3519 matches found
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
Stack overflow
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
Design/Logic Flaw
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10611
CVE-2020-10611 is a real, externally exploitable type-confusion vulnerability in Triangle MicroWorks SCADA Data Gateway (DNP3 Data Sets). The Red Hat and NVD entries confirm it affects versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122, enabling remote code execution with no authentication required...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...
CVE-2020-10615
CVE-2020-10615 affects Triangle MicroWorks SCADA Data Gateway, specifically versions 3.02.0697–4.0.122 and 2.41.0213–4.0.122. The root cause is improper validation of the length of user-supplied data prior to copying into a fixed-length stack-based buffer, causing a stack-based buffer overflow. T...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
Privilege escalation
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
CVE-2020-6992
GE Digital CIMPLICITY HMI/SCADA vulnerability CVE-2020-6992 affects CIMPLICITY v10.0 and earlier. It is a local privilege escalation (CWE-269) that requires an authenticated session to modify the system and arbitrarily execute code. Affected component: CIMPLICITY HMI/SCADA software; root cause is...
Triangle MicroWorks SCADA Data Gateway Buffer Overflow Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. A security vulnerability exists in Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 and 2.41.0213 through 4.0.122, which arises from the program failing to properly...
Triangle MicroWorks SCADA Data Gateway
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Triangle MicroWorks Equipment : SCADA Data Gateway Vulnerabilities : Stacked-based Buffer Overflow, Out-of-Bounds Read, Type Confusion 2. RISK EVALUATION These vulnerabilities allow remote...
The vulnerability of the zenone32.exe editor in the COPA-DATA SCADA system allows a intruder to execute arbitrary code.
The vulnerability of the zenone32.exe editor in the COPA-DATA SCADA system is related to an uncontrolled element in the search process. Exploiting this vulnerability could allow a perpetrator to execute arbitrary code...
Advantech WebAccess Buffer Overflow Vulnerability (CNVD-2020-19926)
Advantech WebAccess is a set of HMI/SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphic display and real-time data control, and provides remote control and management of automation equipment. A buffer overflow vulnerability exists in...