13311 matches found
CVE-2024-4168 Tenda 4G300 sub_4260F0 stack-based overflow
A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability...
CVE-2024-4167
CVE-2024-4167 affects Tenda 4G300 with firmware 1.01.42. The vulnerability targets the function sub_422AA4 and arises from manipulation of year/month/day/hour/minute/second arguments, causing a stack-based buffer overflow that can be exploited remotely. References indicate VDB-261986 as the vulne...
CVE-2024-4167 Tenda 4G300 sub_422AA4 stack-based overflow
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier...
CVE-2024-4167 Tenda 4G300 sub_422AA4 stack-based overflow
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier...
CVE-2024-4166 Tenda 4G300 sub_41E858 stack-based overflow
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to...
CVE-2024-4166 Tenda 4G300 sub_41E858 stack-based overflow
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to...
CVE-2024-4165 Tenda G3 modifyDhcpRule stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.179502. Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. T...
CVE-2024-4164 Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.179502. This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The...
CVE-2024-4164 Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.179502. This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The...
PT-2024-29489 · Tenda · Tenda 4G300
Name of the Vulnerable Software and Affected Versions: Tenda 4G300 version 1.01.42 Description: A critical issue has been found, affecting the function sub 41E858. The manipulation of the argument GO/page leads to a stack-based buffer overflow. This issue can be exploited remotely. The vendor was...
CVE-2024-4126
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...
CVE-2024-4127
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifi...
CVE-2024-4127 Tenda W15E guestWifiRuleRefresh stack-based overflow
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifi...
CVE-2024-4126
CVE-2024-4126 affects Tenda W15E devices running 15.11.0.14. The vulnerability is a stack-based buffer overflow in the formSetSysTimeCfg component’s SetSysTimeCfg, triggered by manipulating the manualTime argument. It appears exploitable remotely and has been publicly disclosed. The CVSS metrics ...
CVE-2024-4124
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack...
CVE-2024-4125 Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated...
CVE-2024-4125 Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated...
CVE-2024-4125
CVE-2024-4125 – Tenda W15E Affected: Tenda W15E router, version 15.11.0.14. Vulnerable component: the function formSetStaticRoute in file /goform/setStaticRoute. Root cause: manipulation of the staticRouteIndex argument leads to a stack-based buffer overflow. Impact: enables remote execution with...
CVE-2024-4123 Tenda W15E SetPortMapping formSetPortMapping stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument...
CVE-2024-4123
CVE-2024-4123 affects Tenda W15E firmware 15.11.0.14. The vulnerability is a stack-based overflow in the function formSetPortMapping of /goform/SetPortMapping, triggered by manipulating arguments portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal. It can ...