disk with restricti...
CVE-2026-86739
Snipe-IT versions 8.6.3 and earlier fail to check the return value of Storage::put() when writing the signature PNG and acceptance PDF in Account\AcceptanceController::store(). On filesystem drivers that return false instead of throwing on write failure (e.g., local disk with restrictive permissi...
Astra Linux – Vulnerability found in Linux 6.1, Linux 6.12
In the Linux kernel, the following vulnerabilities have been resolved: jbd2: avoided the bugon in jbd2journalgetcreateaccess when the file system is corrupted. The issue occurs when the file system is corrupted: ------------ cut here ------------ Kernel BUG at fs/jbd2/transaction.c:1289! Oops:...
BlobTierInadequateForContentLength during Machine Catalog Update
The following error is seen while updating a MCS Machine Catalog after resizing the size of the Master VM disk. Exception: StudioErrorId : ProvisioningTaskError ErrorCategory : NotSpecified TaskState : FailedToCreateImagePreparationVm TaskStateInformation : Terminated ErrorId :...
Error: "SR BACKEND FAILURE 181" in XenServer
After installation or upgrade to XenServer 6.0, user experiences issues with any storage related operations. The following error message appears: “SRBACKENDFAILURE181 Error In metadata Volume Operation For SR.” The following entries appears in the log /var/log/SMlog file: Error code:...
System fails back to a host copy instead of an array copy or storages go down after LUN reset in Windows Server 2012 R2
System fails back to a host copy instead of an array copy or storages go down after LUN reset in Windows Server 2012 R2 This article describes issues in which a storage system fails back to a host copy instead of an array copy or storage systems go down after a LUN reset in Windows Server 2012 R2...
XenServer - Failed to Attach Local Storage
Failed to attach local storage...
Cannot power on CachePoint, "Cannot open the disk 'UnideskLayers/..."
After host or storage failure, you may find that one or more CachePoints CP will not longer boot. The error message given by vCenter is: An error was received from the ESX host while powering on VM CP01. Cannot open the disk 'UnideskLayers/User/Desktop3/P14407081000000d8.B0.R1.V0-000001.vmdk' or...
All instances of storage metadata are corrupted
Challenge A task in Veeam Backup & Replication fails with the error: All instances of storage metadata are corrupted. Copy Cause It's important first to understand what the "storage metadata" is. The storage metadata is akin to an MFT master file table for the Veeam Backup & Replication backup...