Lucene search
+L

1644 matches found

SUSE CVE
SUSE CVE
added 2023/02/15 5:52 a.m.6 views

SUSE CVE-2011-2517

Multiple buffer overflows in net/wireless/nl80211.c in the Linux kernel before 2.6.39.2 allow local users to gain privileges by leveraging the CAPNETADMIN capability during scan operations with a long SSID value...

7.2CVSS6.8AI score0.00377EPSS
SaveExploits0References5
SUSE CVE
SUSE CVE
added 2023/02/15 5:21 a.m.4 views

SUSE CVE-2015-1863

Heap-based buffer overflow in wpasupplicant 1.0 through 2.4 allows remote attackers to cause a denial of service crash, read memory, or possibly execute arbitrary code via crafted SSID information in a management frame when creating or updating P2P entries...

5.8CVSS8.2AI score0.05191EPSS
SaveExploits0References7
SUSE CVE
SUSE CVE
added 2023/02/15 4:56 a.m.4 views

SUSE CVE-2016-8658

Stack-based buffer overflow in the brcmfcfg80211startap function in drivers/net/wireless/broadcom/brcm80211/brcmfmac/cfg80211.c in the Linux kernel before 4.7.5 allows local users to cause a denial of service system crash or possibly have unspecified other impact via a long SSID Information Eleme...

6.1CVSS8.1AI score0.00647EPSS
SaveExploits0References9
SUSE CVE
SUSE CVE
added 2023/02/15 3:51 a.m.7 views

SUSE CVE-2020-36158

mwifiexcmd80211adhocstart in drivers/net/wireless/marvell/mwifiex/join.c in the Linux kernel through 5.10.4 might allow remote attackers to execute arbitrary code via a long SSID value, aka CID-5c455c5ab332...

8.8CVSS7.2AI score0.02209EPSS
SaveExploits0References31
SUSE CVE
SUSE CVE
added 2023/02/15 3:44 a.m.7 views

SUSE CVE-2021-28660

rtwwxsetscan in drivers/staging/rtl8188eu/osdep/ioctllinux.c in the Linux kernel through 5.11.6 allows writing beyond the end of the -ssid array. NOTE: from the perspective of kernel.org releases, CVE IDs are not normally used for drivers/staging/ unfinished work; however, system integrators may...

8CVSS8.2AI score0.01316EPSS
SaveExploits0References34
NVD
NVD
added 2023/02/09 7:15 p.m.30 views

CVE-2023-21429

Improper usage of implict intent in ePDG prior to SMR JAN-2023 Release 1 allows attacker to access SSID...

4CVSS4.2AI score0.00156EPSS
SaveExploits0References1
Prion
Prion
added 2023/02/09 7:15 p.m.19 views

Design/Logic Flaw

Improper usage of implict intent in ePDG prior to SMR JAN-2023 Release 1 allows attacker to access SSID...

1.7CVSS4.2AI score0.00156EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2023/02/09 12:00 a.m.11 views

CVE-2023-21429

Improper usage of implict intent in ePDG prior to SMR JAN-2023 Release 1 allows attacker to access SSID...

4CVSS7AI score0.00156EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2023/02/09 12:00 a.m.39 views

CVE-2023-21429

Improper usage of implict intent in ePDG prior to SMR JAN-2023 Release 1 allows attacker to access SSID...

4CVSS4.6AI score0.00156EPSS
SaveExploits0References1
CVE
CVE
added 2023/02/09 12:00 a.m.59 views

CVE-2023-21429

Vulnerable component: Samsung ePDG. Issue stems from improper usage of implicit intent in ePDG prior to SMR JAN-2023 Release 1, enabling an attacker to access the SSID. Impact is limited to local access (per CVSS) with low confidentiality impact as described in the sources. Remediation: apply Sam...

4CVSS4.1AI score0.00156EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2023/01/20 12:00 a.m.69 views

CVE-2020-22662

CVE-2020-22662 affects a range of Ruckus devices (R310/R500/R600/T300/T301n/T301s, SCG200, SZ-100/SZ-300/vSZ, ZoneDirector 1100/1200/3000/5000) where a remote code execution via command injection can set unauthorized “illegal region codes,” enable illegal frequencies at maximum power, and inflate...

7.5CVSS8AI score0.01255EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2023/01/20 12:00 a.m.11 views

CVE-2020-22662

In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...

8.2AI score0.01255EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2023/01/20 12:00 a.m.39 views

CVE-2020-22662

In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...

8AI score0.01255EPSS
SaveExploits0References2
CNVD
CNVD
added 2023/01/04 12:00 a.m.46 views

Tenda A15 ssid parameter stack overflow vulnerability

Tenda A15 is a WiFi extender from Tenda, China. A stack overflow vulnerability exists in the Tenda A15 ssid parameter, which stems from a lack of length checking of input data in the ssid parameter of /goform/WifiBasicSet, and can be exploited by attackers to execute arbitrary code on the system...

9.8CVSS6.1AI score0.00873EPSS
SaveExploits1References1
NVD
NVD
added 2022/12/30 9:15 p.m.33 views

CVE-2022-47119

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet...

9.8CVSS0.00873EPSS
SaveExploits1References1
CVE
CVE
added 2022/12/30 12:00 a.m.72 views

CVE-2022-47119

CVE-2022-47119 affects the Tenda A15 family. A stack overflow is triggered via the ssid parameter in the /goform/WifiBasicSet API, as described in multiple sources. Reported impact indicates possible arbitrary code execution with high/critical severity (NVD CVSSv3.1: 9.8, NETWORK/LOW/NO PRIVILEGE...

9.8CVSS9.7AI score0.00873EPSS
SaveExploits1References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/12/30 12:00 a.m.7 views

CVE-2022-47119

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet...

7.8AI score0.00873EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2022/12/30 12:00 a.m.10 views

Tenda A15 缓冲区错误漏洞

Tenda A15 is a WiFi extender from Tenda, China. A stack overflow vulnerability exists in the Tenda A15 ssid parameter, which stems from a lack of length checking of input data in the ssid parameter of /goform/WifiBasicSet, and can be exploited by attackers to execute arbitrary code on the system...

9.8CVSS8.1AI score0.00873EPSS
SaveExploits1References2
Cvelist
Cvelist
added 2022/12/30 12:00 a.m.41 views

CVE-2022-47119

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet...

9.9AI score0.00873EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
added 2022/12/30 12:00 a.m.14 views

PT-2022-28021 · Tenda · Tenda Ac15

Name of the Vulnerable Software and Affected Versions: Tenda A15 version 15.13.07.13 Description: A stack overflow issue was discovered via the ssid parameter at the "/goform/WifiBasicSet" API endpoint. Recommendations: For Tenda A15 version 15.13.07.13, avoid using the ssid parameter in the...

9.8CVSS9.4AI score0.00873EPSS
SaveExploits1References2
Rows per page
Query Builder