3519 matches found
Code injection
A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process FHSvrService.exe to exit...
CVE-2022-21155 Fernhill SCADA Uncontrolled Resource Consumption
A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process FHSvrService.exe to exit...
CVE-2022-21155
Fernhill SCADA Server (Fernhill SCADA Server Version 3.77 and earlier) is affected by CVE-2022-21155. A specially crafted packet can trigger an exception that causes the server process (FHSvrService.exe) to exit, resulting in a denial-of-service condition. CVSS v3.1 base score is 7.5 (AV:N/AC:L/P...
CVE-2022-21155 Fernhill SCADA Uncontrolled Resource Consumption
A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process FHSvrService.exe to exit...
The vulnerability of the client-server data processing and technical operations control application Proficy HMI/SCADA CIMPLICITY, related to the transmission of data in an open format, allows attackers to perform spoofing attacks.
The vulnerability of the client-server data processing and technical operations control application Proficy HMI/SCADA CIMPLICITY lies in the transmission of data in an open manner. Exploiting this vulnerability can allow attackers to carry out spoofing attacks...
The vulnerability of the interactive graphical SCADA system, Interactive Graphical SCADA System (IGSS), arises due to an incorrect restriction on the name of the path to the restricted access catalog. This allows a intruder to execute arbitrary code.
The vulnerability of the Interactive Graphical SCADA System IGSS exists due to an incorrect restriction on the name of the path to the restricted access catalog. Exploiting this vulnerability could allow a malicious actor, operating remotely, to execute arbitrary code using a specially created...
CISA Warns of High-Severity Flaws in Schneider and GE Digital's SCADA Software
The U.S. Cybersecurity and Infrastructure Security Agency CISA last week published an industrial control system ICS advisory related to multiple vulnerabilities impacting Schneider Electric's Easergy medium voltage protection relays. "Successful exploitation of these vulnerabilities may disclose...
CVE-2022-25359
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files...
CVE-2022-25359
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files...
Code injection
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files...
CVE-2022-25359
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files...
CVE-2022-25359
CVE-2022-25359 affects Industrial Control Links ScadaFlex II SCADA Controllers SC-1/SC-2. According to ICS/CISA data, unauthenticated remote attackers can overwrite, delete, or create files via external control of file name or path (CWE-73). Affected SW versions include 1.03.07 (build 317) and ol...
PT-2022-6571 · Icl · Icl Scadaflex Ii Scada Controller Sc-1 +1
Name of the Vulnerable Software and Affected Versions: ICL ScadaFlex II SCADA Controller SC-1 and SC-2 version 1.03.07 Description: The issue is related to the lack of an authentication procedure, allowing unauthenticated remote attackers to overwrite, delete, or create files on the device. This...
ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 - Remote File CRUD
Exploit Title: CL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Exploit Author: LiquidWorm !/usr/bin/env python3 -- coding: utf-8 -- ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Vendor: Industrial Control Links, Inc. Product web page:...
Industrial Control Links Icl ScadaFlex II Scada Controllers 访问控制错误漏洞
Industrial Control Links Icl ScadaFlex II Scada Controllers is a set of Web Scada controllers from Industrial Control Links, Inc. It is designed to provide a complete Scada system at the lowest possible cost. An Access Control Error vulnerability exists in ICL ScadaFlex II SCADA Controllers...
ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File Modification
!/usr/bin/env python3 -- coding: utf-8 -- ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Vendor: Industrial Control Links, Inc. Product web page: http://www.iclinks.com Product datasheet:...
ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD
Summary Scadaflex II controllers are 100% web based for both configuration and user interface. No applications are required other than any standard web browser. They are easily supported by remote access over the Internet or a cellular link. Scadaflex II controllers support industry standard wire...
ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File Modification Exploit
ICL ScadaFlex II SCADA Controllers SC-1/SC-2 version 1.03.07 is vulnerable to unauthenticated file write/overwrite and deletion. This allows an attacker to execute critical file CRUD operations on the device that can potentially allow system access and impact availability. !/usr/bin/env python3 -...
Schneider Electric Interactive Graphical Scada System Integer Overflow Vulnerability
The Schneider Electric Interactive Graphical Scada System Igss is a Scada system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical Scada System has an integer overflow vulnerability that can be exploited by an attacke...
Schneider Electric Interactive Graphical SCADA System Initialization Error Vulnerability
Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An initialization error vulnerability exists in the Schneider Electric Interactive Graphical...