214 matches found
CVE-2022-28166
In Brocade SANnav, versions prior to SANN2.2.0.2 and prior to 2.1.1.8 expose TLS/SSL servers that support static key ciphers on ports 443 and 18082. Root cause: use of static key ciphers in the TLS/SSL server implementation. Impact: potential partial confidentiality disclosure; no data integrity ...
CVE-2022-28166
In Brocade SANnav version before SANN2.2.0.2 and Brocade SANNav before 2.1.1.8, the implementation of TLS/SSL Server Supports the Use of Static Key Ciphers ssl-static-key-ciphers on ports 443 & 18082...
Broadcom Brocade SANnav 加密问题漏洞
Broadcom Brocade SANnav is a SAN management platform from Broadcom Corporation. A security vulnerability exists in Brocade SANnav versions v2.2.0.2 and v2.1.1.8, which stems from the use of static key ciphers ssl-static-key-ciphers on ports 443 and 18082...
PT-2022-3072 · Brocade · Brocade Sannav
Name of the Vulnerable Software and Affected Versions: Brocade SANnav versions prior to 2.1.1.8 Brocade SANnav versions prior to SANN2.2.0.2 Description: The issue is related to the implementation of TLS/SSL Server in the Brocade SANnav software, which supports the use of static key ciphers on...
CVE-2022-23724
Use of static encryption key material allows forging an authentication token to other users within a tenant organization. MFA may be bypassed by redirecting an authentication flow to a target user. To exploit the vulnerability, must have compromised user credentials...
CVE-2021-34688
CVE-2021-34688 affects iDrive RemotePC on Windows prior to 7.6.48. A locally authenticated attacker can read an encrypted version of the system’s Personal Key from world-readable log files in %PROGRAMDATA%, because the encryption uses a hard-coded static key, making it reversible. The issue is a ...
CVE-2021-34688
iDrive RemotePC before 7.6.48 on Windows allows information disclosure. A locally authenticated attacker can read an encrypted version of the system's Personal Key in world-readable %PROGRAMDATA% log files. The encryption is done using a hard-coded static key and is therefore reversible by an...
CVE-2020-11719
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. It relies on broken encryption with a weak and guessable static encryption key...
CVE-2020-25229
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
CVE-2020-25231
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program fil...
CVE-2020-25229
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
Command injection
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
Design/Logic Flaw
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program fil...
CVE-2020-25231
CVE-2020-25231 affects Siemens LOGO! 8 BM (incl. SIPLUS variants) and LOGO! Soft Comfort with all versions before 8.3. The root cause is a static cryptographic key used to encrypt program data, enabling an attacker to extract confidential information from protected program files. Impact is inform...
CVE-2020-25229
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
CVE-2020-25231
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program fil...
Design/Logic Flaw
RVToolsPasswordEncryption.exe in RVTools 4.0.6 allows users to encrypt passwords to be used in the configuration files. This encryption used a static IV and key, and thus using the Decrypt method from VISKD.cs from the RVTools.exe executable allows for decrypting the encrypted passwords. The...
CVE-2020-13260
A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as th...
CVE-2020-13260
A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as th...
Cross site scripting