CVE-2015-1602
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
Information disclosure
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
CVE-2015-1601
CVE-2015-1601 affects Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1. The root cause is a man-in-the-middle vulnerability in network communications (Port 102/TCP) that can allow attackers to intercept or modify transmitted data, potentially exposing sensitive information or enab...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
CVE-2015-1602
Siemens SIMATIC STEP 7 (TIA Portal) v12 and v13 prior to SP1 Upd1 are affected by CVE-2015-1602, which involves storing cleartext passwords in project files, enabling local attackers to reconstruct protection-level and web-server passwords from read files. The issue comprises two related weakness...
KLA10534 Sensitive information obtain vulnerabilities in Siemens SIMATIC STEP
Improper password store and other uncnown vulnerability were found in SIMATIC STEP 7. By exploiting these vulnerabilities malicious users can obtain sensitive information. These vulnerabilities can be exploited remotely via an unknown vectors. Original advisories Siemens advisory Related products...
Siemens SIMATIC STEP 7 (TIA Portal) Detection
Binary data scadaappsiemenstiastep7detect.nbin...
Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836)
Binary data scadasiemenstiamultiplevulnerabilitiesSSA-315836.nbin...
Siemens SIMATIC STEP 7 Sensitive Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A sensitive information disclosure vulnerability exists in Siemens SIMATIC STEP 7, which allows attackers to exploit the vulnerability to gain access to sensitive information due to the use of an insecure hash...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
CVE-2015-1355
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
Authorization
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal (pre-13 SP1) stores device user privileges in project files with insufficient integrity protection, enabling modification of authorization data via a manipulated file and leading to privilege escalation. Mitigation: apply Siemens STEP 7 TIA Portal V13 Service Pac...
CVE-2015-1355
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack...
CVE-2015-1355
Siemens SIMATIC STEP 7 TIA Portal (all versions prior to V13 SP1) is vulnerable due to use of a weak password-hashing algorithm for device user passwords stored in TIA Portal project files. Local users with read access to a project file could potentially reconstruct plaintext passwords. Siemens r...
CVE-2015-1356
Siemens SIMATIC STEP 7 TIA Portal before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file...
PT-2016-14: Information Disclosure in Siemens SIMATIC STEP 7 (TIA Portal)
The specialists of the Positive Research center have detected an Information Disclosure vulnerability in Siemens SIMATIC STEP 7 TIA Portal. Siemens SIMATIC STEP 7 TIA Portal uses an improper format for managing TIA project files during version updates, which makes it easier for local users to...