Lucene search
+L

3541 matches found

CNVD
CNVD
added 2024/01/10 12:00 a.m.78 views

Siemens Spectrum Power 7 Critical Resource Privilege Assignment Error Vulnerability

Spectrum Power 7 provides the essential components of SCADA, communications and data modeling for control and monitoring systems. Application suites can be added to optimize network and generation management in all areas of energy management. Siemens Spectrum Power 7 suffers from a misassigned...

7.8CVSS7.3AI score0.00148EPSS
SaveExploits0References1
Packet Storm
Packet Storm
added 2024/01/09 12:00 a.m.299 views

AdvantechWeb/SCADA 9.1.5U SQL Injection

;; PostAuth SQLi in AdvantechWeb/SCADA 9.1.5U ;; ;; found: 28.12.2023 ;; ;; more: ;; https://code610.blogspot.com/2024/01/postauth-sqli-in-advantechwebscada-915u.html ;; POST /waconfig/api/odbc/getSystemLog HTTP/2 Host: 192.168.56.106 Cookie: serverLanguage=en;...

7.4AI score
SaveExploits0
zdt
zdt
added 2024/01/09 12:00 a.m.353 views

AdvantechWeb / SCADA 9.1.5U SQL Injection Vulnerability

AdvantechWeb/SCADA version 9.1.5U suffers from a post authentication remote SQL injection vulnerability. ;; PostAuth SQLi in AdvantechWeb/SCADA 9.1.5U ;; ;; found: 28.12.2023 ;; ;; more: ;; https://code610.blogspot.com/2024/01/postauth-sqli-in-advantechwebscada-915u.html ;; POST...

8.7AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2024/01/09 12:00 a.m.33 views

Rockwell FactoryTalk Services Platform < 6.20 Deserialization

The version of Rockwell FactoryTalk Services Platform installed on the remote Windows host is prior to 6.20. It is, therefore, affected by a vulnerability. - Factory Talk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCP/8082, which can insecurely deserialize untrusted...

10CVSS8.3AI score0.05497EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2023/12/27 12:00 a.m.14 views

PT-2023-8327 · Scada-Lts · Scada-Lts

Name of the Vulnerable Software and Affected Versions: Scada-LTS versions 2.7.5.2 build 4551883606 and before Description: The issue is related to insufficient access control in the Event Handlers function of the Scada-LTS mult-platform web solution for creating Scada systems. This allows remote...

8.8CVSS8.9AI score0.0127EPSS
SaveExploits1References8
BDU FSTEC
BDU FSTEC
added 2023/12/27 12:00 a.m.10 views

The vulnerability of the microprogrammed software of the ABB AC700F and AC900F controllers, as well as the ABB Freelance SCADA system, relates to the possibility of buffer overflows based on stacks. This allows a hacker to cause the controller to stop working.

The vulnerability of the microprogramming software for ABB AC700F and AC900F controllers, as well as the ABB Freelance SCADA system, relates to the possibility of buffer overflows based on stacks. Exploiting this vulnerability could allow a malicious actor, operating remotely, to cause the...

9CVSS7.4AI score0.00478EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2023/12/20 12:00 a.m.6 views

PT-2023-9241 · Unknown · Masterscada 4D

Name of the Vulnerable Software and Affected Versions: MasterSCADA 4D affected versions not specified Description: The issue is related to insufficient restriction of authentication attempts in the MasterSCADA 4D system. This can be exploited by a remote attacker to perform a brute force attack...

10CVSS7.1AI score
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2023/12/11 12:00 a.m.12 views

The vulnerability of the TRACE MODE SCADA system, related to unencrypted storage of user credentials, allows a hacker to replace one user’s password hash with another and gain access to the SCADA system.

The vulnerability of the TRACE MODE SCADA system is related to the unencrypted storage of user credentials. Exploiting this vulnerability could allow a perpetrator to replace the password hash for one user with that of another user and gain access to the SCADA system...

4.9CVSS5.5AI score
SaveExploits0Affected Software2
NVD
NVD
added 2023/12/08 12:15 a.m.26 views

CVE-2023-6061

Rejected reason: This CVE ID has been rejected/withdrawn by its CVE Numbering Authority Palo Alto Networks based on discussions with Mitsubishi Electronics Corporation's PSIRT...

SaveExploits0
Prion
Prion
added 2023/12/08 12:15 a.m.22 views

Design/Logic Flaw

Multiple components of Iconics SCADA Suite are prone to a Phantom DLL loading vulnerability. This issue arises from the applications improperly searching for and loading dynamic link libraries, potentially allowing an attacker to execute malicious code via a DLL with a matching name in an...

4.4CVSS7.5AI score
SaveExploits0References1Affected Software1
CVE
CVE
added 2023/12/07 11:21 p.m.64 views

CVE-2023-6061

CVE-2023-6061 is rejected/withdrawn by the CVE Numbering Authority; not an active vulnerability.

7.7AI score
SaveExploits0
Cvelist
Cvelist
added 2023/12/07 11:21 p.m.24 views

CVE-2023-6061

...

7.9AI score
SaveExploits0
Vulnrichment
Vulnrichment
added 2023/12/07 11:21 p.m.12 views

CVE-2023-6061

...

6.6AI score
SaveExploits0
CNNVD
CNNVD
added 2023/12/07 12:00 a.m.11 views

Number withdrawn

Iconics SCADA Suite is a PC-based monitoring and data acquisition software suite from Iconics USA. This CVE number has been withdrawn...

7.6AI score
SaveExploits0References3
The Hacker News
The Hacker News
added 2023/11/10 12:22 p.m.56 views

Russian Hackers Sandworm Cause Power Outage in Ukraine Amidst Missile Strikes

The notorious Russian hackers known as Sandworm targeted an electrical substation in Ukraine last year, causing a brief power outage in October 2022. The findings come from Google's Mandiant, which described the hack as a "multi-event cyber attack" leveraging a novel technique for impacting...

7.3AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2023/11/10 12:00 a.m.10 views

The vulnerability of the SCADA system PcVue, related to the disclosure of information through registration files, allows a intruder to disclose protected information.

The vulnerability of the SCADA system PcVue is related to the disclosure of information through registration files. Exploiting this vulnerability can allow a malicious actor to disclose the protected information...

6.8CVSS6.5AI score0.00329EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/10/31 12:00 a.m.21 views

The vulnerability of the EisBaer SCADA system, related to the storage of passwords in an unencrypted form, allows a intruder to expose the protected information and compromise the system.

The vulnerability of the EisBaer SCADA system is related to the storage of passwords in an unencrypted form. Exploiting this vulnerability can allow a perpetrator to disclose protected information and compromise the system...

7.1CVSS7.7AI score0.00425EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/10/31 12:00 a.m.8 views

The vulnerability of the EisBaer SCADA system, related to the use of dangerous methods or functions, allows a intruder to execute arbitrary codes.

The vulnerability of the EisBaer SCADA system is related to the use of dangerous methods or functions. Exploiting this vulnerability can allow a remote attacker to execute arbitrary code...

7.8CVSS8.1AI score0.00711EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/10/31 12:00 a.m.11 views

The vulnerability of the EisBaer SCADA system, which stems from the use of a strictly encrypted cryptographic key, allows attackers to gain unauthorized access to protected information.

The vulnerability of the EisBaer SCADA system is related to the use of a strictly encrypted cryptographic key. Exploiting this vulnerability could allow an intruder to gain unauthorized access to protected information...

7.1CVSS7.7AI score0.00425EPSS
SaveExploits0References4Affected Software1
OSV
OSV
added 2023/10/25 6:17 p.m.10 views

CVE-2023-42490

EisBaer Scada - CWE-200: Exposure of Sensitive Information to an Unauthorized Actor...

7.5CVSS5.8AI score0.00622EPSS
SaveExploits0References1
Rows per page
Query Builder