CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24310
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24313
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...
CVE-2019-6827
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System IGSS, Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated...
The vulnerability of the multi-platform SCADA system KROON-TM, related to the use of a rigidly encrypted cryptographic key for the SSL certificate, allows a intruder to gain unauthorized access to protected information.
The vulnerability of the multi-platform SCADA system KROON-TM is related to the use of a rigidly encrypted cryptographic key for the SSL certificate. Exploiting this vulnerability could allow an attacker, operating remotely, to gain unauthorized access to protected information...
The vulnerability of the Vnet/IP SCADA system of Yokogawa CENTUM VP allows a intruder to execute arbitrary code and trigger a maintenance failure.
The vulnerability of the Vnet/IP SCADA system of Yokogawa CENTUM VP is related to a countable loss of significance. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands and cause service failures by sending specially crafted packets...
PT-2024-41439 · Ооо 'Теконавтоматика' · Scada-Система 'Текон'
Уязвимость SCADA-системы «Текон», связанная с передачей учетных данных в незашифрованном виде. Эксплуатация уязвимости, может позволить нарушителю, действующему удаленно выполнить атаку «человек посередине» MITM...
mySCADA myPRO Manager Directory Traversal Vulnerability
mySCADA myPRO is a professional HMI/SCADA system designed primarily for the visualization and control of industrial processes. A directory traversal vulnerability exists in mySCADA myPRO Manager, which can be exploited by an attacker to submit a special request to view the contents of a system fi...
Scada-LTS 跨站脚本漏洞
Scada-LTS is an open source, web-based, multi-platform solution from Scada-LTS Open Source. A cross-site scripting vulnerability exists in Scada-LTS version 2.7.8, which stems from unknown functionality in the file /Scada-LTS/app.shtm/alarms/Scada that results in cross-site scripting...
The vulnerability of the SCADA system MasterSCADA 4D arises from incorrect restrictions on the path to the restricted access catalog. This allows intruders to read and write arbitrary files and execute arbitrary commands.
The vulnerability of the SCADA system MasterSCADA 4D is related to an incorrect restriction on the path to the restricted access catalog. Exploiting this vulnerability allows a malicious actor to read and write arbitrary files, as well as execute arbitrary commands...
Siemens SIMATIC WinCC Information Disclosure Vulnerability (CNVD-2024-32687)
Siemens SIMATIC PCS 7 is a process control system from Siemens, Germany.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system.SIMATIC WinCC Runtime Professional is a runtime platform for operator visualization, machine and device control and monitoring. equipment control and...
CVE-2024-2882 Missing Authorization in SDG Technologies PnPSCADA
SDG Technologies PnPSCADA allows a remote attacker to attach various entities without requiring system authentication. This breach could potentially lead to unauthorized control, data manipulation, and access to sensitive information within the SCADA system...
CVE-2024-2882
CVE-2024-2882 affects SDG Technologies PnPSCADA (web-based SCADA HMI). Connected sources (CISA ICS advisory ICSA-24-179-02, Red Hat CVE page, NVD/NIST entries) confirm a missing authorization flaw (CWE-862) that allows a remote attacker to attach various entities without authenticating, potential...
Siemens (China) Ltd. WinCC suffers from Denial of Service Vulnerability (CNVD-C-2024-309044)
WinCC is a SCADA system for a wide range of industries that allows you to access devices, extract smart data, analyze data and report on it from your mobile. A denial of service vulnerability exists in Siemens China Ltd WinCC, which can be exploited by attackers to cause a denial of service...
LCDS LAquis SCADA 路径遍历漏洞
LCDS LAquis SCADA is a SCADA Data Acquisition and Supervisory Control system from the Brazilian company LCDS. The system is mainly used for data acquisition and process control of devices that have communication technology. A path traversal vulnerability exists in LCDS LAquis SCADA version 4.7.1....