586 matches found
CVE-2023-23452
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000...
CVE-2023-23450
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to use a password hash instead of an actual password to login to a valid user account via...
CVE-2023-23451
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number =2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number =2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number =2311xxxx all...
CVE-2023-23446
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface...
CVE-2023-23444
Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to...
CVE-2022-43989
Password recovery vulnerability in SICK SIM2x00 ARM Partnumber 1092673 and 1081902 with firmware version = 1.2.0 as soon as possible available in SICK Support Portal...
CVE-2022-46833
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-27578
An attacker can perform a privilege escalation through the SICK OEE if the application is installed in a directory where non authenticated or low privilege users can modify its content...
CVE-2022-46834
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-47377
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version = 1.13.4 as soon as possible available in SICK Support Portal...
CVE-2021-32497
SICK SOPAS ET before version 4.8.0 allows attackers to wrap any executable file into an SDD and provide this to a SOPAS ET user. When a user starts the emulator the executable is run without further checks...
CVE-2021-32499
SICK SOPAS ET before version 4.8.0 allows attackers to manipulate the command line arguments to pass in any value to the Emulator executable...
CVE-2021-32498
SICK SOPAS ET before version 4.8.0 allows attackers to manipulate the pathname of the emulator and use path traversal to run an arbitrary executable located on the host system. When the user starts the emulator from SOPAS ET the corresponding executable will be started instead of the emulator...
CVE-2020-2078
Passwords are stored in plain text within the configuration of SICK Package Analytics software up to and including V04.1.1. An authorized attacker could access these stored plaintext credentials and gain access to the ftp service. Storing a password in plaintext allows attackers to easily gain...
CVE-2020-2076
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write fil...
CVE-2019-14753
SICK FX0-GPNT00000 and FX0-GENT00000 devices through 3.4.0 have a Buffer Overflow...
CVE-2019-10979
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password...
Vulnerabilities in SICK Flexi Compact
SICK has found two vulnerabilities that affect the SICK Flexi Compact. The vulnerabilities may affect the availability and confidentiality of the products. SICK is currently not aware of any public exploits...
SICK multiScan和SICK picoScan 安全漏洞
SICK multiScan and SICK picoScan are both products of the German company SICK. multiScan is an industrial safety scanner for area monitoring and hazardous area protection for automation equipment and machine safety applications. picoScan is a compact safety laser scanner for area monitoring and...
SICK FLX0-GPNT100和SICK FLX3-CPUC200 安全漏洞
The SICK FLX0-GPNT100 and SICK FLX3-CPUC200 are both products of SICK, Germany.The SICK FLX0-GPNT100 is a photoelectric sensor for precise object detection and localization in industrial automation.The SICK FLX3-CPUC200 is a high-performance photoelectric sensor controller designed for complex SI...