Lucene search
+L

296 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/11/26 12:00 a.m.•4 views

CVE-2014-8551: Improper Control of Generation of Code

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets...

10CVSS6.5AI score0.05271EPSS
SaveExploits0References2
ICS
ICS
•added 2014/11/07 7:00 a.m.•65 views

Siemens SIMATIC WinCC OA Multiple Vulnerabilities

OVERVIEW Researchers Gleb Gritsai, Ilya Karpov, and Kirill Nesterov of Positive Technologies have identified multiple vulnerabilities in the Siemens SIMATIC WinCC Open Architecture OA application. Siemens has produced updates that mitigate these vulnerabilities. These vulnerabilities could be...

7.5CVSS8AI score0.05261EPSS
SaveExploits3References10
ThreatPost
ThreatPost
•added 2014/10/07 2:49 p.m.•32 views

Siemens Patches Five Vulnerabilities in SIMATIC WinCC for PCS 7

Siemens has patched five vulnerabilities in its SIMATIC PCS 7 system that could result in privilege escalation and give an attacker unauthenticated access to sensitive data. The flaws technically exist in WinCC, a SCADA supervisory control and data acquisition and HMI human-machine interface syst...

6CVSS0.5AI score0.01686EPSS
SaveExploits0References1
NVD
NVD
•added 2014/07/24 2:55 p.m.•36 views

CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during...

6.8CVSS6AI score0.01087EPSS
SaveExploits0References1
NVD
NVD
•added 2014/07/24 2:55 p.m.•42 views

CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control...

4.6CVSS6.5AI score0.00365EPSS
SaveExploits0References1
NVD
NVD
•added 2014/07/24 2:55 p.m.•43 views

CVE-2014-4682

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request...

5CVSS6.1AI score0.01686EPSS
SaveExploits0References1
Prion
Prion
•added 2014/07/24 2:55 p.m.•33 views

Cross site request forgery (csrf)

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a 1 HTTP or 2 HTTPS request...

4.9CVSS6.9AI score0.01222EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2014/07/24 2:55 p.m.•33 views

Cross site request forgery (csrf)

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request...

5CVSS6.6AI score0.01686EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2014/07/24 2:55 p.m.•32 views

Design/Logic Flaw

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...

6CVSS6.9AI score0.01344EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2014/07/24 2:55 p.m.•35 views

Hardcoded credentials

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during...

6.8CVSS6.5AI score0.01087EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2014/07/24 2:00 p.m.•48 views

CVE-2014-4684

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...

6.4AI score0.01344EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2014/07/24 2:00 p.m.•53 views

CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a 1 HTTP or 2 HTTPS request...

6.4AI score0.01222EPSS
SaveExploits0References1
CVE
CVE
•added 2014/07/24 2:00 p.m.•86 views

CVE-2014-4686

Siemens SIMATIC WinCC (before 7.3) contains a hard-coded encryption key in the Project administration component, enabling remote attackers to extract the key from another installation and use it to sniff traffic on TCP port 1030. This can lead to credential exposure and elevated privileges. Publi...

6.8CVSS5.9AI score0.01087EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2014/07/24 2:00 p.m.•53 views

CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control...

6.4AI score0.00365EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2014/07/24 2:00 p.m.•50 views

CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during...

6AI score0.01087EPSS
SaveExploits0References1
CVE
CVE
•added 2014/07/24 2:00 p.m.•87 views

CVE-2014-4685

CVE-2014-4685 affects Siemens SIMATIC WinCC prior to 7.3 (used in PCS7). Root cause: weak system-object access control enabling local privilege escalation for local users. Siemens released fixes in WinCC 7.3 (and PCS7 8.1); upgrading is advised. Other sources note mitigation steps and a broader s...

4.6CVSS6.6AI score0.00365EPSS
SaveExploits0References1Affected Software2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/07/24 12:00 a.m.•4 views

CVE-2014-4685: Undefined Security Weakness

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control...

4.6CVSS5.8AI score0.00365EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/07/24 12:00 a.m.•5 views

CVE-2014-4684: Undefined Security Weakness

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...

6CVSS5.8AI score0.01344EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/07/24 12:00 a.m.•5 views

CVE-2014-4683: Undefined Security Weakness

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a 1 HTTP or 2 HTTPS request...

4.9CVSS5.8AI score0.01222EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/07/24 12:00 a.m.•7 views

CVE-2014-4682: Exposure of Sensitive Information to an Unauthorized Actor

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request...

5CVSS5.8AI score0.01686EPSS
SaveExploits0References2
Rows per page
Query Builder