Lucene search
+L

3881 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/04/09 12:00 a.m.•1 views

CVE-2026-34185: Improper Neutralization of Special Elements used in an SQL Command

AlanWeb SCADA is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database. This issue was fixed in AlanWeb SCADA version 9.8.5...

8.8CVSS6AI score0.00466EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2026/03/09 12:00 a.m.•6 views

CVE-2025-70973

ScadaBR 1.12.4 is vulnerable to Session Fixation. The application assigns a JSESSIONID session cookie to unauthenticated users and does not regenerate the session identifier after successful authentication. As a result, a session created prior to login becomes authenticated once the victim logs i...

5.8AI score0.002EPSS
SaveExploits1References2
Packet Storm News
Packet Storm News
•added 2026/03/01 12:00 a.m.•11 views

Power Network SCADA Quantum Communications: A Comparison of BB84, B92, E91, and SGS04 Quantum Key Distribution Protocols

The current state, emerging trends, and practical challenges of optical fiber-based power network SCADA quantum communication must be addressed to fully utilise the technological platform's potential in real-world power system SCADA communications involving massive volumes of real-time data, as...

5.9AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
•added 2026/02/20 12:00 a.m.•14 views

The vulnerability of the multi-platform web solution for creating Scada systems, Scada-LTS, is related to insufficient verification of the authenticity of executed requests. This allows attackers to bypass security restrictions and carry out CSRF attacks.

The vulnerability of the multi-platform web solution for creating Scada systems is related to insufficient verification of the authenticity of executed requests. Exploiting this vulnerability allows a malicious actor to bypass security restrictions and perform CSRF attacks...

10CVSS5.8AI score0.00264EPSS
SaveExploits1References6Affected Software1
Cvelist
Cvelist
•added 2026/02/18 9:54 p.m.•42 views

CVE-2019-25349 scadaApp for iOS 1.1.4.0 - 'Servername' Denial of Service

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in the Servername field. Attackers can paste a 257-character buffer during login to trigger an application crash on iOS devices...

7.5CVSS0.00248EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2026/02/18 12:00 a.m.•13 views

The vulnerability of the SCADA system’s web server FAST/TOOLS allows a perpetrator to carry out an MITM attack.

The vulnerability of the FAST/TOOLS SCADA system’s web server is related to improper security checks for standard elements. Exploiting this vulnerability could allow a malicious actor to carry out an MITM attack...

8.5CVSS5.8AI score0.00328EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2026/02/18 12:00 a.m.•11 views

The vulnerability of the SCADA system FAST/TOOLS, related to the manipulation of cross-site requests, allows a hacker to perform a CSRF attack.

The vulnerability of the SCADA system FAST/TOOLS is related to the manipulation of inter-site requests. Exploiting this vulnerability allows a malicious actor to perform a CSRF attack remotely...

5.3CVSS5.7AI score0.001EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/02/18 12:00 a.m.•16 views

PT-2026-20524

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in the Servername field. Attackers can paste a 257-character buffer during login to trigger an application crash on iOS devices...

7.5CVSS5.8AI score0.00248EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2026/02/18 12:00 a.m.•11 views

The vulnerability of the SCADA system’s web server FAST/TOOLS allows a intruder to disclose protected information.

The vulnerability of the FAST/TOOLS SCADA system’s web server is related to the use of cryptographic algorithms that contain vulnerabilities. Exploiting this vulnerability could allow a malicious actor to disclose the protected information...

7.5CVSS5.7AI score0.00161EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2026/02/18 12:00 a.m.•12 views

The vulnerability of the SCADA system’s web server FAST/TOOLS allows a intruder to disclose protected information.

The vulnerability of the FAST/TOOLS SCADA system’s web server is related to the use of cryptographic algorithms that contain vulnerabilities. Exploiting this vulnerability could allow a malicious actor to disclose the protected information...

8.5CVSS5.7AI score0.00176EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2026/02/17 12:00 a.m.•12 views

The vulnerability of the SCADA system’s web server, Yokogawa FAST/TOOLS, allows a hacker to bypass existing security restrictions.

The vulnerability of the SCADA system’s web server, Yokogawa FAST/TOOLS, is related to deficiencies in authentication procedures. Exploiting this vulnerability could allow attackers to circumvent existing security restrictions remotely...

5.3CVSS5.7AI score0.0032EPSS
SaveExploits0References2
GithubExploit
GithubExploit
•added 2026/02/12 3:02 a.m.•218 views

Exploit for Path Traversal in Laquisscada Scada

LAquis SCADA Arbitrary File Write 👨‍💻 Author Mohammed...

7.8CVSS5.7AI score0.01268EPSS
SaveExploits1
BDU FSTEC
BDU FSTEC
•added 2026/02/11 12:00 a.m.•19 views

The vulnerability of the KLogic SCADA system’s virtual controller “KASKAD” allows a intruder to increase their privileges and delete arbitrary files.

The vulnerability of the KLogic SCADA system “KASKAD” virtual controller is related to incorrect external control of the file name or file path. Exploiting this vulnerability can allow a malicious actor to increase their privileges and delete arbitrary files...

9.9CVSS5.9AI score
SaveExploits0References1Affected Software1
BDU FSTEC
BDU FSTEC
•added 2026/02/11 12:00 a.m.•32 views

The vulnerability of the KLogic SCADA system’s virtual controller “KASCAD” allows a intruder to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the KLogic SCADA system “KASKAD”’s virtual controller is related to bypassing authentication by using an alternative path or channel. Exploiting this vulnerability allows a malicious actor to compromise the confidentiality, integrity, and accessibility of the protected...

10CVSS5.8AI score
SaveExploits0References1Affected Software1
BDU FSTEC
BDU FSTEC
•added 2026/02/11 12:00 a.m.•32 views

The vulnerability of the KLogic SCADA system’s virtual controller “KASCAD” allows a intruder to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the KLogic SCADA system “KASKAD”’s virtual controller is related to the use of a password hash instead of the actual password for authentication. Exploiting this vulnerability allows an intruder to compromise the confidentiality, integrity, and accessibility of the protected...

10CVSS5.8AI score
SaveExploits0References1Affected Software1
attackerkb
attackerkb
•added 2026/02/09 10:24 p.m.•12 views

CVE-2026-25951

FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. Prior to 1.2.11, there is a flaw in the path sanitization logic allows an authenticated attacker with administrative privileges to bypass directory traversal protections. By using nested traversal sequences e.g., ....//, an...

8.6CVSS5.9AI score0.01765EPSS
SaveExploits0References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/02/09 12:00 a.m.•2 views

CVE-2026-25939: Missing Authorization

FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. From 1.2.8 through version 1.2.10, an authorization bypass vulnerability in the FUXA allows an unauthenticated, remote attacker to create and modify arbitrary schedulers, exposing connected ICS/SCADA environments to follow-on...

9.3CVSS6AI score0.00857EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2026/02/07 7:30 p.m.•12 views

CVE-2026-25752

FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. An authorization bypass vulnerability in FUXA allows an unauthenticated, remote attacker to modify device tags via WebSockets. Exploitation allows an unauthenticated, remote attacker to bypass role-based access controls and...

9.3CVSS5.5AI score0.00675EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2026/02/06 7:05 p.m.•14 views

CVE-2026-25752

FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. An authorization bypass vulnerability in FUXA allows an unauthenticated, remote attacker to modify device tags via WebSockets. Exploitation allows an unauthenticated, remote attacker to bypass role-based access controls and...

9.3CVSS5.5AI score0.00675EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/02/06 12:00 a.m.•2 views

CVE-2026-25752: Missing Authorization

FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. An authorization bypass vulnerability in FUXA allows an unauthenticated, remote attacker to modify device tags via WebSockets. Exploitation allows an unauthenticated, remote attacker to bypass role-based access controls and...

9.3CVSS6AI score0.00675EPSS
SaveExploits0References1
Rows per page
Query Builder