13869 matches found
CVE-2025-7087: Stack-based Buffer Overflow
A vulnerability classified as critical was found in Belkin F9K1122 1.00.33. Affected by this vulnerability is the function formL2TPSetup of the file /goform/formL2TPSetup of the component webs. The manipulation of the argument L2TPUserName leads to stack-based buffer overflow. The attack can be...
CVE-2025-7094: Stack-based Buffer Overflow
A vulnerability was found in Belkin F9K1122 1.00.33. It has been rated as critical. Affected by this issue is the function formBSSetSitesurvey of the file /goform/formBSSetSitesurvey of the component webs. The manipulation of the argument submit-url-ok leads to stack-based buffer overflow. The...
CVE-2025-7085: Stack-based Buffer Overflow
A vulnerability was found in Belkin F9K1122 1.00.33. It has been rated as critical. This issue affects the function formiNICWpsStart of the file /goform/formiNICWpsStart of the component webs. The manipulation of the argument pinCode leads to stack-based buffer overflow. The attack may be initiat...
CVE-2025-7086: Stack-based Buffer Overflow
A vulnerability classified as critical has been found in Belkin F9K1122 1.00.33. Affected is the function formPPTPSetup of the file /goform/formPPTPSetup of the component webs. The manipulation of the argument pptpUserName leads to stack-based buffer overflow. It is possible to launch the attack...
PT-2025-29192 · Tenda · Tenda O3V2
Name of the Vulnerable Software and Affected Versions: Tenda O3V2 version 1.0.0.123880 Description: A critical vulnerability exists in the Tenda O3V2 device. The vulnerability is located within the formWifiMacFilterSet function of the httpd component, specifically in the file...
PT-2025-29191 · Tenda · Tenda O3V2
Name of the Vulnerable Software and Affected Versions: Tenda O3V2 version 1.0.0.123880 Description: A critical vulnerability exists in Tenda O3V2. The setAutoReboot function within the /goform/setNetworkService file of the httpd component is affected. Manipulation of the week argument causes a...
CVE-2025-6072
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6073: Stack-based Buffer Overflow
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer...
PT-2025-27816 · Abb · Abb Rmc-100 Lite +1
Name of the Vulnerable Software and Affected Versions: ABB RMC-100 versions 2105457-043 through 2105457-045 ABB RMC-100 LITE versions 2106229-015 through 2106229-016 Description: The issue is a Stack-based Buffer Overflow vulnerability. When the REST interface is enabled and an attacker gains...
CVE-2025-6072: Stack-based Buffer Overflow
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6886
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be...
PT-2025-28805 · D Link · D-Link Dir-825
Name of the Vulnerable Software and Affected Versions: D-Link DIR-825 version 2.10 Description: A critical vulnerability exists in the D-Link DIR-825 router. This issue affects the sub 410DDC function within the switch language.cgi file of the httpd component. Manipulation of the Language paramet...
CVE-2025-24328: Stack-based Buffer Overflow
Sending a crafted SOAP "set" operation message within the Mobile Network Operator MNO internal Radio Access Network RAN management network can cause Nokia Single RAN baseband OAM service component restart with software versions earlier than release 24R1-SR 1.0 MP. This issue has been corrected to...
CVE-2025-6887: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2025-6886: Stack-based Buffer Overflow
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be...
CVE-2024-53621: Stack-based Buffer Overflow
A buffer overflow in the formSetCfm function of Tenda AC1206 1200M 11ac USAC1206V1.0RTLV15.03.06.23multiTD01 allows attackers to cause a Denial of Service DoS via a crafted POST request...
CVE-2025-6857: Stack-based Buffer Overflow
A vulnerability has been found in HDF5 1.14.6 and classified as problematic. Affected by this vulnerability is the function H5Gnodecmp3 of the file src/H5Gnode.c. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack on the local host. The exploit has been...
PT-2025-27358
Name of the Vulnerable Software and Affected Versions: HDF5 version 1.14.6 Description: A stack-based buffer overflow issue has been found, affecting the function H5G node cmp3 in the file src/H5Gnode.c. This issue can be exploited locally. Recommendations: For HDF5 version 1.14.6, consider...
Security Bulletin: Due to use of Corosync, IBM MQ is vulnerable to a stack-based buffer overflow
Summary Corosync is used by IBM MQ as part of the RDQM component CVE-2025-30472 Vulnerability Details CVEID:CVE-2025-30472 DESCRIPTION: Corosync through 3.1.9, if encryption is disabled or the attacker knows the encryption key, has a stack-based buffer overflow in orftokenendianconvert in...
CVE-2025-5829
Autel MaxiCharger AC Wallbox Commercial autocharge Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers...