11578 matches found
CVE-2024-3907: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
CVE-2024-3905: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely...
CVE-2023-5403: Stack-based Buffer Overflow
Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2024-32318: Stack-based Buffer Overflow
Tenda AC500 V2.0.1.91307 firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function...
CVE-2024-32311: Stack-based Buffer Overflow
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function...
CVE-2024-32288: Stack-based Buffer Overflow
Tenda W30E v1.0 V1.0.1.25633 firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function...
CVE-2024-32303: Stack-based Buffer Overflow
Tenda AC15 v15.03.20multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function...
CVE-2024-32290: Stack-based Buffer Overflow
Tenda W30E v1.0 v1.0.1.25633 firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function...
CVE-2024-3909: Stack-based Buffer Overflow
A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...
CVE-2023-5395: Stack-based Buffer Overflow
Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5401: Stack-based Buffer Overflow
Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2024-32299: Stack-based Buffer Overflow
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function...
CVE-2024-32305: Stack-based Buffer Overflow
Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function...
CVE-2024-3882
A vulnerability was found in Tenda W30E 1.0.1.25633. It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...
CVE-2024-3881
Summary: CVE-2024-3881 affects Tenda W30E 1.0.1.25(633). A stack-based buffer overflow exists in the frmL7PlotForm function of /goform/frmL7ProtForm caused by improper handling of the page parameter. This can be exploited remotely and an exploit has been disclosed publicly. Impact: Confidentialit...
CVE-2024-3879
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25633. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has...
CVE-2024-3878
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20408. Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be...
CVE-2024-3875
A vulnerability was found in Tenda F1202 1.2.0.20408. It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
CVE-2024-3876
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20408. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been...
CVE-2024-3874
A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated...