3516 matches found
Advantech WebAccess odeName2参数处理栈缓冲区溢出漏洞
CVE ID:CVE-2014-0766 Advantech WebAccess HMI/SCADA是一款HMI/SCADA软件。 Advantech WebAccess处理odeName2参数时不正确过滤用户输入,允许远程攻击者利用漏洞提交特殊参数触发基于栈的缓冲区溢出,可使应用程序崩溃或执行任意代码。 0 Advantech WebAccess 7.1 Advantech WebAccess 7.2版本已修复该漏洞,建议用户下载更新: http://webaccess.advantech.com/...
RuggedCom RuggedOS HTTP Traffic Handling Remote DoS
Binary data scadaruggedoshttp41.nbin...
RuggedCom RuggedOS SNMP Protocol Unspecified DoS
Binary data scadaruggedoscve20141966.nbin...
Advantech WebAccess Multiple BWOCXRUN.OCX ActiveX Vulnerabilities
Binary data scadaadvantechbwocxrun1.nbin...
Cyber Intelligence Asia 2014: CERTs and Industrial Security
In March I spoke at Cyber Intelligence Asia 2014, where CERTs from most Asians countries were presented. The fact is that only a few CERTs are now dealing in some way with industrial security, ICS and SCADA matters. One of the best of those is CERT of Japan, which is doing a great job here, and...
Is It Time for Certified ICS Security Specialists?
The information security field is full of certifications – CompTIA, GIAC, CHE, ISC2 CISSP, CISM, with a vast number of areas and directions within these families. In the industrial space, the most “unsecured” enterprise sector compared to well-established information security practice in most...
SCADA Vulnerabilities Identified in Power, Petrochemical Plants
More than 7,600 different power, chemical and petrochemical plants may still be vulnerable to a handful of SCADA vulnerabilities made public this week. A researcher at Rapid 7, the Boston-based firm responsible for the popular pen testing software Metasploit, and an independent security researche...
CVE-2014-0779
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2014-0779 Schneider Electric StruxureWare SCADA Expert ClearSCADA Improper Restriction of Operations within the Bounds of a Memory Buffer
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2014-0779
The CVE-2014-0779 issue affects the Kepware KepServerEX V4 PLC Driver in the ServerMain.exe component of Schneider Electric StruxureWare SCADA Expert ClearSCADA, impacting multiple release/build combos listed in the NVD entry (2010 R2, 2010 R2.1, 2010 R3, 2010 R3.1, 2013 R1, 2013 R1.1, 2013 R1.1a...
COPA-DATA Improper Input Validation
OVERVIEW Automation software company Ing. Punzenberger COPA-DATA GmbH reported an improper input validation vulnerability affecting the DNP3 driver in the zenon SCADA software. The vulnerability was found based on the DNP3 research conducted by Adam Crain of Automatak and Chris Sistrunk of...
Schneider Electric Patches SCADA, ICS Security Vulnerabilities
The Industrial Control Systems Cyber Emergency Response Team ICS-CERT last week issued advisories warning of serious vulnerabilities in Schneider Electric SCADA gear. Schneider Electric is a supplier of energy management control products that are used in a number of critical industries in North...
Triangle MicroWorks Uncontrolled Resource Consumption
OVERVIEW Adam Crain of Automatak and Chris Sistrunk of Mandiant have identified an uncontrolled resource consumption vulnerability in Triangle MicroWorks products and third-party components. Triangle MicroWorks has produced an update that mitigates this vulnerability. This vulnerability could be...
Schneider Electric SCADA多个产品异常处理拒绝服务漏洞
CVE ID:CVE-2013-2824 施耐德电气为100多个国家的能源及基础设施、工业、数据中心及网络、楼宇和住宅市场提供整体解决方案。其中多个产品使用的SESU工具用于更新windows PC系统上的软件。 Schneider Electric多个产品服务器存在拒绝服务攻击,允许远程攻击者利用漏洞发送特制的报文,可使进程停止响应,造成拒绝服务攻击。 0 Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40 Schneider Electric Vijeo Citect 7.20 - 7.30SP1...
CVE-2013-2824
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...
Design/Logic Flaw
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...
CVE-2013-2824
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...
CVE-2013-2824
CVE-2013-2824 affects Schneider Electric StruxureWare SCADA Expert Vijeo Citect (v7.40), Vijeo Citect (v7.20–7.30SP1), CitectSCADA (v7.20–7.30SP1), StruxureWare PowerSCADA Expert (v7.30–7.30SR1), and PowerLogic SCADA (v7.20–7.20SR1). The issue is an exception-handling flaw that allows remote atta...