2320 matches found
CVE-2015-1601
CVE-2015-1601 affects Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1. The root cause is a man-in-the-middle vulnerability in network communications (Port 102/TCP) that can allow attackers to intercept or modify transmitted data, potentially exposing sensitive information or enab...
CVE-2015-1602
Siemens SIMATIC STEP 7 (TIA Portal) v12 and v13 prior to SP1 Upd1 are affected by CVE-2015-1602, which involves storing cleartext passwords in project files, enabling local attackers to reconstruct protection-level and web-server passwords from read files. The issue comprises two related weakness...
CVE-2015-1601: Undefined Security Weakness
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
PT-2015-5381
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC STEP 7 TIA Portal versions 12 and 13 before 13 SP1 Upd1 Description The issue allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. Recommendations For versions 1...
CVE-2015-1602: Exposure of Sensitive Information to an Unauthorized Actor
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
PT-2015-5382
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC STEP 7 TIA Portal versions 12 and 13 before 13 SP1 Upd1 Description The issue improperly stores password data within project files. This makes it easier for local users to determine cleartext protection-level passwords or...
KLA10534 Sensitive information obtain vulnerabilities in Siemens SIMATIC STEP
Improper password store and other uncnown vulnerability were found in SIMATIC STEP 7. By exploiting these vulnerabilities malicious users can obtain sensitive information. These vulnerabilities can be exploited remotely via an unknown vectors. Original advisories Siemens advisory Exploitation...
Various Siemens products have search path vulnerabilities
Siemens SIMATIC ProSave; SIMATIC CFC 8 SP4 upd9 8.1 upd1; SIMATIC STEP 7 5.5 SP1 Hf2 5.5 SP2 5.5 SP4 HF4 HF7 sp35.5; SIMOTION Scout 4.4 Starter 4.4 HF3 are all Siemens Siemens Germany company in Germany. A search path vulnerability exists in several Siemens products, allowing local users to gain...
Siemens SIMATIC STEP 7 (TIA Portal) Detection
Binary data scadaappsiemenstiastep7detect.nbin...
PT-2015-5375
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC ProSave versions prior to 13 SP1 Siemens SIMATIC CFC versions prior to 8.0 SP4 Upd9 and 8.1 Upd1 Siemens SIMATIC STEP 7 versions prior to 5.5 SP1 HF2, 5.5 SP2 HF7, 5.5 SP3, and 5.5 SP4 HF4 Siemens SIMOTION Scout versions prior ...
CVE-2015-1594: Undefined Security Weakness
Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to ga...
Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836)
Binary data scadasiemenstiamultiplevulnerabilitiesSSA-315836.nbin...
Siemens SIMATIC STEP 7 TIA Portal Man-in-the-Middle Attack Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A man-in-the-middle attack vulnerability exists in Siemens SIMATIC STEP 7 TCP port 102, which could be exploited by an attacker to intercept or modify communications...
Siemens SIMATIC STEP 7 TIA Portal Password Hash Algorithm Security Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A security vulnerability exists in Siemens SIMATIC STEP 7 TIA that allows an attacker to exploit the vulnerability to access TIA project files, reconstruct passwords or WEB server passwords...
Siemens SIMATIC STEP 7 Sensitive Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A sensitive information disclosure vulnerability exists in Siemens SIMATIC STEP 7, which allows attackers to exploit the vulnerability to gain access to sensitive information due to the use of an insecure hash...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
CVE-2015-1355
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
Authorization
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...