416 matches found
CVE-2017-9963
Summary: A cross-site request forgery vulnerability exists in the Secure Gateway component of Schneider Electric’s PowerSCADA Anywhere 1.0 (bundled with PowerSCADA Expert 8.1/8.2) and Citect Anywhere 1.0. The flaw enables multiple state-changing requests and requires some social engineering to lu...
PT-2018-8543
Name of the Vulnerable Software and Affected Versions PowerSCADA Anywhere version 1.0 PowerSCADA Expert versions 8.1 through 8.2 Citect Anywhere version 1.0 Description A cross-site request forgery issue exists in the Secure Gateway component, allowing for multiple state-changing requests. This...
CVE-2017-9963: Cross-Site Request Forgery (CSRF)
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack require...
SA163: OpenSSH Vulnerability October 2017
SUMMARY Symantec Network Protection products using affected versions of OpenSSH are susceptible to a security vulnerability. A remote attacker with read-only access to an SFTP server can create a large number of zero-length files and deplete the target's hard disk space. AFFECTED PRODUCTS The...
Symantec ASG and ProxySG Cross-Site Scripting Vulnerabilities
Symantec Advanced Secure Gateway ASG and ProxySG are both security gateway appliances from Symantec, Inc. management console is one of the management consoles. A cross-site scripting vulnerability exists in the management console in Symantec ASG and ProxySG. A remote attacker could exploit this...
Symantec ProxySG and Advanced Secure Gateway Information Disclosure Vulnerability
Symantec ProxySG and Advanced Secure Gateway ASG are both security gateway appliances from Symantec USA. An information disclosure vulnerability exists in Symantec ProxySG and ASG. A remote attacker could exploit the vulnerability to obtain sensitive information...
CVE-2016-10257
The Symantec Advanced Secure Gateway ASG 6.6, ASG 6.7 prior to 6.7.2.1, ProxySG 6.5 prior to 6.5.10.6, ProxySG 6.6, and ProxySG 6.7 prior to 6.7.2.1 management console is susceptible to a reflected XSS vulnerability. A remote attacker can use a crafted management console URL in a phishing attack ...
PT-2018-4649
Name of the Vulnerable Software and Affected Versions Symantec Advanced Secure Gateway ASG versions 6.6 through 6.7.2.1 Symantec ProxySG versions 6.5 through 6.5.10.6 Symantec ProxySG versions 6.6 through 6.7.2.1 Description The management console of the affected software is susceptible to a...
CVE-2016-10257: Improper Neutralization of Input During Web Page Generation
The Symantec Advanced Secure Gateway ASG 6.6, ASG 6.7 prior to 6.7.2.1, ProxySG 6.5 prior to 6.5.10.6, ProxySG 6.6, and ProxySG 6.7 prior to 6.7.2.1 management console is susceptible to a reflected XSS vulnerability. A remote attacker can use a crafted management console URL in a phishing attack ...
SA161: Local Information Disclosure Due to Meltdown and Spectre Attacks
SUMMARY Symantec Network Protection products, which run on an affected CPU chipset and execute arbitrary code from external sources, are susceptible to several information disclosure vulnerabilities aka Meltdown and Spectre attacks. A remote attacker, with the ability to execute arbitrary code...
CVE-2017-18001
Trustwave Secure Web Gateway SWG through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI...
SA157: OpenSSL Vulnerabilities 28-Aug-2017 and 2-Nov-2017
SUMMARY Symantec Network Protection products using affected versions of OpenSSL are susceptible to several vulnerabilities. A remote attacker can send a crafted X.509 certificate to cause unspecified impact. They can exploit, under certain circumstances, a computational flaw in the Montgomery...
Symantec ProxySG and Advanced Secure Gateway Remote Authorization Bypass Vulnerability
Symantec ProxySG and Advanced Secure Gateway ASG are both security gateway appliances from Symantec USA. A security vulnerability exists in Symantec ProxySG and ASG. A remote attacker could exploit the vulnerability to access the management console functionality...
CVE-2017-7969
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack require...
CVE-2017-7969
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack require...
CVE-2017-7970
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server...
Design/Logic Flaw
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server...
CVE-2017-7970: Undefined Security Weakness
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server...
CVE-2017-7969: Cross-Site Request Forgery (CSRF)
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack require...
CVE-2017-7970
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server...