CVE-2017-16721
A Cross-site Scripting issue was discovered in Geovap Reliance SCADA Version 4.7.3 Update 2 and prior. This vulnerability could allow an unauthenticated attacker to inject arbitrary code...
CVE-2017-16721
A Cross-site Scripting issue was discovered in Geovap Reliance SCADA Version 4.7.3 Update 2 and prior. This vulnerability could allow an unauthenticated attacker to inject arbitrary code...
CVE-2017-16721
Geovap Reliance SCADA is affected by CVE-2017-16721, an XSS vulnerability in versions 4.7.3 Update 2 and prior. An unauthenticated attacker could inject arbitrary code via a crafted URL, potentially enabling read/write access in the affected system. ICS-CERT reports a fixed version 4.7.3 Update 3...
Geovap Reliance SCADA Cross-Site Scripting Vulnerability
Reliance is a professional SCADA/HMI system designed for the visualization and control of industrial processes as well as building and home automation. A cross-site scripting vulnerability exists in Geovap Reliance SCADA that allows an unauthenticated attacker to inject arbitrary code...
GEOVAP Reliance SCADA
CVSS v3 6.1 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GEOVAP Equipment: Reliance SCADA Vulnerability: Cross-site Scripting AFFECTED PRODUCTS The following versions of Reliance SCADA, a software management platform, are affected: Reliance SCADA Version 4.7.3 Update 2 and...
Siemens Update Patches SIMATIC PCS 7 Bug in Some Versions
Siemens has made an update available for some of its SIMATIC PCS 7 distributed control systems that are impacted by a remotely exploitable input validation vulnerability. Siemens said version 8.2 and V8.1 prior to 8.1 SP1 with WinCC v7.3 Update 13 are affected. “Successful exploitation of this...
Progea Movicon 11.5.1181 Search Path Issues Vulnerability
Progea Movicon versions 11.5.1181 and below suffer from search path related vulnerabilities. Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element Advisory URL...
SpiderControl SCADA Web Server 2.02.0007 Improper Privilege Management Vulnerability
SpiderControl SCADA Web Server versions 2.02.0007 and below suffer from an improper privilege management vulnerability. Vendor: SpiderControl Equipment: SCADA Web Server Vulnerability: Improper Privilege Management Advisory URL...
Trihedral Engineering Limited VTScada DLL Hijacking Vulnerability
VTScada is a SCADA system from Trihedral Engineering, Canada, based on a Windows platform with a Web interface option. Trihedral Engineering Limited VTScada suffers from a DLL hijacking vulnerability that could allow an attacker to cause the program to execute a specially crafted malicious dll fi...
Progea Movicon 11.5.1181 Search Path Issues
Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element Advisory URL https://ipositivesecurity.com/2017/10/28/ics-progea-movicon-scadahmi-vulnerabilities/ ICS-CERT Advisory https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01...
SpiderControl SCADA Web Server 2.02.0007 Improper Privilege Management
Vendor: SpiderControl Equipment: SCADA Web Server Vulnerability: Improper Privilege Management Advisory URL https://ipositivesecurity.com/2017/10/28/ics-spidercontrol-scada-web-server-improper-privilege-management-vulnerability/ ICS-CERT Advisory...
Critical Infrastructure and Cyber Security
Before the recent natural disasters, I could describe to you how we as a community might recover after a cyberattack to our critical infrastructure, but it would be hard to imagine. Some may argue that it would be too extreme of a scenario to consider and that we would never get to the point wher...
Progea Movicon SCADA/HMI
CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element AFFECTED PRODUCTS The following versions of Movicon HMI, an HMI software platform, are affected:...
CVE-2017-12728
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the...
CVE-2017-12728
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the...
Input validation
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the...
GE CIMPLICITY
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow AFFECTED PRODUCTS The following versions of CIMPLICITY, an HMI/SCADA management platform, are affected: CIMPLICITY Versions 9.0 and prior. IMPACT...
GE CIMPLICITY (Update A)
CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow UPDATED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-278-01 GE CIMPLICITY that was published October 5,...
The vulnerability of the GE Proficy HMI/SCADA iFIX monitoring tool for technological operations, the client-server application for data processing and control of technological operations (Proficy HMI/SCADA CIMPLICITY), and the Proficy Historian repository lies in the insufficient security of account protection, allowing attackers to obtain user passwords.
The vulnerability of the GE Proficy HMI/SCADA iFIX control system, the client-server application for data processing and control operations, as well as the Proficy HMI/SCADA CIMPLICITY control system and the Proficy Historian repository, is related to insufficiently secure account protection...
CVE-2017-12728
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the...