Lucene search
+L

4190 matches found

CNNVD
CNNVD
added 2024/05/14 12:0 a.m.11 views

Siemens多款产品 缓冲区错误漏洞

S7 PCT Port Configuration Tool is a PC-based software for parameterizing Siemens IO link master modules and third-party IO link devices.Security Configuration Tool SCT is an engineering software for security devices such as the SCALANCE-S or CP 443- 1Advanced.SIMATIC Automation Tool allows...

8.2CVSS6.6AI score0.00262EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.10 views

Siemens SIMATIC CN 4100 安全漏洞

The Siemens SIMATIC CN 4100 is a communication node from Siemens, Germany. A security vulnerability exists in the Siemens SIMATIC CN 4100 because the affected device contains an unrestricted USB port. An attacker can exploit the vulnerability to potentially misuse the port to boot another operati...

7.6CVSS6.9AI score0.00394EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.7 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A security vulnerability exists in Siemens SIMATIC RTLS Locating Manager due to an affected SIMATIC RTLS Locating Manager clien...

8.8CVSS6.7AI score0.00307EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.6 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A plaintext transfer of sensitive information vulnerability exists in Siemens SIMATIC RTLS Locating Manager due to the affected...

9.6CVSS6.4AI score0.00272EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.6 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A vulnerability exists in Siemens SIMATIC RTLS Locating Manager due to an incorrect assignment of critical resource privileges...

6.3CVSS6.5AI score0.00201EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.8 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. Siemens SIMATIC RTLS Locating Manager suffers from an incorrect assignment of critical resource privileges vulnerability, which...

9.4CVSS6.8AI score0.00458EPSS
SaveExploits0References3
ICS
ICS
added 2024/05/14 12:0 a.m.45 views

Siemens SIMATIC RTLS Locating Manager

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS9.6AI score0.03332EPSS
SaveExploits0References12
ICS
ICS
added 2024/05/14 12:0 a.m.53 views

Siemens SIMATIC CN 4100

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

10CVSS9.5AI score0.00703EPSS
SaveExploits0References12
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.5 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A security vulnerability exists in Siemens SIMATIC RTLS Locating Manager because the affected SIMATIC RTLS Locating Manager Tra...

6.3CVSS6.7AI score0.00151EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.6 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A resource allocation error vulnerability exists in Siemens SIMATIC RTLS Locating Manager due to the affected application faili...

7.1CVSS6.6AI score0.00637EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.4 views

Siemens 多款产品 安全漏洞

SIMATIC RTLS Locating Manager is used to configure, operate and maintain the SIMATIC RTLS unit, a real-time wireless positioning system that provides locating solutions. A security vulnerability exists in Siemens SIMATIC RTLS Locating Manager due to the affected system's use of symmetric ciphers...

10CVSS6.7AI score0.00836EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/05/14 12:0 a.m.32 views

Siemens SIMATIC CN 4100 信任管理问题漏洞

The Siemens SIMATIC CN 4100 is a communication node from Siemens, Germany. A security vulnerability exists in the Siemens SIMATIC CN 4100 due to an affected device containing undocumented users and credentials. An attacker could exploit the vulnerability to misuse the credentials to compromise th...

9.8CVSS6.7AI score0.00703EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2024/05/14 12:0 a.m.9 views

PT-2024-4507 · Siemens · Simatic Rtls Locating Manager

Name of the Vulnerable Software and Affected Versions: SIMATIC RTLS Locating Manager versions prior to V3.0.1.1 Description: The affected application does not properly limit the size of specific logs, which could allow an unauthenticated remote attacker to exhaust system resources by creating a...

7.1CVSS7.1AI score0.00637EPSS
SaveExploits0References4
NCSC
NCSC
added 2024/05/14 12:0 a.m.14 views

Vulnerabilities fixed in Siemens products

Siemens has fixed vulnerabilities in several products including. Parasolid, Ruggedcom, SIMATIC, SICAM and Tecnomatix. The vulnerabilities potentially enable a malicious person to launch attacks execute attacks that could result in the following categories of damage: Denial-of-Service DoS...

10CVSS7.3AI score0.78483EPSS
SaveExploits12
CNNVD
CNNVD
added 2024/05/03 12:0 a.m.9 views

Softing edgeConnector 安全漏洞

Softing edgeConnector is a Docker-based software application from Softing Inc. It can access process data in SIMATIC S7, SINUMERIK 840D and Modbus TCP controllers. A security vulnerability exists in Softing edgeConnector that originates from a dereferenced null pointer in the handling of OPC clie...

7.5CVSS7.5AI score0.00812EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/05/03 12:0 a.m.9 views

Softing edgeConnector 安全漏洞

Softing edgeConnector is a Docker-based software application from Softing Inc. It can access process data in SIMATIC S7, SINUMERIK 840D and Modbus TCP controllers. A security vulnerability exists in Softing edgeConnector that stems from a specific flaw in the handling of OPC UA ConditionRefresh...

7.5CVSS7.5AI score0.01442EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/04/22 12:0 a.m.33 views

Siemens SIMATIC Devices Improper Input Validation (CVE-2023-6121)

An out-of-bounds read vulnerability was found in the NVMe-oF/TCP subsystem in the Linux kernel. This issue may allow a remote attacker to send a crafted TCP packet, triggering a heap-based buffer overflow that results in kmalloc data being printed and potentially leaked to the kernel ring buffer...

4.3CVSS6.7AI score0.01657EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2024/04/22 12:0 a.m.24 views

Siemens SIMATIC Devices Improper Input Validation (CVE-2023-45898)

The Linux kernel before 6.5.4 has an es1 use-after-free in fs/ext4/extentsstatus.c, related to ext4esinsertextent. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...

7.8CVSS7.5AI score0.00274EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2024/04/22 12:0 a.m.45 views

Siemens SIMATIC and SCALANCE Devices Improper Input Validation (CVE-2024-0727)

Issue summary: Processing a maliciously formatted PKCS12 file may lead OpenSSL to crash leading to a potential Denial of Service attack Impact summary: Applications loading files in the PKCS12 format from untrusted sources might terminate abruptly. A file in PKCS12 format can contain certificates...

5.5CVSS6.3AI score0.03187EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
added 2024/04/22 12:0 a.m.29 views

Siemens SIMATIC and SCALANCE Devices Improper Check for Unusual or Exceptional Conditions (CVE-2023-5678)

Issue summary: Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DHgeneratekey to generate an X9.42 DH key may experience long delays. Likewise, applications that use...

5.3CVSS6.4AI score0.04459EPSS
SaveExploits0References20