Lucene search
+L

3519 matches found

CNVD
CNVD
added 2019/01/17 12:00 a.m.12 views

LCDS LAquis SCADA Out-of-Bounds Write Vulnerability

LCDS LAquis SCADA is a SCADA Data Acquisition and Supervisory Control system from the Brazilian company LCDS. The system is mainly used for data acquisition and process control of equipment with communication technology. An out-of-bounds write vulnerability exists in LCDS LAquis SCADA version...

7.8CVSS7.1AI score0.01054EPSS
SaveExploits0References1
Prion
Prion
added 2018/12/24 4:29 p.m.16 views

Design/Logic Flaw

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

4.6CVSS8.4AI score0.00322EPSS
SaveExploits0References1Affected Software4
NVD
NVD
added 2018/12/24 4:29 p.m.20 views

CVE-2018-7793

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

8.7CVSS8.6AI score0.00322EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/12/24 4:00 p.m.26 views

CVE-2018-7793

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

8.6AI score0.00322EPSS
SaveExploits0References1
CVE
CVE
added 2018/12/24 4:00 p.m.50 views

CVE-2018-7793

A credential management vulnerability exists in FoxView HMI SCADA across Foxboro DCS, Foxboro Evo, and IA Series. Affects versions prior to CCS 9.4 (DCS Core Services) and FoxView 10.5. The issue could allow unauthorized disclosure, modification, or disruption in service when the password is modi...

8.7CVSS8.4AI score0.00322EPSS
SaveExploits0References1Affected Software4
NVD
NVD
added 2018/12/19 6:29 p.m.48 views

CVE-2018-18999

WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack...

7.5CVSS7.3AI score0.02309EPSS
SaveExploits0References3
Prion
Prion
added 2018/12/19 6:29 p.m.16 views

Buffer overflow

WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack...

7.5CVSS7.2AI score0.02309EPSS
SaveExploits0References3Affected Software1
OSV
OSV
added 2018/12/19 6:29 p.m.13 views

CVE-2018-18999

WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack...

7.3CVSS6AI score0.02309EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2018/12/19 6:00 p.m.36 views

CVE-2018-18999

WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack...

7.3AI score0.02309EPSS
SaveExploits0References3
CVE
CVE
added 2018/12/19 6:00 p.m.73 views

CVE-2018-18999

CVE-2018-18999 affects Advantech WebAccess/SCADA (Version 8.3.2 on Windows 2008 R2 SP1). Root cause: a stack-based buffer overflow due to lack of boundary checks when copying user-supplied data into BwPAlarm.dll, enabling remote unauthenticated exploitation via RPC requests. Impact is a potential...

7.5CVSS7.3AI score0.02309EPSS
SaveExploits0References3Affected Software1
ICS
ICS
added 2018/12/18 12:00 a.m.59 views

Advantech WebAccess/SCADA

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: WebAccess/SCADA Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a stack buffer overflow condition. 3...

7.5CVSS7.6AI score0.02309EPSS
SaveExploits0References5
OSV
OSV
added 2018/12/17 10:29 p.m.14 views

CVE-2018-7797

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert formerly Power Manager - EcoStruxure Power Monitoring Expert PME v8.2 all editions, EcoStruxure Energy Expert 1.3 formerly Power Manager, EcoStruxure Power SCADA Operation PSO 8.2 Advanced Reports and Dashboards...

6.1CVSS5.8AI score0.00755EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/12/17 10:00 p.m.36 views

CVE-2018-7797

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert formerly Power Manager - EcoStruxure Power Monitoring Expert PME v8.2 all editions, EcoStruxure Energy Expert 1.3 formerly Power Manager, EcoStruxure Power SCADA Operation PSO 8.2 Advanced Reports and Dashboards...

6.2AI score0.00755EPSS
SaveExploits0References2
Trend Micro Simply Security
Trend Micro Simply Security
added 2018/12/11 1:05 p.m.43 views

2019 Security Predictions Report Released

What Makes For Really Good Security Predictions Each year Trend Micro releases its annual Security Predictions Report. Good security predictions are very difficult to develop, and companies and consumers need to be selective about the security advice they take. What makes a good security...

6.9AI score
SaveExploits0
CNVD
CNVD
added 2018/12/05 12:00 a.m.13 views

iniNet SpiderControl SCADA WebServer Cross-Site Scripting Vulnerability

The iniNet SpiderControl SCADA WebServer is a SCADA system server from iniNet Solutions, Switzerland. A cross-site scripting vulnerability exists in iniNet SpiderControl SCADA WebServer versions prior to 2.03.0001. A remote attacker can exploit this vulnerability by sending a specially crafted UR...

6.1CVSS6.1AI score0.00852EPSS
SaveExploits0References1
OSV
OSV
added 2018/12/04 9:29 p.m.12 views

CVE-2018-18991

Reflected cross-site scripting non-persistent in SCADA WebServer Versions prior to 2.03.0001 could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser...

6.1CVSS5.7AI score0.00852EPSS
SaveExploits0References2
Prion
Prion
added 2018/12/04 9:29 p.m.21 views

Cross site scripting

Reflected cross-site scripting non-persistent in SCADA WebServer Versions prior to 2.03.0001 could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser...

4.3CVSS5.9AI score0.00852EPSS
SaveExploits0References2Affected Software1
NVD
NVD
added 2018/12/04 9:29 p.m.33 views

CVE-2018-18991

Reflected cross-site scripting non-persistent in SCADA WebServer Versions prior to 2.03.0001 could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser...

6.1CVSS6AI score0.00852EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/12/04 9:00 p.m.37 views

CVE-2018-18991

Reflected cross-site scripting non-persistent in SCADA WebServer Versions prior to 2.03.0001 could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser...

6AI score0.00852EPSS
SaveExploits0References2
CVE
CVE
added 2018/12/04 9:00 p.m.54 views

CVE-2018-18991

SpiderControl SCADA WebServer (versions prior to 2.03.0001) is affected by CVE-2018-18991: a reflected cross-site scripting (non-persistent) flaw caused by improper input neutralization during web page generation. An attacker can craft a URL to execute JavaScript in a victim’s browser. Mitigation...

6.1CVSS5.9AI score0.00852EPSS
SaveExploits0References2Affected Software1
Rows per page