Lucene search
+L

1340 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/15 12:00 a.m.•7 views

CVE-2023-4856: Improper Neutralization of Special Elements used in an OS Command

A format string vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute arbitrary commands on a specific API endpoint...

8.8CVSS6.3AI score0.00665EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/15 12:00 a.m.•7 views

CVE-2023-4855: Improper Neutralization of Special Elements used in an OS Command

A command injection vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user with elevated privileges to execute unauthorized commands via IPMI...

7.2CVSS6.1AI score0.01131EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2024/04/09 12:00 a.m.•6 views

PT-2024-3580

Name of the Vulnerable Software and Affected Versions Lenovo ThinkSystem, ThinkAgile, NeXtScale, and Lenovo CP-CB-10 affected versions not specified SMM/SMM2 and FPC affected versions not specified Description A format string vulnerability was identified in SMM/SMM2 and FPC that could allow an...

9CVSS6.6AI score0.00665EPSS
SaveExploits0References8
CNVD
CNVD
•added 2024/03/21 12:00 a.m.•58 views

Dell PowerEdge Server BIOS Input Validation Error Vulnerability

Dell PowerEdge Server BIOS is a system update driver for the Dell Dell of the United States. The Dell PowerEdge Server BIOS is vulnerable to an input validation error vulnerability that stems from the presence of an SMM communication buffer validation error. An attacker could exploit this...

6.8CVSS6.9AI score0.00233EPSS
SaveExploits0References1
NVD
NVD
•added 2024/03/19 8:15 a.m.•33 views

CVE-2024-25942

Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...

6.8CVSS4.5AI score0.00233EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2024/03/19 7:52 a.m.•36 views

CVE-2024-25942

Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...

4.4CVSS4.9AI score0.00233EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/19 7:52 a.m.•122 views

CVE-2024-25942

Dell PowerEdge Server BIOS is affected by an Improper SMM communication buffer verification vulnerability. The root cause is improper verification in SMM communication buffers, enabling a physically present, high-privilege attacker to cause arbitrary writes to SMRAM. Impact is restricted to integ...

6.8CVSS4.6AI score0.00233EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2024/03/19 7:52 a.m.•26 views

CVE-2024-25942

Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...

4.4CVSS6.7AI score0.00233EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2024/03/19 12:00 a.m.•27 views

PT-2024-21234 · Dell · Dell Poweredge Server Bios

Name of the Vulnerable Software and Affected Versions: Dell PowerEdge Server BIOS affected versions not specified Description: The issue is related to an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability,...

6.8CVSS6.7AI score0.00233EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/19 12:00 a.m.•7 views

CVE-2024-25942: Improper Input Validation

Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...

6.8CVSS6.3AI score0.00233EPSS
SaveExploits0References3
NVD
NVD
•added 2024/03/13 5:15 p.m.•29 views

CVE-2024-0162

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM...

8.8CVSS5.2AI score0.00151EPSS
SaveExploits0References1
Prion
Prion
•added 2024/03/13 5:15 p.m.•30 views

Design/Logic Flaw

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM...

3.5CVSS7AI score0.00151EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/13 4:52 p.m.•89 views

CVE-2024-0173

CVE-2024-0173 concerns Dell PowerEdge Server BIOS and Dell Precision Rack BIOS, where an improper parameter initialization vulnerability could allow a local, low-privilege attacker to read contents of non-SMM stack memory. Affected firmware is BIOS-level, with exploitation requiring local access ...

3.8CVSS4AI score0.00169EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2024/03/13 4:52 p.m.•50 views

CVE-2024-0173

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory...

3.8CVSS4.3AI score0.00169EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2024/03/13 4:41 p.m.•23 views

CVE-2024-0154

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory...

3.8CVSS6.4AI score0.00203EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/13 4:18 p.m.•102 views

CVE-2024-0162

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS are affected by an Improper SMM communication buffer verification vulnerability that enables out-of-bounds reads/writes to SMRAM via a local, low-privilege attacker. Affected components are the BIOS implementations for Dell PowerEdge Server ...

8.8CVSS5.2AI score0.00151EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2024/03/13 4:18 p.m.•41 views

CVE-2024-0162

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM...

5.3CVSS5.5AI score0.00151EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2024/03/13 4:18 p.m.•22 views

CVE-2024-0162

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM...

5.3CVSS5.2AI score0.00151EPSS
SaveExploits0References1
NVD
NVD
•added 2024/03/13 4:15 p.m.•27 views

CVE-2024-0161

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...

8.4CVSS7AI score0.00204EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/13 4:04 p.m.•79 views

CVE-2024-0161

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS are affected by an improper SMM communication buffer verification vulnerability, enabling a local, low-privileged attacker to potentially perform arbitrary writes to SMRAM. The issue stems from a faulty SMM buffer validation in the BIOS/firm...

8.4CVSS6.9AI score0.00204EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder