Lucene search
K

34 matches found

RedhatCVE
RedhatCVE
added 2026/01/09 9:20 a.m.6 views

CVE-2021-33882

A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands...

8.6CVSS7.2AI score0.00196EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2021-20555

Malware in sbrugna...

8.6CVSS8.6AI score0.00196EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2021-20556

Malware in sbrugna...

7.5CVSS7.6AI score0.00337EPSS
Exploits1References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.0 views

EUVD-2021-20559

Malware in sbrugna...

8.8CVSS8.7AI score0.01325EPSS
Exploits1References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2021-20558

Malware in sbrugna...

10CVSS9.2AI score0.06921EPSS
Exploits1References3
RedhatCVE
RedhatCVE
added 2025/05/22 7:49 p.m.6 views

CVE-2021-33884

An Unrestricted Upload of File with Dangerous Type vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows remote attackers to upload any files to the /tmp directory of the device through the webpage API. This can result in critical files being overwritten...

9.1CVSS7.1AI score0.00447EPSS
Exploits1References1
CNVD
CNVD
added 2021/08/27 12:0 a.m.16 views

B. Braun SpaceCom2 has an unspecified vulnerability

B. Braun SpaceCom2, a hardware device from B. Braun, is used to connect to external devices to record data in a patient data management system, PC or USB memory stick.A security vulnerability exists in previous versions of B. Braun SpaceCom2 012U000062, which stems from the fact that publicly...

7.5CVSS2.9AI score0.00337EPSS
Exploits1References1
CNVD
CNVD
added 2021/08/27 12:0 a.m.20 views

B. Braun SpaceCom2 Access Control Error Vulnerability

B. Braun SpaceCom2, a hardware device from B. Braun, is used to connect to external devices to record data in a patient data management system, PC or USB stick.An access control error vulnerability exists in previous versions of B. Braun SpaceCom2 012U000062, which stems from a lack of...

8.6CVSS3.9AI score0.00196EPSS
Exploits0References1
CNVD
CNVD
added 2021/08/27 12:0 a.m.14 views

B. Braun SpaceCom2 input validation error vulnerability

B. Braun SpaceCom2, a hardware device from B. Braun, is used to connect to an external device to record data in a patient data management system, PC, or USB memory stick. A remote, unauthenticated attacker could use this vulnerability to gain user-level command-line access by passing a raw extern...

8.8CVSS2.8AI score0.01325EPSS
Exploits1References1
OSV
OSV
added 2021/08/25 12:15 p.m.2 views

CVE-2021-33886

An improper sanitization of input vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to gain user-level command-line access by passing a raw external string straight through to printf statements. The attacker is required to be on the same network as t...

8.8CVSS5.8AI score0.01325EPSS
Exploits1References2
NVD
NVD
added 2021/08/25 12:15 p.m.14 views

CVE-2021-33886

An improper sanitization of input vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to gain user-level command-line access by passing a raw external string straight through to printf statements. The attacker is required to be on the same network as t...

8.8CVSS0.01325EPSS
Exploits1References2
NVD
NVD
added 2021/08/25 12:15 p.m.14 views

CVE-2021-33885

An Insufficient Verification of Data Authenticity vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to send the device malicious data that will be used in place of the correct data. This results in full system command access and execution because of...

10CVSS0.06921EPSS
Exploits1References2
OSV
OSV
added 2021/08/25 12:15 p.m.3 views

CVE-2021-33884

An Unrestricted Upload of File with Dangerous Type vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows remote attackers to upload any files to the /tmp directory of the device through the webpage API. This can result in critical files being overwritten...

9.1CVSS7.6AI score0.00447EPSS
Exploits1References2
OSV
OSV
added 2021/08/25 12:15 p.m.1 views

CVE-2021-33885

An Insufficient Verification of Data Authenticity vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to send the device malicious data that will be used in place of the correct data. This results in full system command access and execution because of...

9.8CVSS7.7AI score
Exploits0References2
NVD
NVD
added 2021/08/25 12:15 p.m.9 views

CVE-2021-33883

A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration...

7.5CVSS0.00337EPSS
Exploits1References2
OSV
OSV
added 2021/08/25 12:15 p.m.2 views

CVE-2021-33882

A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands...

8.6CVSS5.8AI score
Exploits0References2
NVD
NVD
added 2021/08/25 12:15 p.m.15 views

CVE-2021-33882

A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands...

8.6CVSS0.00196EPSS
Exploits0References2
Prion
Prion
added 2021/08/25 12:15 p.m.12 views

Unrestricted file upload

An Unrestricted Upload of File with Dangerous Type vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows remote attackers to upload any files to the /tmp directory of the device through the webpage API. This can result in critical files being overwritten...

5CVSS9.2AI score0.00447EPSS
Exploits1References2Affected Software1
Prion
Prion
added 2021/08/25 12:15 p.m.10 views

Authentication flaw

A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands...

5CVSS9AI score0.00196EPSS
Exploits0References2Affected Software1
Prion
Prion
added 2021/08/25 12:15 p.m.13 views

Design/Logic Flaw

A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration...

5CVSS7.7AI score0.00337EPSS
Exploits1References2Affected Software1
Rows per page
Query Builder