1755 matches found
Automattic: Verification code issues for Two-Step Authentication
Hi there, I noticed two issues regarding the verification code that is sent to the phone as Two-Step Authentication for Wordpress accounts. I found out that verification code sent as SMS while enabling Two-Step Authentication can be reused infinitely for login. Issue1 The application does not...
Apple Moving to 2FA, Six-Digit Passcodes in iOS 9
With each new release of iOS, Apple has been improving the security of the mobile operating system, adding new features, inserting exploit mitigations, and taking away avenues for attack. In the forthcoming iOS 9.0 release, the company is continuing this movement with the addition of two-factor...
CVE-2015-1602
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
Information disclosure
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
CVE-2015-1601
CVE-2015-1601 affects Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1. The root cause is a man-in-the-middle vulnerability in network communications (Port 102/TCP) that can allow attackers to intercept or modify transmitted data, potentially exposing sensitive information or enab...
CVE-2015-1602
Siemens SIMATIC STEP 7 (TIA Portal) v12 and v13 prior to SP1 Upd1 are affected by CVE-2015-1602, which involves storing cleartext passwords in project files, enabling local attackers to reconstruct protection-level and web-server passwords from read files. The issue comprises two related weakness...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
KLA10534 Sensitive information obtain vulnerabilities in Siemens SIMATIC STEP
Improper password store and other uncnown vulnerability were found in SIMATIC STEP 7. By exploiting these vulnerabilities malicious users can obtain sensitive information. These vulnerabilities can be exploited remotely via an unknown vectors. Original advisories Siemens advisory Related products...
Various Siemens products have search path vulnerabilities
Siemens SIMATIC ProSave; SIMATIC CFC 8 SP4 upd9 8.1 upd1; SIMATIC STEP 7 5.5 SP1 Hf2 5.5 SP2 5.5 SP4 HF4 HF7 sp35.5; SIMOTION Scout 4.4 Starter 4.4 HF3 are all Siemens Siemens Germany company in Germany. A search path vulnerability exists in several Siemens products, allowing local users to gain...
Siemens SIMATIC STEP 7 (TIA Portal) Detection
Binary data scadaappsiemenstiastep7detect.nbin...
Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836)
Binary data scadasiemenstiamultiplevulnerabilitiesSSA-315836.nbin...
Siemens SIMATIC STEP 7 TIA Portal Password Hash Algorithm Security Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A security vulnerability exists in Siemens SIMATIC STEP 7 TIA that allows an attacker to exploit the vulnerability to access TIA project files, reconstruct passwords or WEB server passwords...
Siemens SIMATIC STEP 7 Sensitive Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A sensitive information disclosure vulnerability exists in Siemens SIMATIC STEP 7, which allows attackers to exploit the vulnerability to gain access to sensitive information due to the use of an insecure hash...
Siemens SIMATIC STEP 7 TIA Portal Man-in-the-Middle Attack Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A man-in-the-middle attack vulnerability exists in Siemens SIMATIC STEP 7 TCP port 102, which could be exploited by an attacker to intercept or modify communications...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
CVE-2015-1355
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
Authorization
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...