CVE-2023-5405

Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning...

5.9CVSS5.6AI score0.00404EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:46 p.m.29 views

CVE-2023-5405

Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning...

5.9CVSS5.8AI score0.00404EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:44 p.m.32 views

CVE-2023-5404

Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.6AI score0.00724EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:44 p.m.66 views

CVE-2023-5404

CVE-2023-5404 affects Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, and Safety Manager SC. Root cause: heap-based or out-of-bounds memory write triggered by processing a malformed message, potentially enabling remote code execution or service failure over the netwo...

8.1CVSS8.4AI score0.00724EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:43 p.m.15 views

CVE-2023-5403

Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS7.8AI score0.00724EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:43 p.m.31 views

CVE-2023-5403

Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.6AI score0.00724EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:42 p.m.33 views

CVE-2023-5401

Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.7AI score0.00746EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:42 p.m.16 views

CVE-2023-5401

Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.2AI score0.00746EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:42 p.m.87 views

CVE-2023-5401

CVE-2023-5401 affects Honeywell Experion products (PKS, LX, PlantCruise by Experion, Safety Manager, Safety Manager SC). A stack-based overflow can be triggered when the server receives a malformed message based on specified key values, potentially enabling remote code execution or a crash over t...

8.1CVSS8.1AI score0.00746EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:41 p.m.10 views

CVE-2023-5400

Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8AI score0.00746EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:41 p.m.78 views

CVE-2023-5400

The CVE-2023-5400 issue is a heap-based buffer overflow in Honeywell Experion family components (Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager/Safety Manager SC) that triggers when the server receives a malformed message based on specified key values. Root cause: heap overflo...

8.1CVSS8AI score0.00746EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:40 p.m.14 views

CVE-2023-5398

Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning...

5.9CVSS7.2AI score0.00443EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:40 p.m.17 views

CVE-2023-5398

Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning...

5.9CVSS6.2AI score0.00443EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:40 p.m.65 views

CVE-2023-5398

CVE-2023-5398 affects Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, and Safety Manager SC. The vulnerability arises from the server receiving a malformed message based on a list of IPs, which can trigger a heap-based/ memory corruption leading to a denial-of-servic...

5.9CVSS7.1AI score0.00443EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:38 p.m.24 views

CVE-2023-5397

Server receiving a malformed message to create a new connection could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.6AI score0.00773EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:38 p.m.74 views

CVE-2023-5397

CVE-2023-5397 affects Honeywell Experion PKS/LX/PlantCruise/Safety Manager and Safety Manager SC. The root cause is a server receiving a malformed message to establish a new connection, enabling remote code execution or causing a failure. Public documentation from multiple sources confirms an imp...

8.1CVSS7.7AI score0.00773EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/04/17 4:37 p.m.23 views

CVE-2023-5396

Server receiving a malformed message creates connection for a hostname that may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...

7.4CVSS8AI score0.00711EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:37 p.m.11 views

CVE-2023-5396

Server receiving a malformed message creates connection for a hostname that may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...

7.4CVSS7.9AI score0.00711EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/17 4:37 p.m.75 views

CVE-2023-5396

Summary: CVE-2023-5396 affects Honeywell Experion family (PKS, LX, PlantCruise, Safety Manager, Safety Manager SC). A malformed message can cause the server to open a connection for a hostname, potentially triggering a stack overflow and remote code execution. Root cause / impact: stack overflow ...

7.4CVSS7.8AI score0.00711EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/17 4:37 p.m.20 views

CVE-2023-5395

Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...

8.1CVSS8.2AI score0.00746EPSS
SaveExploits0References1