20394 matches found
CVE-2024-2983 Tenda FH1202 SetClientState formSetClientState stack-based overflow
A vulnerability was found in Tenda FH1202 1.2.0.14408 and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be...
CVE-2024-2983 Tenda FH1202 SetClientState formSetClientState stack-based overflow
A vulnerability was found in Tenda FH1202 1.2.0.14408 and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be...
CVE-2024-2981
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14408. Affected is the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotel...
CVE-2024-2981 Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14408. Affected is the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotel...
CVE-2024-2981 Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14408. Affected is the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotel...
CVE-2024-2981
CVE-2024-2981 affects Tenda FH1202 1.2.0.14(408). The vulnerable component is the function form_fast_setting_wifi_set in /goform/fast_setting_wifi_set, where manipulation of the ssid argument leads to a stack-based buffer overflow. This enables remote exploitation, and public exploits have been d...
CVE-2024-2980 Tenda FH1202 execCommand formexeCommand stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14408. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-2980 Tenda FH1202 execCommand formexeCommand stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14408. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-2977
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-2979
A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-2976
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched...
CVE-2024-2979
CVE-2024-2979 affects Tenda F1203 v2.0.1.6: the setSchedWifi function in /goform/openSchedWifi is vulnerable to a stack-based buffer overflow triggered by manipulating schedStartTime/schedEndTime. This enables remote attack with potential arbitrary code execution or crash/DoS; exploitation has be...
CVE-2024-2978 Tenda F1203 setcfm formSetCfm stack-based overflow
A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been...
CVE-2024-2977 Tenda F1203 QuickIndex formQuickIndex stack-based overflow
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-2977 Tenda F1203 QuickIndex formQuickIndex stack-based overflow
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-2976 Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched...
CVE-2024-2977: Stack-based Buffer Overflow
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-2983: Stack-based Buffer Overflow
A vulnerability was found in Tenda FH1202 1.2.0.14408 and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be...
CVE-2024-2981: Stack-based Buffer Overflow
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14408. Affected is the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotel...
Autodesk DWG TrueView DWG File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Autodesk DWG TrueView. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing ...