CVE-2025-40582

The CVE-2025-40582 entry concerns Siemens SCALANCE LPE9403 devices with SINEMA Remote Connect Edge Client installed. The vulnerability arises from improper sanitization of configuration parameters, enabling a non-privileged local attacker to execute root commands on the device. Affected products ...

8.5CVSS7.2AI score0.00188EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2025/05/13 9:39 a.m.•27 views

CVE-2025-40582

A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V2.1 HF0 with SINEMA Remote Connect Edge Client installed. Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the...

8.5CVSS0.00188EPSS
SaveExploits0References1
CVE
CVE
•added 2025/05/13 9:39 a.m.•85 views

CVE-2025-40581

The CVE-2025-40581 affects Siemens SCALANCE LPE9403 devices when SINEMA Remote Connect Edge Client is installed. Affected component is the authentication mechanism, with the root cause described as an authentication bypass that permits a local, non-privileged attacker to bypass authentication and...

8.4CVSS6.7AI score0.00159EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2025/05/13 9:38 a.m.•33 views

CVE-2025-30174

A vulnerability has been identified in SIMATIC PCS neo V4.1 All versions, SIMATIC PCS neo V5.0 All versions, SINEC NMS All versions V4.0, SINEMA Remote Connect All versions, Totally Integrated Automation Portal TIA Portal V17 All versions, Totally Integrated Automation Portal TIA Portal V18 All...

8.7CVSS0.0065EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/05/13 12:00 a.m.•21 views

Siemens多款产品 缓冲区错误漏洞

Siemens SINEMA Remote Connect and others are products of Siemens, Germany.Siemens SINEMA Remote Connect is a set of remote management platforms.Siemens SINEC NMS is a network management system NMS.Siemens SIMATIC PCS is a process control system. A buffer error vulnerability exists in several...

8.7CVSS7AI score0.0065EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2025/05/13 12:00 a.m.•19 views

PT-2025-20877

Name of the Vulnerable Software and Affected Versions SCALANCE LPE9403 versions with SINEMA Remote Connect Edge Client installed Description A vulnerability has been identified in SCALANCE LPE9403 devices with SINEMA Remote Connect Edge Client installed. Affected devices do not properly sanitize...

8.5CVSS6.4AI score0.00188EPSS
SaveExploits0References8
CNNVD
CNNVD
•added 2025/05/13 12:00 a.m.•20 views

Siemens多款产品 缓冲区错误漏洞

Siemens SINEMA Remote Connect and others are products of Siemens, Germany.Siemens SINEMA Remote Connect is a set of remote management platforms.Siemens SINEC NMS is a network management system NMS.Siemens SIMATIC PCS is a process control system. A buffer error vulnerability exists in several...

8.7CVSS7AI score0.0065EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2025/05/13 12:00 a.m.•18 views

PT-2025-20876

Name of the Vulnerable Software and Affected Versions: SCALANCE LPE9403 versions with SINEMA Remote Connect Edge Client installed Description: A vulnerability has been identified that allows a non-privileged local attacker to bypass the authentication of the SINEMA Remote Connect Edge Client, and...

8.4CVSS6.3AI score0.00159EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2025/05/13 12:00 a.m.•26 views

PT-2025-20878

Name of the Vulnerable Software and Affected Versions SCALANCE LPE9403 versions with SINEMA Remote Connect Edge Client installed Description A vulnerability has been identified in SCALANCE LPE9403, where affected devices transmit sensitive information in cleartext. This could allow a privileged...

6.7CVSS5.8AI score0.00114EPSS
SaveExploits0References8
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•5 views

CVE-2025-40582: Improper Neutralization of Special Elements used in an OS Command

A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V2.1 HF0 with SINEMA Remote Connect Edge Client installed. Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the...

8.5CVSS7.2AI score0.00188EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•8 views

CVE-2025-40583: Cleartext Transmission of Sensitive Information

A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V2.1 HF0 with SINEMA Remote Connect Edge Client installed. Affected devices do transmit sensitive information in cleartext. This could allow a privileged local attacker to retrieve this sensitive information...

6.7CVSS5.4AI score0.00114EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•6 views

CVE-2025-40581: Authentication Bypass Using an Alternate Path or Channel

A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V2.1 HF0 with SINEMA Remote Connect Edge Client installed. Affected devices are vulnerable to an authentication bypass. This could allow a non-privileged local attacker to bypass the authentication of the SINE...

8.4CVSS6.7AI score0.00159EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•11 views

CVE-2025-30176: Out-of-bounds Read

A vulnerability has been identified in SIMATIC PCS neo V4.1 All versions, SIMATIC PCS neo V5.0 All versions, SINEC NMS All versions V4.0, SINEMA Remote Connect All versions, Totally Integrated Automation Portal TIA Portal V17 All versions, Totally Integrated Automation Portal TIA Portal V18 All...

8.7CVSS7.2AI score0.0065EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•9 views

CVE-2025-30174: Out-of-bounds Read

A vulnerability has been identified in SIMATIC PCS neo V4.1 All versions, SIMATIC PCS neo V5.0 All versions, SINEC NMS All versions V4.0, SINEMA Remote Connect All versions, Totally Integrated Automation Portal TIA Portal V17 All versions, Totally Integrated Automation Portal TIA Portal V18 All...

8.7CVSS7.2AI score0.0065EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/13 12:00 a.m.•9 views

CVE-2025-30175: Out-of-bounds Write

A vulnerability has been identified in SIMATIC PCS neo V4.1 All versions, SIMATIC PCS neo V5.0 All versions, SINEC NMS All versions V4.0, SINEMA Remote Connect All versions, Totally Integrated Automation Portal TIA Portal V17 All versions, Totally Integrated Automation Portal TIA Portal V18 All...

8.7CVSS7.2AI score0.0065EPSS
SaveExploits0References1
NCSC
NCSC
•added 2025/03/11 12:30 p.m.•36 views

Vulnerabilities fixed in Siemens products

Siemens has fixed vulnerabilities in various products such as SCALANCE, SIMATIC, SINAMICS, SINEMA, SiPass, Teamcenter and Tecnomatix. The vulnerabilities potentially enable a malicious person to carry out attacks that can lead to the following categories of damage: - Denial-of-Service DoS -...

9.8CVSS7.8AI score0.15379EPSS
SaveExploits0References11
ICS
ICS
•added 2025/03/11 12:00 a.m.•27 views

Siemens SINEMA Remote Connect Server

SUMMARY SINEMA Remote Connect Server before V3.2 SP3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends...

9.5AI score
SaveExploits0References10
ICS
ICS
•added 2025/03/11 12:00 a.m.•32 views

Siemens SINEMA Remote Connect Client

SUMMARY SINEMA Remote Connect Client before V3.2 SP3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends...

9.4AI score
SaveExploits0References10
RedhatCVE
RedhatCVE
•added 2025/02/06 1:58 a.m.•35 views

CVE-2022-25311

A vulnerability has been identified in SINEC NMS All versions = V1.0.3 V2.0, SINEC NMS All versions V1.0.3, SINEMA Server V14 All versions. The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This coul...

8.8CVSS6.4AI score0.00537EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/02/05 11:14 p.m.•24 views

CVE-2022-32251

A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.1. There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an...