Lucene search
+L

16173 matches found

CVE
CVE
•added 2024/03/28 12:56 a.m.•107 views

CVE-2024-28014

The NEC Corporation Aterm series of wireless routers is vulnerable to a stack-based buffer overflow (CWE-120) across all versions of numerous models, including WG1800HP4 , WG1200HS3 , WR8165N , WR7870S , and WM3400RN , among others. This vulnerability allows an unauthenticated attacker to execute...

9.8CVSS7.2AI score0.00689EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2024/03/28 12:00 a.m.•59 views

CVE-2024-3011

CVE-2024-3011 affects Tenda FH1205 (version 2.0.0.7(775)). The vulnerability is in the function formQuickIndex of the file /goform/QuickIndex , where manipulating the PPPOEPassword parameter causes a stack-based buffer overflow . Exploitation can be performed remotely, and multiple sources note t...

9CVSS8.9AI score0.01849EPSS
SaveExploits1References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•3 views

CVE-2024-3012: Stack-based Buffer Overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated...

9CVSS6.3AI score0.01849EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-3011: Stack-based Buffer Overflow

A vulnerability was found in Tenda FH1205 2.0.0.7775. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. T...

9CVSS6.2AI score0.01849EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30588: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function...

4.3CVSS6AI score0.00446EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•8 views

CVE-2024-30589: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function...

9.8CVSS6AI score0.00729EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•5 views

CVE-2024-30600: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

8CVSS6AI score0.00696EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•8 views

CVE-2024-30591: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function...

8.8CVSS6AI score0.00685EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•10 views

CVE-2024-30592: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the page parameter of the fromAddressNat function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•10 views

CVE-2024-30586: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the security5g parameter of the formWifiBasicSet function...

6.5CVSS6AI score0.00516EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30595: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function...

9.8CVSS6AI score0.00807EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•10 views

CVE-2024-30590: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•5 views

CVE-2024-30607: Stack-based Buffer Overflow

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

8CVSS6AI score0.00689EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•7 views

CVE-2024-28014: Stack-based Buffer Overflow

Stack-based Buffer Overflow vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX-MS, WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800H...

9.8CVSS6.2AI score0.00689EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•9 views

CVE-2024-30585: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function...

6.5CVSS6AI score0.00518EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•8 views

CVE-2024-30612: Stack-based Buffer Overflow

Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function...

8.1CVSS6AI score0.00667EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/28 12:00 a.m.•11 views

CVE-2024-30594: Stack-based Buffer Overflow

Tenda FH1202 v1.2.0.14408 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function...

6.5CVSS6AI score0.00528EPSS
SaveExploits1References2
CVE
CVE
•added 2024/03/27 11:31 p.m.•91 views

CVE-2024-3010

The CVE-2024-3010 entry affects Tenda FH1205 version 2.0.0.7(775). The vulnerability is in the function formSetCfm of the file /goform/setcfm, where manipulation of the funcpara1 argument leads to a stack-based buffer overflow. The issue can be exploited remotely and the exploit has been publicly...

9CVSS8.8AI score0.01773EPSS
SaveExploits1References4Affected Software1
NVD
NVD
•added 2024/03/27 11:15 p.m.•41 views

CVE-2024-3006

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7775. This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The...

9CVSS8.9AI score0.01683EPSS
SaveExploits1References4
NVD
NVD
•added 2024/03/27 8:15 p.m.•38 views

CVE-2024-2994

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched...

9CVSS8.9AI score0.01481EPSS
SaveExploits1References4
Rows per page
Query Builder