Schneider Electric Modicon M580 UMAS set breakpoint denial-of-service vulnerability
Summary An exploitable denial-of-service vulnerability exists in the UMAS set breakpoint functionality of the Schneider Electric Modicon M580 Programmable Automation Controller, firmware version SV2.70. A specially crafted UMAS command can cause the device to enter a non-recoverable fault state,...
Schneider Electric Modicon M580 UMAS strategy read information disclosure vulnerability
Summary An exploitable information disclosure vulnerability exists in the UMAS strategy read functionality of the Schneider Electric Modicon M580 Programmable Automation Controller firmware version SV2.70. A specially crafted UMAS command can cause the device to return blocks of the programmed...
Schneider Electric UnityPro PLC simulator remote code execution vulnerability
Summary An exploitable remote code execution vulnerability exists in the UMAS strategy programming functionality of the Schneider Electric Unity Pro L Programming Software PLC Simulator. A specially crafted sequence of UMAS commands sent to the software’s PLC simulator can cause a modified strate...
Carel pCOWeb < B1.2.1 - Cross-Site Scripting Vulnerability
Exploit for hardware platform in category web applications Exploit Title: Carel pCOWeb - Stored XSS Exploit Author: Luca.Chiou Vendor Homepage: https://www.carel.com/ Version: Carel pCOWeb all versions prior to B1.2.1 Tested on: It is a proprietary devices: http://www.carel.com/product/pcoweb-car...
CVE-2019-6806
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus...
Information disclosure
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus...
Information disclosure
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...
CVE-2018-7844
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...
CVE-2018-7848
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus...
Information disclosure
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus...
CVE-2018-7844
CVE-2018-7844 affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. The UMAS read memory block function can disclose plaintext data, including SNMP community strings, when reading memory blocks over Modbus. Exploitation is unauthenticated and feasible against firmware versions ...
CVE-2018-7844
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...
CVE-2019-6806
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus...
CVE-2019-6806
Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs are affected by CVE-2019-6806, a CWE-200 information-exposure vulnerability. The issue stems from UMAS/Modbus read paths that can disclose SNMP information, including read/write/trap SNMP strings, when reading variables in the contr...
CVE-2018-7848
CVE-2018-7848 is an information-disclosure flaw in Schneider Electric Modicon controllers (M580, M340, Quantum, Premium) exploitable via the UMAS strategy read path. A specially crafted UMAS read of the programmed strategy (function code 0x34) can reveal plaintext SNMP community strings and other...
CVE-2018-7848
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus...
Rockwell Automation/Allen-Bradley MicroLogix 1400 SNMP Remote Privilege Escalation
Binary data 70.prm...
CVE-2019-1858
A vulnerability in the Simple Network Management Protocol SNMP input packet processor of Cisco FXOS Software and Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause the SNMP application to leak system memory, which could cause an affected device to restart unexpectedly...
CVE-2019-1858 Cisco FXOS and NX-OS Software Simple Network Management Protocol Denial of Service Vulnerability
A vulnerability in the Simple Network Management Protocol SNMP input packet processor of Cisco FXOS Software and Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause the SNMP application to leak system memory, which could cause an affected device to restart unexpectedly...
CVE-2019-1858
Summary (CVE-2019-1858) : A vulnerability in the SNMP input packet processor on Cisco FXOS Software and Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause the SNMP application to leak system memory, leading to repeated restarts and a DoS condition. Root cause is imprope...