Lucene search
+L

16193 matches found

Vulnrichment
Vulnrichment
•added 2024/03/17 3:31 a.m.•20 views

CVE-2024-2547 Tenda AC18 R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the...

9CVSS7AI score0.01186EPSS
SaveExploits0References3
CVE
CVE
•added 2024/03/17 3:31 a.m.•126 views

CVE-2024-2547

CVE-2024-2547 affects Tenda AC18, version 15.03.05.05, specifically the R7WebsSecurityHandler. The issue is a stack‑based buffer overflow triggered by manipulating the password argument, and the attack is network‑based with the potential for remote exploitation. Publicly disclosed exploit informa...

9CVSS8.9AI score0.01186EPSS
SaveExploits0References3Affected Software1
NVD
NVD
•added 2024/03/17 2:15 a.m.•38 views

CVE-2024-2546

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapskcrypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has bee...

9CVSS8.9AI score0.0099EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/17 12:00 a.m.•7 views

CVE-2024-2547: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the...

9CVSS6.2AI score0.01186EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/17 12:00 a.m.•7 views

CVE-2024-2546: Stack-based Buffer Overflow

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapskcrypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has bee...

9CVSS6.2AI score0.0099EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/17 12:00 a.m.•13 views

CVE-2024-2558: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

9CVSS6.3AI score0.01278EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2024/03/17 12:00 a.m.•4 views

PT-2024-14444

Name of the Vulnerable Software and Affected Versions gross versions 0.9.3 through 1.x before 1.0.4 Description A stack-based buffer overflow vulnerability allows remote attackers to trigger a denial of service grossd daemon crash or potentially execute arbitrary code in grossd via crafted SMTP...

7.5CVSS0.01055EPSS
SaveExploits0References20
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/17 12:00 a.m.•7 views

CVE-2024-23138: Stack-based Buffer Overflow

A maliciously crafted DWG file when parsed through Autodesk DWG TrueView can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process...

7.8CVSS6.4AI score0.0047EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2024/03/16 12:00 a.m.•6 views

PT-2024-20957

Name of the Vulnerable Software and Affected Versions Tenda AC18 version 15.13.07.09 Description A critical issue has been found, affecting the fromSetWirelessRepeat function. The manipulation of the wpapsk crypto5g argument leads to a stack-based buffer overflow. This issue can be exploited...

9.8CVSS0.0099EPSS
SaveExploits0References9
Positive Technologies
Positive Technologies
•added 2024/03/16 12:00 a.m.•8 views

PT-2024-2393

Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.20 multi Description A critical issue affects the saveParentControlInfo function of the file "/goform/saveParentControlInfo". The manipulation of the urls argument leads to a stack-based buffer overflow. This can be...

9.8CVSS0.01298EPSS
SaveExploits1References8
IBM Security Bulletins
IBM Security Bulletins
•added 2024/03/15 1:49 p.m.•71 views

Security Bulletin: IBM App Connect Enterprise is vulnerable to a denial of service due to json-path [CVE-2023-51074]

Summary The Transformation Advisor Tool in IBM App Connect Enterprise is vulnerable to a denial of service due to json-path. This bulletin identifies the steps to take to address the vulnerability. Vulnerability Details CVEID:CVE-2023-51074 DESCRIPTION: json-path is vulnerable to a denial of...

5.3CVSS5.8AI score0.00676EPSS
SaveExploits1Affected Software1
NVD
NVD
•added 2024/03/15 10:15 a.m.•41 views

CVE-2024-2490

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched...

9CVSS8.9AI score0.01648EPSS
SaveExploits1References3
CVE
CVE
•added 2024/03/15 9:31 a.m.•91 views

CVE-2024-2490

CVE-2024-2490 affects Tenda AC18 with firmware 15.03.05.05. The vulnerability is a stack-based buffer overflow in the setSchedWifi function (/goform/openSchedWifi) caused by improper handling of schedStartTime/schedEndTime, exploitable remotely and publicly disclosed. There is no confirmed patch ...

9CVSS8.9AI score0.01648EPSS
SaveExploits1References3Affected Software1
NVD
NVD
•added 2024/03/15 9:15 a.m.•36 views

CVE-2024-2487

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated...

9CVSS8.8AI score0.01648EPSS
SaveExploits1References3
Vulnrichment
Vulnrichment
•added 2024/03/15 9:00 a.m.•24 views

CVE-2024-2489 Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has...

9CVSS7AI score0.01648EPSS
SaveExploits1References3
CVE
CVE
•added 2024/03/15 9:00 a.m.•94 views

CVE-2024-2488

CVE-2024-2488 affects Tenda AC18 (firmware 15.03.05.05). The issue is a stack-based buffer overflow in the startIP parameter of the function formSetPPTPServer in /goform/SetPptpServerCfg . It can be exploited remotely and has been publicly disclosed, with potential impact on confidentiality, inte...

9CVSS8.9AI score0.01534EPSS
SaveExploits1References3Affected Software1
CVE
CVE
•added 2024/03/15 8:31 a.m.•112 views

CVE-2024-2487

CVE-2024-2487 affects the Tenda AC18 router (version 15.03.05.05). The vulnerability is in the function formSetDeviceName of the file /goform/SetOnlineDevName, where manipulating the devName/mac arguments causes a stack-based buffer overflow. Impact details per sources indicate the issue can be e...

9CVSS8.8AI score0.01648EPSS
SaveExploits1References3Affected Software1
NVD
NVD
•added 2024/03/15 8:15 a.m.•39 views

CVE-2024-2486

A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. Th...

9CVSS8.9AI score0.01563EPSS
SaveExploits1References3
CVE
CVE
•added 2024/03/15 8:00 a.m.•88 views

CVE-2024-2486

CVE-2024-2486 affects Tenda AC18 firmware version 15.03.05.05. The issue is a stack-based buffer overflow in the formQuickIndex function of /goform/QuickIndex caused by manipulating the PPPOEPassword parameter. The vulnerability can be exploited remotely, and public exploits have been disclosed (...

9CVSS8.9AI score0.01563EPSS
SaveExploits1References3Affected Software1
NVD
NVD
•added 2024/03/15 7:15 a.m.•41 views

CVE-2024-2485

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speeddir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit...

9CVSS8.8AI score0.01684EPSS
SaveExploits1References4
Rows per page
Query Builder