Lucene search
+L

2290 matches found

Cvelist
Cvelist
added 2022/10/19 12:00 a.m.37 views

CVE-2022-35860

Missing AES encryption in Corsair K63 Wireless 3.1.3 allows physically proximate attackers to inject and sniff keystrokes via 2.4 GHz radio transmissions...

6.8AI score0.00222EPSS
SaveExploits1References3
NVD
NVD
added 2022/09/26 11:15 a.m.26 views

CVE-2022-36159

Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...

8.8CVSS0.00975EPSS
SaveExploits1References4
Prion
Prion
added 2022/09/26 11:15 a.m.22 views

Design/Logic Flaw

Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...

5.8CVSS8.8AI score0.00975EPSS
SaveExploits1References4Affected Software4
Cvelist
Cvelist
added 2022/09/26 10:07 a.m.35 views

CVE-2022-36159

Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...

9.1AI score0.00975EPSS
SaveExploits1References4
Hacker One
Hacker One
added 2022/09/22 2:19 p.m.29 views

Nextcloud: Vulnerable moment-timezone version shipped

An information exposure vulnerability was found in the moment-timezone package used by Nextcloud server. Attackers could sniff network traffic during data transmission, making exploitation easier. The vulnerability was patched in version 0.5.35 by changing the FTP endpoint with an HTTPS endpoint...

6.8AI score
SaveExploits0
CNNVD
CNNVD
added 2022/09/13 12:00 a.m.9 views

IBM Control Desk 安全漏洞

IBM Control Desk is an application from International Business Machines IBM. Automated service management and seamlessly integrated, best-practice based service desk functionality. A security vulnerability exists in IBM Control Desk version 7.6.1, which stems from the fact that it does not set...

4.3CVSS5.1AI score0.00598EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2022/08/31 3:33 p.m.29 views

CVE-2022-2758 Update

Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems LSIS Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all...

6.5CVSS6.7AI score0.00382EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/08/31 12:00 a.m.13 views

PT-2022-18501 · Ls Electric · Xgb-Xbch +6

Name of the Vulnerable Software and Affected Versions: LS Electric XG5000 software versions prior to V4.0 LS Electric PLCs: XGK-CPUU/H/A/S/E versions prior to V3.50 XGI-CPUU/UD/H/S/E versions prior to V3.20 XGR-CPUH versions prior to V1.80 XGB-XBMS versions prior to V3.00 XGB-XBCH versions prior ...

6.5CVSS6.1AI score0.00382EPSS
SaveExploits0References3
OSV
OSV
added 2022/08/29 3:15 p.m.8 views

CVE-2022-36200

In FiberHome VDSL2 Modem HG150-UbV3.0, Credentials of Admin are submitted in URL, which can be logged/sniffed...

7.5CVSS5.8AI score0.02326EPSS
SaveExploits1References2
ATTACKERKB
ATTACKERKB
added 2022/08/29 3:15 p.m.20 views

CVE-2022-36200

In FiberHome VDSL2 Modem HG150-UbV3.0, Credentials of Admin are submitted in URL, which can be logged/sniffed...

7.5CVSS7.1AI score0.02326EPSS
SaveExploits1References3
Prion
Prion
added 2022/08/29 3:15 p.m.25 views

Design/Logic Flaw

In FiberHome VDSL2 Modem HG150-UbV3.0, Credentials of Admin are submitted in URL, which can be logged/sniffed...

5CVSS7.5AI score0.02326EPSS
SaveExploits1References2Affected Software1
CVE
CVE
added 2022/08/29 2:21 p.m.79 views

CVE-2022-36200

CVE-2022-36200 affects FiberHome VDSL2 Modem HG150-Ub_V3.0. The admin credentials are submitted in the URL, creating risk of logging/sniffing and exposure of confidential data. The vulnerability is described across multiple sources (NVD entry mirrors a network-accessible issue with high impact on...

7.5CVSS7.5AI score0.02326EPSS
SaveExploits1References2Affected Software1
NVD
NVD
added 2022/07/12 9:15 p.m.25 views

CVE-2022-35228

SAP BusinessObjects CMC allows an unauthenticated attacker to retrieve token information over the network which would otherwise be restricted. This can be achieved only when a legitimate user accesses the application and a local compromise occurs, like sniffing or social engineering. On successfu...

8.8CVSS0.00539EPSS
SaveExploits0References2
NVD
NVD
added 2022/06/28 2:15 p.m.32 views

CVE-2022-30563

When an attacker uses a man-in-the-middle attack to sniff the request packets with success logging in through ONVIF, he can log in to the device by replaying the user's login packet...

7.4CVSS0.00943EPSS
SaveExploits1References1
Cvelist
Cvelist
added 2022/06/28 1:44 p.m.45 views

CVE-2022-30563

When an attacker uses a man-in-the-middle attack to sniff the request packets with success logging in through ONVIF, he can log in to the device by replaying the user's login packet...

7.5AI score0.00943EPSS
SaveExploits1References1
Cvelist
Cvelist
added 2022/06/28 1:42 p.m.28 views

CVE-2022-30561

When an attacker uses a man-in-the-middle attack to sniff the request packets with success logging in, the attacker could log in to the device by replaying the user's login packet...

5.8AI score0.00734EPSS
SaveExploits0References1
OSV
OSV
added 2022/06/08 3:15 p.m.15 views

CVE-2022-24296

Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...

7.5CVSS5.8AI score0.01121EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/06/08 12:00 a.m.16 views

Mitsubishi Electric Air Conditioning System 加密问题漏洞

Mitsubishi Electric Air Conditioning System is an air conditioning management system from Mitsubishi Electric, a Japanese company. A security vulnerability exists in the Mitsubishi Electric Air Conditioning System. An unauthenticated, remote attacker could cause the air conditioning system's...

7.5CVSS6.8AI score0.01121EPSS
SaveExploits0References6
CNVD
CNVD
added 2022/05/26 12:00 a.m.30 views

Open Automation Software OAS Platform信息泄露漏洞(CNVD-2022-58682)

Open Automation Software OAS Platform is an industrial Internet of Things IoT suite from Open Automation Software, Inc. Open Automation Software OAS Platform version V16.00.0112 is vulnerable to information disclosure and can be exploited by attackers to obtain sensitive information via targeted...

7.5CVSS4.2AI score0.01138EPSS
SaveExploits1References1
OSV
OSV
added 2022/05/25 9:15 p.m.9 views

CVE-2022-26077

A cleartext transmission of sensitive information vulnerability exists in the OAS Engine configuration communications functionality of Open Automation Software OAS Platform V16.00.0112. A targeted network sniffing attack can lead to a disclosure of sensitive information. An attacker can sniff...

7.5CVSS5.8AI score0.01138EPSS
SaveExploits1References1
Rows per page