Lucene search
+L

11571 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/29 12:00 a.m.•2 views

CVE-2024-30623: Stack-based Buffer Overflow

Tenda FH1205 v2.0.0.7775 has a stack overflow vulnerability in the page parameter from fromDhcpListClient function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/29 12:00 a.m.•0 views

CVE-2024-30626: Stack-based Buffer Overflow

Tenda FH1205 v2.0.0.7775 has a stack overflow vulnerability in the schedEndTime parameter from setSchedWifi function...

8CVSS6AI score0.00696EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/29 12:00 a.m.•0 views

CVE-2024-30639: Stack-based Buffer Overflow

Tenda F1202 v1.2.0.20408 has a stack overflow vulnerability in the page parameter of fromAddressNat function...

6.5CVSS6AI score0.00523EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/29 12:00 a.m.•0 views

CVE-2024-30632: Stack-based Buffer Overflow

Tenda FH1205 v2.0.0.7775 has a stack overflow vulnerability in the security5g parameter from formWifiBasicSet function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/29 12:00 a.m.•0 views

CVE-2024-30636: Stack-based Buffer Overflow

Tenda F1202 v1.2.0.20408 has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function...

6.5CVSS6AI score0.00417EPSS
SaveExploits1References2
NVD
NVD
•added 2024/03/28 1:15 a.m.•25 views

CVE-2024-28014

Stack-based Buffer Overflow vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX-MS, WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800H...

9.8CVSS7AI score0.00689EPSS
SaveExploits0References2
CVE
CVE
•added 2024/03/28 12:56 a.m.•98 views

CVE-2024-28014

NEC Corporation Aterm series wireless routers are affected by a Stack-based Buffer Overflow vulnerability (CVE-2024-28014) across all versions of numerous models, including WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF3...

7.2AI score0.00689EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2024/03/28 12:00 a.m.•49 views

CVE-2024-3011

CVE-2024-3011 affects Tenda FH1205 (version 2.0.0.7(775)). The vulnerability is in the function formQuickIndex of the file /goform/QuickIndex , where manipulating the PPPOEPassword parameter causes a stack-based buffer overflow . Exploitation can be performed remotely, and multiple sources note t...

9CVSS8.9AI score0.01849EPSS
SaveExploits1References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•0 views

CVE-2024-30591: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function...

8.8CVSS6AI score0.00685EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30612: Stack-based Buffer Overflow

Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function...

8.1CVSS6AI score0.00667EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•0 views

CVE-2024-30590: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30607: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30589: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function...

9.8CVSS6AI score0.00729EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30588: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function...

4.3CVSS6AI score0.00446EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•2 views

CVE-2024-30585: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

6.5CVSS6AI score0.00518EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•0 views

CVE-2024-30600: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

8CVSS6AI score0.00696EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•0 views

CVE-2024-30592: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the page parameter of the fromAddressNat function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30586: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the security5g parameter of the formWifiBasicSet function...

6.5CVSS6AI score0.00516EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•0 views

CVE-2024-30594: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•1 views

CVE-2024-30595: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function...

9.8CVSS6AI score0.00807EPSS
SaveExploits1References2
Rows per page
Query Builder