8498 matches found
CVE-2024-4111
The vulnerability CVE-2024-4111 affects Tenda TX9 (firmware 22.03.02.10). Specifically, the sub_42BD7C function in /goform/SetLEDCfg mishandles the time argument, causing a stack-based buffer overflow. This can potentially be exploited remotely and is reported as high severity with public exploit...
CVE-2024-4065
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4064
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-4065
The CVE-2024-4065 entry concerns the Tenda AC8 firmware (16.03.34.09) with a stack-based buffer overflow in the formSetRebootTimer function exposed via /goform/SetRebootTimer. The rebootTime parameter manipulation can be exploited remotely to run arbitrary code. Multiple sources confirm remote at...
CVE-2024-4064 Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-4064
CVE-2024-4064 affects Tenda AC8 16.03.34.09. The R7WebsSecurityHandler function in /goform/execCommand mishandles the password parameter, causing a stack-based buffer overflow. This enables remote exploitation; the exploit has been disclosed publicly. Multiple sources (NVD, Red Hat, CNVD, CNNVD, ...
CVE-2024-33212
Tenda FH1206 V1.2.0.88155EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm...
CVE-2024-33215
Tenda FH1206 V1.2.0.88155EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat...
CVE-2024-33212
Summary (CVE-2024-33212) The issue affects the Tenda FH1206 router (version 1.2.0.8(8155)_EN). A stack-based buffer overflow exists in the IP management endpoint ip/goform/setcfm when processing the funcpara1 parameter. The vulnerability is characterized as a stack overflow that could lead to arb...
CVE-2024-33212
Tenda FH1206 V1.2.0.88155EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm...
CVE-2024-33214
Tenda FH1206 V1.2.0.88155EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic...
CVE-2023-4232 Ofono: sms decoder stack-based buffer overflow remote code execution vulnerability within the decode_status_report() function
A flaw was found in ofono, an Open Source Telephony on Linux. A stack overflow bug is triggered within the decodestatusreport function during the SMS decoding. It is assumed that the attack scenario is accessible from a compromised modem, a malicious base station, or just SMS. There is a bound...
CVE-2024-3910
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.91307. Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched...
CVE-2024-3909
A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...
CVE-2024-3910
CVE-2024-3910 affects Tenda AC500 2.0.1.9(1307). The flaw is in the fromDhcpListClient function (file /goform/DhcpListClient) where manipulating the page parameter causes a stack-based buffer overflow. Impact is described as remote code execution with high severity/impact across confidentiality, ...
CVE-2024-3905
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely...
CVE-2024-3906
CVE-2024-3906 affects Tenda AC500 (version 2.0.1.9(1307)) via the formQuickIndex function in /goform/QuickIndex. The root cause is a stack-based buffer overflow triggered when the PPPOEPassword parameter is manipulated, enabling remote exploitation. Publicized exploit details indicate in-the-wild...
CVE-2024-3905
CVE-2024-3905 affects Tenda AC500 2.0.1.9(1307). The flaw is in the R7WebsSecurityHandler function of the /goform/execCommand file, where manipulating the password argument causes a stack-based buffer overflow. It is exploitable remotely, and public exploits have been disclosed. Mitigations docum...
CVE-2024-3882
A vulnerability was found in Tenda W30E 1.0.1.25633. It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...
CVE-2024-3881
Summary: CVE-2024-3881 affects Tenda W30E 1.0.1.25(633). A stack-based buffer overflow exists in the frmL7PlotForm function of /goform/frmL7ProtForm caused by improper handling of the page parameter. This can be exploited remotely and an exploit has been disclosed publicly. Impact: Confidentialit...