37080 matches found
PT-2026-46781
Inappropriate implementation in Permissions in Google Chrome prior to 149.0.7827.53 allowed a remote attacker to perform UI spoofing via a crafted HTML page. Chromium security severity: Low...
Security Bulletin: Vulnerabilities have been identified in IBM WebSphere Application Server shipped with IBM Buinses Automation Workflow (CVE-2026-9311, CVE-2026-9330, CVE-2026-9319, CVE-2026-8644)
Summary WebSphere Application Server is shipped as a component of IBM Business Automation Workflow. Information about security vulnerabilities affecting IBM WebSphere Application Server Traditional have been published in security bulletins. Vulnerability Details Refer to the security bulletins...
Security Bulletin: IBM Maximo Application Suite uses WebSphere Application Server Liberty which is vulnerable to CVE-2026-3621.
Summary IBM Maximo Application Suite uses WebSphere Application Server Liberty which is vulnerable to CVE-2026-3621. This bulletin contains information regarding the vulnerability and its fixture. Vulnerability Details CVEID:CVE-2026-3621 DESCRIPTION: IBM WebSphere Application Server - Liberty...
CVE-2026-44546 Header injection via WebSocket upgrade parser differential allows ASGI scope header spoofing
daphne before 4.2.2 reconstructs a raw HTTP request from Twisted's parsed headers and feeds it to autobahn for WebSocket handshake processing. Twisted does not treat \x0b, \x0c, \x1c, \x1d, \x1e, or \x85 as header line separators, but autobahn decodes header values to str and calls splitlines. An...
CVE-2026-44546
The vulnerability (CVE-2026-44546) affects the Daphne web server prior to 4.2.2. It stems from a parser differential between Twisted and Autobahn: Twisted does not treat certain bytes (0x0b, 0x0c, 0x1c, 0x1d, 0x1e, 0x85) as header separators, while Autobahn decodes header values to str and calls ...
Sender-binding gaps in to-device messages
The matrix-sdk-crypto crate before 0.16.1 is missing a check for the sender's user ID when decrypting an Olm-encrypted to-device message containing the senderdevicekeys property. This could be exploited to spoof the sender of an encrypted to-device message, but only if the attacker colludes with ...
SUSE-SU-2026:2229-1 Security update for hplip
This update for hplip fixes the following issues Security issues: - CVE-2025-43023: weak code signing DSA key used to generate package signatures can lead to key spoofing and malicious software installation bsc1266031. - CVE-2026-8631: escalation of privileges and/or arbitrary code execution via ...
Security Bulletin: IBM WebSphere Application Server shipped with Jazz for Service Management (JazzSM) is affected by an identity spoofing vulnerability
Summary IBM WebSphere Application Server shipped with Jazz for Service Management JazzSM is affected by an identity spoofing vulnerability CVE-2026-8644 Vulnerability Details Refer to the security bulletins listed in the Remediation/Fixes section Affected Products and Versions Affected Products|...
samba: group policy certificate enrollment uses http:// without validation
A flaw was found in Samba’s certificate auto-enrollment Group Policy handling. When certificate auto-enrollment is enabled, Samba may retrieve a CA certificate over an unencrypted HTTP connection and install it into the local trust store without proper verification. An attacker with the ability t...
firefox: Spoofing issue in the Form Autofill component
A flaw was found in Firefox. The Mozilla Foundation's Security Advisory describes the following issue: Spoofing issue in the Form Autofill component...
The vulnerability of the ASGI component of the Django web application framework allows attackers to perform spoofing attacks.
The vulnerability of the ASGI component of the Django web application framework involves bypassing authentication through spoofing. Exploiting this vulnerability allows a malicious actor to carry out spoofing attacks remotely...
PT-2026-46306
Name of the Vulnerable Software and Affected Versions matrix-sdk-ui versions prior to 0.16.1 Description The message edit validation logic is missing a check when replacing an encrypted event, as the replacement event is not required to be encrypted. This allows a malicious homeserver administrat...
CVE-2026-46414
Microsoft UFO open-source framework for intelligent automation across devices and platforms. In 3.0.1-4-ge2626659, Microsoft UFO's WebSocket control plane trusts client-supplied identity and role fields in task messages. A client connection can register as a normal device, but later send a TASK...
Security Bulletin: A security vulnerability has been identified in IBM WebSphere Application Server shipped with IBM WebSphere Remote Server (CVE-2026-8644)
Summary IBM WebSphere Application Server is shipped with IBM WebSphere Remote Server. Information about a security vulnerability affecting IBM WebSphere Application Server has been published in a security bulletin. Vulnerability Details Refer to the security bulletins listed in the...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
EUVD-2019-20156
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 monitors running VG4.1.1, VG4.0.3, and lower are affected by network message handling vulnerabilities. The issue allows network-adjacent attackers to spoof or tamper with data and to cause denial-of-service conditions. If an attacker ...
CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...