833 matches found
Authentication Bypass
shiro-spring-boot-web-starter is vulnerable to authentication bypass. An attacker is able to bypass authentication via a malicious HTTP request...
CVE-2020-14022
Ozeki NG SMS Gateway 4.17.1 through 4.17.6 does not check the file type when bulk importing new contacts "Import Contacts" functionality from a file. It is possible to upload an executable or .bat file that can be executed with the help of a functionality E.g. the "Application Starter" module...
Design/Logic Flaw
Ozeki NG SMS Gateway 4.17.1 through 4.17.6 does not check the file type when bulk importing new contacts "Import Contacts" functionality from a file. It is possible to upload an executable or .bat file that can be executed with the help of a functionality E.g. the "Application Starter" module...
CVE-2020-7588
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD&L V8.0, SIMATIC IT LMS All...
CVE-2020-7581
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD&L V8.0, SIMATIC Notifier...
CVE-2020-7581
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD V8.0, SIMATIC Notifier...
CVE-2020-7581
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD&L V8.0, SIMATIC Notifier...
CVE-2020-7581
CVE-2020-7581 affects Siemens/Opcenter components (Discrete/Foundation/Process, Intelligence, Quality, RD&L) and related SIMATIC/Soft Starter/PCS neo, STEP 7, SIMOCODE ES, and Notifier Server. Root cause: an internal component calls a helper binary with SYSTEM privileges during startup via an unq...
PT-2020-6696 · Siemens · Simocode Es +12
Name of the Vulnerable Software and Affected Versions: Opcenter Execution Discrete versions prior to V3.2 Opcenter Execution Foundation versions prior to V3.2 Opcenter Execution Process versions prior to V3.2 Opcenter Intelligence versions prior to V3.3 Opcenter Quality versions prior to V11.3...
CVE-2020-7585
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3, SIMATIC PDM All versions V9.2, SIMATIC STEP 7 V5.X All versions V5.6 SP2 HF3, SINAMICS STARTER containing STEP 7 OEM version All versions V5.4 HF2. A DLL Hijacking...
CVE-2020-7586
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3, SIMATIC PDM All versions V9.2, SIMATIC STEP 7 V5.X All versions V5.6 SP2 HF3, SINAMICS STARTER containing STEP 7 OEM version All versions V5.4 HF2. A buffer overflow...
Code injection
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3, SIMATIC PDM All versions V9.2, SIMATIC STEP 7 V5.X All versions V5.6 SP2 HF3, SINAMICS STARTER containing STEP 7 OEM version All versions V5.4 HF2. A DLL Hijacking...
Buffer overflow
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3, SIMATIC PDM All versions V9.2, SIMATIC STEP 7 V5.X All versions V5.6 SP2 HF3, SINAMICS STARTER containing STEP 7 OEM version All versions V5.4 HF2. A buffer overflow...
CVE-2020-7586
CVE-2020-7586 is a local, heap-based buffer overflow vulnerability affecting Siemens products (SIMATIC PCS 7, PDM, STEP 7, SINAMICS STARTER). The issue allows a local attacker with existing access to cause a DoS and potentially access confidential information due to memory corruption. Root cause ...
CVE-2020-7585
The connected advisory (ICSA-20-161-05) provides concrete details for CVE-2020-7585. A DLL hijacking flaw (Uncontrolled Search Path Element, CWE-427) in Siemens software could allow a local attacker with access to execute code with elevated privileges, affecting: SIMATIC PCS 7 v8.2 and earlier; S...
Security Bulletin: IBM Security Information Queue does not invalidate sessions after logout (CVE-2020-4291)
Summary IBM Security Information Queue ISIQ session identifiers are not properly invalidated upon user logout from ISIQ's web UI. This create opportunities for an attacker to hijack a user session token. As of v1.0.6, ISIQ immediately invalidates the session token when a user logs out...
Unauthorized Access Vulnerability in Gas SCADA System of Shandong Starter Measurement and Control Equipment Co.
The gas transmission and distribution height SCADA system is a large-scale network system. SCADA system of Shandong Starter Measurement and Control Equipment Co., Ltd. has an unauthorized access vulnerability, which can be exploited by an attacker to obtain critical information of the enterprise'...
UBUNTU-CVE-2019-2173
In startActivityMayWait of ActivityStarter.java, there is a possible incorrect Activity launch due to an incorrect permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product:...