4190 matches found
CVE-2023-32736
CVE-2023-32736 affects a wide range of Siemens products (e.g., SIMATIC S7-PLCSIM, STEP 7, WinCC, SINAMICS Startdrive, SIRIUS, TIA Portal Cloud, etc.). Affected software does not properly sanitize user-controllable input when parsing user settings, enabling type confusion and arbitrary code execut...
Siemens多款产品 代码问题漏洞
SIMATIC S7-PLCSIM simulates the S7-1200, S7-1500 and a number of other PLC derivatives shipped as part of SIMATIC STEP 7. simatic step7 TIA Portal is an engineering software package for configuring and programming SIMATIC controllers. simmocode ES is the simmocode ES is the core software package...
The vulnerability of the storage manager Adaptec Maxview for industrial computers SIMATIC IPC1047, SIMATIC IPC1047E, SIMATIC IPC647D, and SIMATIC IPC647E allows attackers to carry out “man-in-the-middle” attacks.
The vulnerability of the data storage manager Adaptec Maxview for industrial computers SIMATIC IPC1047, SIMATIC IPC1047E, SIMATIC IPC647D, and SIMATIC IPC647E is related to the use of a non-unique TLS certificate. Exploiting this vulnerability allows attackers to carry out “man-in-the-middle”...
PT-2024-8716
Name of the Vulnerable Software and Affected Versions SIMATIC CP 1543-1 versions 4.0.44 through 4.0.49 Description The issue is related to improper authorization handling in the SIMATIC CP 1543-1 communication module's firmware. This could allow an unauthenticated remote attacker to bypass existi...
The vulnerability of the web server of the microprogramming software for programmable logic controllers SIMATICS7-1500 and S7-1200 CPU family allows a hacker to redirect users to any desired URL address.
The vulnerability of the web server of the microprogramming software for programmable logic controllers SIMATICS7-1500 and S7-1200 CPUs is related to the redirection of URLs to unreliable websites. Exploiting this vulnerability allows an attacker to remotely redirect users to arbitrary URL...
The vulnerability of the web server of the microprogramming software for communication modules of SIMATIC CP, TIM 1531 IRC, allows a perpetrator to cause service failures.
The vulnerability of the web server of the microprogramming software for communication modules of SIMATIC CP, TIM 1531 IRC, is related to errors in pointer assignment. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a perpetrator to trigger a service failure.
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents is related to lack of access control. Exploiting this vulnerability could allow an intruder to cause service interruptions by creating instances of Ajax2App...
The vulnerability of the microprogrammed software in the SIMATIC S7-200 SMART CPU family, related to uncontrolled resource consumption, allows a intruder to trigger malfunctions during maintenance operations.
The vulnerability of the microprogrammed software in the SIMATIC S7-200 SMART CPU family is related to incorrect processing of TCP packets. Exploiting this vulnerability can allow an attacker to cause malfunctions in the system remotely...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a perpetrator to trigger a service failure and expose the protected information.
The vulnerability of SIMATIC Reader software’s configuration files is related to deficiencies in handling exceptional states. Exploiting this vulnerability can allow an attacker to cause service failures and disclose protected information when a faulty certificate is loaded...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a perpetrator to enable debugging functions.
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents is related to the presence of undocumented configuration commands. Exploiting this vulnerability could allow an attacker to enable debugging functions...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a perpetrator to influence the confidentiality of the protected information.
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents is related to the lack of protection for operational data. Exploiting this vulnerability could allow an attacker, operating remotely, to compromise the confidentiality of the protected information...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a hacker to restart the application.
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents is related to incorrect processing of character definitions during SNMP configuration. Exploiting this vulnerability could allow a malicious actor to remotely restart the application...
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents allows a perpetrator to activate additional functions of the device.
The vulnerability of the SIMATIC Reader software for editing and managing projects and documents is related to the presence of undocumented configuration commands. Exploiting this vulnerability can allow attackers to activate additional functions of the device by modifying the configuration files...
The vulnerability of web-servers of microprogramming software for devices such as SIMATIC CP, SIMATIC HMI, SIMATIC IPC, and SIMATIC WinCC Runtime Advanced DiagBase, as well as SIPLUS TIM, allows a perpetrator to cause service interruptions.
The vulnerability of web-servers of microprogramming software for SIMATIC CP, SIMATIC HMI, SIMATIC IPC, and SIMATIC WinCC Runtime Advanced DiagBase, as well as SIPLUS TIM, is related to errors in variable name assignments. Exploiting this vulnerability can allow attackers to cause system failures...
Siemens Multiple Products URL Redirection Vulnerability
SIMATIC Drive Controllers are designed for the automation of production machines, combining the functionality of SIMATIC S7-1500 CPUs and SINAMICS S120 drive controls. simatic ET 200SP Open Controller is the pc-based version of the SIMATIC S7-1500 controller, including optional visualization and...
Siemens SIMATIC S7-1200和Siemens SIMATIC S7-1500 安全漏洞
SIMATIC Drive Controllers are designed for the automation of production machines, combining the functionality of SIMATIC S7-1500 CPUs and SINAMICS S120 drive controls. simatic ET 200SP Open Controller is the pc-based version of the SIMATIC S7-1500 controller, including optional visualization and...
Siemens SIMATIC S7-1500 CPU 安全漏洞
SIMATIC Drive Controllers are designed for the automation of production machines, combining the functionality of SIMATIC S7-1500 CPUs and SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the pc-based version of the SIMATIC S7-1500 controller, including optional visualization and...
Siemens SIMATIC S7-1500 and S7-1200 CPUs
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
The vulnerability of the web servers of the microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP allows a perpetrator to cause service failures.
The vulnerability of the web servers of the microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP is related to the distribution of resources without any restrictions or regulations. Exploiting this vulnerability could allow a malicious actor to cause...
The vulnerability of the web servers of the microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP allows a perpetrator to cause service interruptions.
The vulnerability of the web servers of microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP is related to the use of memory after it is freed. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...