Lucene search
+L

328 matches found

Tenable Nessus
Tenable Nessus
•added 2019/05/21 12:00 a.m.•13 views

Siemens SINAMICS G120 CU250S-2 VECTOR Drive

Binary data 230.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/21 12:00 a.m.•21 views

Siemens SINAMICS G120 CU240E-2 PN Drive

Binary data 227.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/21 12:00 a.m.•14 views

Siemens SINAMICS G120D CU250D-2 PN Drive

Binary data 229.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/21 12:00 a.m.•18 views

Siemens SINAMICS G120C PN Drive

Binary data 223.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/21 12:00 a.m.•15 views

Siemens SINAMICS G120D CU240D-2 PN Drive

Binary data 225.prm...

7.3AI score
SaveExploits0
NVD
NVD
•added 2019/05/14 8:29 p.m.•33 views

CVE-2019-6574

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...

7.5CVSS7.5AI score0.0185EPSS
SaveExploits0References1
NVD
NVD
•added 2019/05/14 8:29 p.m.•40 views

CVE-2019-6578

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...

7.5CVSS7.4AI score0.01568EPSS
SaveExploits0References2
Prion
Prion
•added 2019/05/14 8:29 p.m.•24 views

Denial of service

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...

5CVSS7.3AI score0.01568EPSS
SaveExploits0References2
Prion
Prion
•added 2019/05/14 8:29 p.m.•44 views

Code injection

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...

5CVSS7.5AI score0.0185EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/05/14 7:54 p.m.•50 views

CVE-2019-6578

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...

7.3AI score0.01568EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2019/05/14 7:54 p.m.•42 views

CVE-2019-6574

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...

7.5AI score0.0185EPSS
SaveExploits0References1
CVE
CVE
•added 2019/05/14 7:54 p.m.•74 views

CVE-2019-6574

CVE-2019-6574 affects Siemens SINAMICS PERFECT HARMONY GH180 (NXG I/NXG II) with MLFBs 6SR2...-, 6SR3...-, 6SR4...- (options G21–G46). Root cause: improperly configured Parameter Read/Write execution via Fieldbus network, enabling a remote attacker with network access to restart the controller an...

7.5CVSS7.5AI score0.0185EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2019/05/14 7:54 p.m.•72 views

CVE-2019-6578

CVE-2019-6578 affects Siemens SINAMICS PERFECT HARMONY GH180 drives (NXG I/II) with option G28, where an attacker with network access can trigger a denial-of-service via uncontrolled resource consumption on the Ethernet Modbus interface. No privileges or user interaction are required; impact is a...

7.5CVSS7.3AI score0.01568EPSS
SaveExploits0References2Affected Software1
CNVD
CNVD
•added 2019/05/14 12:00 a.m.•16 views

Multiple Siemens Products Input Validation Error Vulnerability

Siemens SINAMICS PERFECT HARMONY GH180 is a high-voltage AC frequency converter from Siemens, Germany. An input validation error vulnerability exists in multiple Siemens products. The vulnerability originates from a network system or product that does not properly validate input data. An attacker...

7.5CVSS6.9AI score0.01568EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2019/05/14 12:00 a.m.•5 views

PT-2019-2101

Name of the Vulnerable Software and Affected Versions SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28 SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28 Descriptio...

7.5CVSS0.01568EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2019/05/14 12:00 a.m.•6 views

PT-2019-2109

Name of the Vulnerable Software and Affected Versions SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46 SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-,...

7.5CVSS0.0185EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/14 12:00 a.m.•8 views

CVE-2019-6574: Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...

7.5CVSS5.9AI score0.0185EPSS
SaveExploits0References2
CNVD
CNVD
•added 2019/05/14 12:00 a.m.•64 views

Multiple Siemens Products Access Control Error Vulnerabilities

Siemens SINAMICS PERFECT HARMONY GH180 is a high-voltage AC frequency converter from Siemens Germany. An access control error vulnerability exists in several Siemens products. The vulnerability stems from a network system or product that does not properly restrict access to resources from...

7.5CVSS2.3AI score0.0185EPSS
SaveExploits0References1
ICS
ICS
•added 2019/05/14 12:00 a.m.•87 views

ICSA-19-134-05 Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...

7.5CVSS7.7AI score0.01568EPSS
SaveExploits0References9
ICS
ICS
•added 2019/05/14 12:00 a.m.•116 views

ICSA-19-134-06 Siemens SINAMICS PERFECT HARMONY GH180 Fieldbus Network

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Fieldbus Network Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a...

7.5CVSS7.8AI score0.0185EPSS
SaveExploits0References9
Rows per page
Query Builder