16170 matches found
CVE-2023-50007: Stack-based Buffer Overflow
FFmpeg v.n6.1-3-g466799d4f5 allows an attacker to trigger use of a parameter of negative size in the avsamplessetsilence function in thelibavutil/samplefmt.c:260:9 component...
CVE-2023-4232 Ofono: sms decoder stack-based buffer overflow remote code execution vulnerability within the decode_status_report() function
A flaw was found in ofono, an Open Source Telephony on Linux. A stack overflow bug is triggered within the decodestatusreport function during the SMS decoding. It is assumed that the attack scenario is accessible from a compromised modem, a malicious base station, or just SMS. There is a bound...
CVE-2024-3910
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.91307. Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched...
CVE-2024-3909
A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...
CVE-2024-3910
CVE-2024-3910 affects Tenda AC500 2.0.1.9(1307). The flaw is in the fromDhcpListClient function (file /goform/DhcpListClient) where manipulating the page parameter causes a stack-based buffer overflow. Impact is described as remote code execution with high severity/impact across confidentiality, ...
CVE-2024-3905
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely...
CVE-2024-3906
CVE-2024-3906 affects Tenda AC500 (version 2.0.1.9(1307)) via the formQuickIndex function in /goform/QuickIndex. The root cause is a stack-based buffer overflow triggered when the PPPOEPassword parameter is manipulated, enabling remote exploitation. Publicized exploit details indicate in-the-wild...
CVE-2024-3905
CVE-2024-3905 affects Tenda AC500 2.0.1.9(1307). The flaw is in the R7WebsSecurityHandler function of the /goform/execCommand file, where manipulating the password argument causes a stack-based buffer overflow. It is exploitable remotely, and public exploits have been disclosed. Mitigations docum...
PT-2024-3216
Name of the Vulnerable Software and Affected Versions Tenda W15E version 15.11.0.14 Description A critical issue affects the formIPMacBindDel function in the /goform/delIpMacBind file, where manipulation of the IPMacBindIndex argument leads to a stack-based buffer overflow. This can be exploited...
CVE-2024-32293: Stack-based Buffer Overflow
Tenda W30E v1.0 V1.0.1.25633 firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function...
CVE-2023-5407: Stack-based Buffer Overflow
Controller denial of service due to improper handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5403: Stack-based Buffer Overflow
Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5401: Stack-based Buffer Overflow
Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5395: Stack-based Buffer Overflow
Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2024-3907: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
CVE-2024-3906: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-3905: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC500 2.0.1.91307. It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely...
CVE-2024-3910: Stack-based Buffer Overflow
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.91307. Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched...
CVE-2024-3909: Stack-based Buffer Overflow
A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...
CVE-2024-32317: Stack-based Buffer Overflow
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function...