Lucene search
+L

93 matches found

osv_cve
osv_cve
•added 2020/08/31 3:15 p.m.•26 views

CVE-2020-13593

The Bluetooth Low Energy Secure Manager Protocol SMP implementation in Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK through 2.2.3 allows the Diffie-Hellman check during the Secure Connection pairing to be skipped if the Link Layer encryption setup is performed earlier. An attacker in radi...

8.8CVSS5.9AI score0.00259EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2020/08/31 2:54 p.m.•47 views

CVE-2020-13593

The Bluetooth Low Energy Secure Manager Protocol SMP implementation in Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK through 2.2.3 allows the Diffie-Hellman check during the Secure Connection pairing to be skipped if the Link Layer encryption setup is performed earlier. An attacker in radi...

8.9AI score0.00259EPSS
SaveExploits0References3
CVE
CVE
•added 2020/08/31 2:54 p.m.•91 views

CVE-2020-13593

The CVE-2020-13593 entry concerns TI’s SimpleLink CC2640R2-SDK (up to v2.2.3) where the Bluetooth Low Energy SMP implementation allows the Diffie-Hellman check to be skipped if Link Layer encryption is set up earlier. This enables an attacker within radio range to establish an encrypted session w...

8.8CVSS8.8AI score0.00259EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/08/31 12:00 a.m.•12 views

CVE-2020-13593: Improper Verification of Cryptographic Signature

The Bluetooth Low Energy Secure Manager Protocol SMP implementation in Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK through 2.2.3 allows the Diffie-Hellman check during the Secure Connection pairing to be skipped if the Link Layer encryption setup is performed earlier. An attacker in radi...

8.8CVSS5.9AI score0.00259EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/08/31 12:00 a.m.•16 views

PT-2020-13611

Name of the Vulnerable Software and Affected Versions Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK versions 2.2.3 and earlier Description The Bluetooth Low Energy Secure Manager Protocol implementation has a flaw that allows an attacker in radio range to skip the Diffie-Hellman check duri...

8.8CVSS0.00259EPSS
SaveExploits0References5
Prion
Prion
•added 2020/02/10 9:51 p.m.•37 views

Cross site request forgery (csrf)

The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers i...

6.1CVSS6.7AI score0.00709EPSS
SaveExploits0References2Affected Software2
CVE
CVE
•added 2020/02/10 8:33 p.m.•150 views

CVE-2019-19193

CVE-2019-19193 affects TI Bluetooth Low Energy peripheral in SIMPLELINK-CC2640R2-SDK (up to 3.30.00.20) and BLE-STACK (up to 1.5.0) for CC2640R2 and CC2540/1. The issue is that the advertisement connection request packet is not properly restricted on reception, allowing attackers in radio range t...

6.5CVSS6.4AI score0.00709EPSS
SaveExploits0References2Affected Software2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/10 12:00 a.m.•11 views

CVE-2019-19193: Undefined Security Weakness

The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers i...

6.5CVSS6.7AI score0.00709EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2020/02/10 12:00 a.m.•12 views

PT-2020-10082

Name of the Vulnerable Software and Affected Versions Texas Instruments SIMPLELINK-CC2640R2-SDK versions 3.30.00.20 and earlier Texas Instruments BLE-STACK versions 1.5.0 and earlier Description The Bluetooth Low Energy peripheral implementation does not properly restrict the advertisement...

6.5CVSS0.00709EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2018/11/06 4:00 p.m.•64 views

CVE-2018-16986

Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow...

8.7AI score0.02872EPSS
SaveExploits0References6
NVD
NVD
•added 2018/11/06 3:29 p.m.•53 views

CVE-2018-16986

Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow...

8.8CVSS8.2AI score0.02872EPSS
SaveExploits0References6
Prion
Prion
•added 2018/11/06 3:29 p.m.•46 views

Buffer overflow

Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow...

5.8CVSS8.3AI score0.02872EPSS
SaveExploits0References6Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/11/06 12:00 a.m.•15 views

CVE-2018-16986: Out-of-bounds Write

Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow...

8.8CVSS8.6AI score0.02872EPSS
SaveExploits0References2
Rows per page
Query Builder