Lucene search
+L

22694 matches found

Vulnrichment
Vulnrichment
•added 2024/03/28 12:00 a.m.•16 views

CVE-2024-3011 Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. T...

9CVSS7AI score0.01849EPSS
SaveExploits1References4
Cvelist
Cvelist
•added 2024/03/28 12:00 a.m.•56 views

CVE-2024-3011 Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. T...

9CVSS9AI score0.01849EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30585: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

6.5CVSS6AI score0.00518EPSS
SaveExploits1References2
Zero Day Initiative
Zero Day Initiative
•added 2024/03/28 12:00 a.m.•44 views

Linux Kernel nft_exthdr_tcp_eval Stack-based Buffer Overflow Information Disclosure Vulnerability

This vulnerability allows local attackers to disclose sensitive information on affected installations of the Linux Kernel. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the...

7.3CVSS6.5AI score0.00662EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-28014: Stack-based Buffer Overflow

Stack-based Buffer Overflow vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX-MS, WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800H...

9.8CVSS6.2AI score0.00689EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-3011: Stack-based Buffer Overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. T...

9CVSS6.2AI score0.01849EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•8 views

CVE-2024-30588: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function...

4.3CVSS6AI score0.00446EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-30591: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function...

8.8CVSS6AI score0.00685EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30586: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the security5g parameter of the formWifiBasicSet function...

6.5CVSS6AI score0.00516EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30595: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function...

9.8CVSS6AI score0.00807EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•10 views

CVE-2024-30590: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•3 views

CVE-2024-3012: Stack-based Buffer Overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated...

9CVSS6.3AI score0.01849EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•8 views

CVE-2024-30589: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function...

9.8CVSS6AI score0.00729EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30592: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the page parameter of the fromAddressNat function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•4 views

CVE-2024-30600: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

8CVSS6AI score0.00696EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•5 views

CVE-2024-30607: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30594: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-30612: Stack-based Buffer Overflow

Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function...

8.1CVSS6AI score0.00667EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2024/03/27 11:31 p.m.•41 views

CVE-2024-3010 Tenda FH1205 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775 and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been...

9CVSS8.9AI score0.01773EPSS
SaveExploits1References4
CVE
CVE
•added 2024/03/27 11:31 p.m.•90 views

CVE-2024-3010

The CVE-2024-3010 entry affects Tenda FH1205 version 2.0.0.7(775). The vulnerability is in the function formSetCfm of the file /goform/setcfm, where manipulation of the funcpara1 argument leads to a stack-based buffer overflow. The issue can be exploited remotely and the exploit has been publicly...

9CVSS8.8AI score0.01773EPSS
SaveExploits1References4Affected Software1
Rows per page
Query Builder