Lucene search
+L

11587 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•1 views

CVE-2024-4251: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buff...

9CVSS6.3AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•1 views

CVE-2024-4291: Stack-based Buffer Overflow

A vulnerability was found in Tenda A301 15.13.08.12multiTDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated...

9CVSS6.2AI score0.01453EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•0 views

CVE-2024-4248: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. This issue affects the function formQosManageuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability...

9CVSS6.3AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•0 views

CVE-2024-4245: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.144656. Affected by this issue is the function formQosManageDoubleuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this...

9CVSS6.3AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•1 views

CVE-2024-4250: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotel...

9CVSS6.3AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•2 views

CVE-2024-4249: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS6.2AI score0.01349EPSS
SaveExploits0References3
CVE
CVE
•added 2024/04/26 8:31 p.m.•85 views

CVE-2024-4239

The CVE-2024-4239 vulnerability affects the Tenda AX1806 (version 1.0.0.1) and centers on the function formSetRebootTimer in /goform/SetRebootTimer. The rebootTime argument can cause a stack-based buffer overflow, enabling a remote attacker to potentially execute code or crash the device. Exploit...

9CVSS6.8AI score0.01451EPSS
SaveExploits0References4Affected Software1
CVE
CVE
•added 2024/04/26 7:00 p.m.•79 views

CVE-2024-4237

CVE-2024-4237 — Tenda AX1806 (1.0.0.1) Affected component: R7WebsSecurityHandler in /goform/execCommand. Technical detail: manipulating the password argument leads to a stack-based buffer overflow, with a remote-exploit potential. Public exploits have been disclosed. Public references consistentl...

9CVSS7AI score0.01451EPSS
SaveExploits0References4Affected Software1
CNVD
CNVD
•added 2024/04/26 12:00 a.m.•27 views

Unspecified Vulnerability in Tenda 4G300

Tenda 4G300 is a wireless router from Tenda China. A security vulnerability exists in the Tenda 4G300 version 1.01.42, which stems from an incorrect manipulation of the parameter GO/page that can lead to a stack-based buffer overflow. No details of the vulnerability are provided at this time...

9CVSS7AI score0.01755EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2024-4241: Stack-based Buffer Overflow

A vulnerability was found in Tenda W9 1.0.0.74456. It has been declared as critical. This vulnerability affects the function formQosManageDoubleauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this...

9CVSS6.3AI score0.01347EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2024-4240: Stack-based Buffer Overflow

A vulnerability was found in Tenda W9 1.0.0.74456. It has been classified as critical. This affects the function formQosManageDoubleuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of...

9CVSS6.3AI score0.01451EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2023-6095: Stack-based Buffer Overflow

Vladimir Kononovich, a Security Researcher has found a flaw that allows for a remote code execution on the DVR. An attacker could inject malicious HTTP headers into request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the...

8.9CVSS6.9AI score0.00661EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•1 views

CVE-2024-4243: Stack-based Buffer Overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.74456. Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has be...

9CVSS6.2AI score0.01347EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2024-4242: Stack-based Buffer Overflow

A vulnerability was found in Tenda W9 1.0.0.74456. It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

9CVSS6.3AI score0.01347EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2024-4238: Stack-based Buffer Overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched...

9CVSS6.2AI score0.01451EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2024-4239: Stack-based Buffer Overflow

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The...

9CVSS6.3AI score0.01451EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•0 views

CVE-2023-6116: Stack-based Buffer Overflow

Team ENVY, a Security Research TEAM has found a flaw that allows for a remote code execution on the camera. An attacker could inject malicious into http request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report...

8.9CVSS6.9AI score0.00661EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•1 views

CVE-2024-4244: Stack-based Buffer Overflow

A vulnerability classified as critical was found in Tenda W9 1.0.0.74456. Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffe...

9CVSS6.2AI score0.01347EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•1 views

CVE-2024-4237: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS6.2AI score0.01451EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/26 12:00 a.m.•2 views

CVE-2024-4236: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack ma...

9CVSS6.2AI score0.14879EPSS
SaveExploits0References3
Rows per page
Query Builder