3750 matches found
CVE-2019-4093
IBM Spectrum Protect (formerly Tivoli Storage Manager) Backup-Archive Client Web UI on Windows (version 8.1.7) is affected by CVE-2019-4093, caused by incorrect file permissions that could allow a user to restore files and directories they should not access. IBM’s security bulletin lists a CVSS v...
CVE-2019-4093
IBM Tivoli Storage Manager IBM Spectrum Protect 8.1.7 could allow a user to restore files and directories using IBM Spectrum Prootect Client Web User Interface on Windows that they should not have access to due to incorrect file permissions. IBM X-Force ID: 157981...
IBM Spectrum Protect CVE-2018-1853 Clickjacking Vulnerability
Description IBM Spectrum Protect is prone to an clickjacking vulnerability. Successful exploits will allow an authenticated attacker to compromise the affected application or obtain sensitive information. Other attacks are also possible. Technologies Affected IBM Spectrum Protect Backup-Archive...
Security Bulletin: Multiple vulnerabilities in IBM Java SDK affect IBM Spectrum LSF Process Manager
Summary There are multiple vulnerabilities in IBM®Runtime Environment Java™Version 8 used by IBM Spectrum LSF Process Manager. IBM Spectrum LSF Process Manager has addressed the applicable CVEs. Vulnerability Details CVEID: CVE-2018-11212 DESCRIPTION: libjpeg is vulnerable to a denial of service,...
Security Bulletin: A vulnerability in IBM WebSphere Application Server affects IBM Spectrum Scale packaged in IBM Elastic Storage Server (CVE-2018-8039)
Summary There is a vulnerability in IBM WebSphere Application Server, used by IBM Spectrum Scale. This issue may allow a remote attacker to conduct a man-in-the-middle attack. Vulnerability Details CVEID: CVE-2018-8039 DESCRIPTION: Apache CXF could allow a remote attacker to conduct a...
CVE-2014-5432
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...
Hardcoded credentials
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...
Design/Logic Flaw
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16, which may allow an attacker to gain access the hos...
CVE-2014-5431
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...
CVE-2014-5433
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16, which may allow an attacker to gain access the hos...
Command injection
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...
CVE-2014-5431
CVE-2014-5431 affects Baxter SIGMA Spectrum Infusion System 6.05 with Wireless Battery Module 16. The issue is a hard-coded password that grants access to WBM management functions, enabling unauthorized configuration changes (e.g., wireless status and phase-complete audible alarm). The vulnerabil...
CVE-2014-5434
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...
Hardcoded credentials
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...
CVE-2014-5432
CVE-2014-5432 affects Baxter SIGMA Spectrum Infusion System v6.05 (model 35700BAX) with Wireless Battery Module (WBM) v16. The root cause includes unauthenticated remote SSH access (Port 22) and related credential exposure. Consequences: remote attacker could modify WBM configuration and retrieve...
CVE-2014-5432
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...
CVE-2014-5433
CVE-2014-5433 affects Baxter’s SIGMA Spectrum Infusion System (Version 6.05, model 35700BAX) with the Wireless Battery Module (WBM) Version 16. The connected disclosures describe multiple issues: a hard-coded password enabling unauthorized management access (CWE-259), an authentication bypass tie...
CVE-2014-5433
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16, which may allow an attacker to gain access the hos...
CVE-2014-5434
The CVE-2014-5434 entry concerns Baxter’s SIGMA Spectrum Infusion System: version 6.05 (model 35700BAX) with Wireless Battery Module (WBM) version 16, which contains a default, hard-coded credential used with FTP. The vulnerability allows remote access in some vectors (three vulnerabilities remot...
CVE-2014-5434
Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...