Lucene search
+L

3542 matches found

RedhatCVE
RedhatCVE
added 2025/05/22 10:29 p.m.12 views

CVE-2022-24310

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...

9.8CVSS7.9AI score0.02227EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:28 p.m.17 views

CVE-2022-24320

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...

5.9CVSS7AI score0.00544EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:12 p.m.12 views

CVE-2022-24317

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS6.5AI score0.01206EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:11 p.m.11 views

CVE-2022-24313

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...

9.8CVSS8.1AI score0.44559EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:12 p.m.15 views

CVE-2021-27436

WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing...

6.1CVSS6.7AI score0.0069EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 7:46 p.m.15 views

CVE-2021-32989

When a non-existent resource is requested, the LCDS LAquis SCADA application version 4.3.1.1011 and prior returns error messages which may allow reflected cross-site scripting...

9.3CVSS6.8AI score0.0243EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/05/22 6:46 p.m.12 views

CVE-2021-32954

Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system...

6.8CVSS6.8AI score0.02077EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 6:46 p.m.12 views

CVE-2021-32943

The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1...

9.8CVSS7.7AI score0.0187EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 6:41 p.m.13 views

CVE-2021-22824

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

7.5CVSS6.9AI score0.14241EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 6:37 p.m.9 views

CVE-2021-32956

Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage...

6.1CVSS6.7AI score0.00699EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:14 p.m.13 views

CVE-2020-25161

The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator...

8.8CVSS7.2AI score0.01509EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/05/22 4:07 p.m.11 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

7.5CVSS6.5AI score0.02493EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:07 p.m.14 views

CVE-2020-10622

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users...

7.8CVSS6.9AI score0.00809EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 3:56 p.m.9 views

CVE-2020-25188

An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability on the LAquis SCADA Versions prior to 4.3.1.870...

7.8CVSS7AI score0.01939EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/05/22 3:41 p.m.13 views

CVE-2020-6970

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

9.8CVSS7.4AI score0.02579EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 3:06 p.m.18 views

CVE-2020-28219

A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....

7.8CVSS6.9AI score0.00307EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/05/22 12:08 p.m.14 views

CVE-2012-4358

Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service invalid 0x00 write operation and daemon crash or possibly have unspecified other impact via a...

9.3CVSS7.8AI score0.0252EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/05/22 12:07 p.m.17 views

CVE-2012-4355

TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted negative integer after the opcode, triggering incorrect function-pointer processing that can lead to ...

9.3CVSS8.2AI score0.08186EPSS
SaveExploits3References1
RedhatCVE
RedhatCVE
added 2025/05/22 12:06 p.m.18 views

CVE-2012-4353

Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the TCPIPSBinOpenFileFP function,...

9.3CVSS8.2AI score0.4434EPSS
SaveExploits5References1
RedhatCVE
RedhatCVE
added 2025/05/22 11:15 a.m.14 views

CVE-2013-2794

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...

4.9CVSS6.8AI score0.00317EPSS
SaveExploits0References1
Rows per page